ABB CV-1 Manuals

2 pdf manual(s) ABB CV-1 for free download (Document Types: Instruction leaflet)

Document Preview & Text Transcription

ABB Power T&D Company Inc. Power Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet All possible contingencies which may arise during installation, operation or maintenance, and all details and variations of this equipment do not purport to be covered by these instructions. If further information is desired by purchaser regarding this particular installation, operation or maintenance of this equipment, the local ABB Power T&D Company Inc. representative should be contacted. Printed in U.S.A. I.L. 41-201S Supersedes I.L. 41-201R, Dated April 1995 Type CV Voltage Relay Effective: January 1997 ( | ) Denotes Change Since Previous Issue ! CAUTION Before putting relays into service, remove all blocking which may have been inserted for the purpose of securing the parts during ship- ment, make sure that all moving parts operate freely, inspect the contacts to see that they are clean and close properly, and operate the relay to check the settings and electrical con- nections. 1. APPLICATION The Type CV Relays are single-phase induction disc type relays operating either on under or overvoltage or both. These relays are applied as a voltage fault detector operating in conjunction with other protec- tive relays. The relays are also used as timing devices for various automatic operations. 2. CONSTRUCTION AND OPERATION The types CV-1, CV-2 CV-4, CV-5, CV-6, and CV-7 relays consist of a voltage unit and an indicating con- tactor switch (ICS). The principal component parts of the relay and their location are shown in Figures 1, 2, and 3. The Type CV-8 relay in addition to the above compo- nents also has a capacitor which is series tuned with the main coil of the electromagnet. This tuned circuit offers a low impedance to fundamental current and a high impedance to third harmonic currents. Hence, the relay has a low pickup value for fundamental volt- age and a much higher value of pickup for third har- monic voltage. At rated voltage the electromagnet is saturated causing the circuit to be detuned. The impedance of the circuit is increased and limits the fundamental current to a safe value. 2.1. Voltage Unit (CV) The overvoltage unit operates on the induction disc principle. A main tapped coil located on the center leg of an “E” type laminated structure produces a flux which divides and returns through the outer legs. A shading coil causes the flux through the left leg (front view) to lag the main pole flux. The out-of-phase fluxes thus produced in the air gap causes a contact closing torque. The undervoltage unit operates on the same princi- ple as the overvoltage unit except the shading coil is on the right leg (front view). This causes the out-of- phase fluxes to produce a contact opening torque. This instruction leaflet applies to the following types of relay: CV-1 Long Time Undervoltage Relay CV-2 Short Time Undervoltage Relay CV-4 Long Time Overvoltage Relay CV-5 Short Time Overvoltage Relay CV-6 Long Time Over or Undervoltage Relay CV-7 Short Time Over or Undervoltage Relay CV-8 Low Voltage Pickup Overvoltage Relay I.L. 41-201S 3 2.2. Indicating Contactor Switch (ICS) The indicating contactor switch is a small dc oper- ated clapper type device. A magnetic armature, to which leaf-spring mounted contacts are attached, is attracted to the magnetic core upon energization of the switch. When the switch closes, the moving con- tacts bridge two stationary contacts, completing the trip circuit. Also during this operation, two fingers on the armature deflect a spring located on the front of the switch, which allows the operation indicator tar- get to drop. The target is reset from the outside of the case by a push-rod located at the bottom of the case. The front spring, in addition to holding the target, pro- vides restraint for the armature and thus controls the pickup value of the switch. 3. CHARACTERISTICS The CV-1 and CV-2 undervoltage relays, CV-4 and CV-5 overvoltage relays, and CV-6 and CV-7 over or undervoltage relays are available in the following voltage ranges: 3.1. CV-1 and CV-2 Undervoltage Relay – CV-4 and CV-5 Overvoltage Relays Tap value voltage is the minimum voltage required to just close the relay contacts. At this value of voltage, the moving contacts will leave the backstop of the dial and move to close the front contacts. Normal operation of the two relays is such that the CV-1 and CV-2 under-voltage relay will open its contacts with application of voltages greater than tap value volt- age, while the CV-4 and CV-5 overvoltage relay closes its contacts with voltages greater than tap value voltage. Thus, the operating curves of Figures 11 and 12 of the undervoltage relays apply when the voltage is originally higher than tap value voltage and is suddenly reduced to a value shown on the curves. The operating curves of Figures 13 and 14 of the overvoltage relays apply when the voltage is initially below tap value voltage and is suddenly raised to a value shown on the curves. 3.2. CV-6 and CV-7 Over or Undervoltage Relays Tap value voltage is the value of voltage at which the stationary front contact closes. The stationary back contact will close within 5% of this value. When the relay is used as an overvoltage relay, the moving contact is made with the stationary back con- tact for values of applied voltage less than tap value Range Taps 55-140 110-280 55 64 70 82 93 105 120 140 110 128 140 164 186 210 240 280 Figure 3. Indicating Contactor Switch (ICS)

Document Preview & Text Transcription

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet All possible contingencies which may arise during installation, operation or maintenance, and all details and variations of this equipment do not purport to be covered by these instructions. If further information is desired by purchaser regarding this particular installation, operation or maintenance of this equipment, the local ABB Power T&D Company Inc. representative should be contacted. Type CV Voltage Relay Class 1E Applications Effective: November 1999 Supersedes I.L. 41-201.4G, dated January 1997 ( ) Denotes changes since previous issue CONTENTS This instruction leaflet applies to the follow- ing types of relays: • CV-1 Long Time Undervoltage Relay • CV-2 Short Time Undervoltage Relay • CV-4 Long Time Overvoltage Relay • CV-5 Short Time Overvoltage Relay • CV-6 Long Time Over or Undervoltage Relay • CV-7 Short Time Over or Undervoltage Relay • CV-8 Low Voltage Pickup Overvoltage Relay ! CAUTION Before putting relays into service, remove all blocking which may have been inserted for the purpose of securing the parts during ship- ment, make sure that all moving parts operate freely, inspect the contacts to see that they are clean and close properly, and operate the relay to check the settings and electrical con- nections. 1.0 APPLICATIONS These relays have been specially designed and tested to establish their suitability for Class 1E appli- cations in accordance with the ABB Power T&D Com- pany program for Class 1E Qualification Testing as detailed in bulletin STR-1. “Class 1E” is the safety classification of the electric equipment and systems in nuclear power generating stations that are essential to emergency shutdown of the reactor, containment isolation, cooling of the reac- tor, and heat removal from the containment and reac- tor, or otherwise are essential in preventing significant release of radioactive material to the environment. The type CV relays are single-phase induction-disc type relays operating either on under or over voltage or both. These relays are applied as a voltage fault detector operating in conjunction with other protective relays. The relays are also used as timing devices for various automatic operations. 2.0 CONSTRUCTION and OPERATION The types CV-1, CV-2, CV-4, CV-5, CV-6 and CV-7 relays consist of a voltage unit, an auxiliary telephone type relay and an indicating contactor switch (ICS). The principal component parts of the relay and their location are shown in Figure 1 (page 2). The type CV-8 relay in addition to the above compo- nents also has a capacitor which is series tuned with the main coil of the electromagnet. This tuned circuit 41-201.4H 41-201.4H CV Voltage Relay Class 1E 2 2.1. VOLTAGE UNIT (CV) The overvoltage unit operates on the induction-disc principle. A main tapped coil located on the center leg of an “E” type laminated structure produces a flux which divides and returns through the outer legs. A shading coil causes the flux through the left leg (front view) to lag the main pole flux. This causes the out- of-phase fluxes to produce a contact opening torque. The undervoltage unit operates on the same princi- ple as the overvoltage unit except the shading coil is on the right leg (front view). This causes the out-of- phase fluxes to produce a contact opening torque. 2.2. INDICATING CONTACTOR SWITCH UNIT (ICS) The dc indicating contactor switch is a small clapper type device. A magnetic armature, to which leaf- spring mounted contacts are attached, is attracted to the magnetic core upon energization of the switch. When the switch closes, the moving contacts bridge offers a low impedance to fundamental current and a high impedance to third harmonic currents. Hence, the relay has a low pickup value for fundamental volt- age and much higher value of pickup for third har- monic voltage. At rated voltage the electromagnet is saturated causing the circuit to be detuned. The impedance of the circuit is increased and limits the fundamental current to a safe value. Figure 2 and 3 show CV-8 relays with adjustable pickup. Internal schematics are shown in Figures 4 through 10 (beginning on page 9). Photo not available at this time Figure 1: Type CV Relay Without FT11 Case Figure 2: 199 Volt Type CV-8 Relay With Adjustable Pickup Without FT11 Case Figure 3: 67 Volt Type CV-8 Relay with Adjustable Pickup without FT-21 Case CV Voltage Relay Class 1E 41-201.4H 3 two stationary contacts, completing the trip circuit. For double circuit closing contacts, the moving con- tacts bridge three stationary contacts. Also during this operation two fingers on the armature deflect a spring located on the front of the switch, which allows the operation indicator target to drop. The same unit is also used as a Trip Indicator (OI) except there are no stationary contacts, or the sta- tionary contacts are moved upward out of reach of the moving contacts. The front spring in addition to holding the target, pro- vides restraint for the armature and thus controls the pickup value of the switch. 3.0 CHARACTERISTICS The low pickup CV-8 Overvoltage Relay is available with the following continuous voltage ratings. The minimum 60 Hertz voltage to just close the CV-8 contacts is typically 8% of the continuous voltage. Typical operating times of the type CV-8 relay are shown on Figure 11 (page 13). An adjustable 5.4 to 20 volt relay with a 67 volt continuous and a 16 to 40 volt relay with a continuous of 199 volts is also avail- able. However, the operate times for the adjustable CV-8 relay will differ from Figure 11 and will depend on the pickup setting. Figure 12 (page 14) applies when the resistor is set for maximum pickup. Pickup changes with frequency as shown in Figure 13 (page 15). The CV-1 and CV-2 Undervoltage Relays, CV-4 and CV-5 Overvoltage Relays, and CV-6 and CV-7 Over or Under voltage Relays are available in the following voltage ranges. 3.1. CV-1 AND CV-2 UNDERVOLTAGE RELAYS CV-4 AND CV-5 OVERVOLTAGE RELAYS Tap value voltage is the minimum voltage required to just close the relay contacts. At this value of voltage, the moving contacts will leave the backstop of the time dial and move to close the front contacts. Nor- mal operation of the two relays is such that the CV-1 and CV-2 undervoltage relay will open its contacts with application of voltages greater than tap value voltage, while the CV-4 and CV-5 overvoltage relay closes its contacts with voltages greater than tap value voltage. Thus, the operating curves of Figures 14 and 15 (page 16) of the undervoltage relays apply when the voltage is originally higher than tap value voltage and is suddenly reduced to a value shown on the curves. The operating curves of Figures 16 and 17 (page 19) of the overvoltage relays apply when the voltage is initially below tap value voltage and is suddenly raised to a value shown on the curves. 3.2. CV-6 AND CV-7 OVER OR UNDERVOLTAGE RELAYS Tap value voltage is the value of voltage at which the stationary front contact closes. The stationary back contact will close within 5% of this value. When the relay is used as an overvoltage relay, the moving contact is made with the stationary back con- tact for values of applied voltage less than tap value voltage. With application of voltages greater than tap value voltage, the moving contact moves to close the front contact in a time as shown by the right-hand curves of either Figures 18 or 19 (page 20). When the relay is used as an undervoltage relay, the moving contact is made with the stationary front con- tact for values of applied voltage greater than tap value voltage. With the application of voltages less than tap value voltage, the moving contact moves to close the back contact in a time as shown on the left- hand curves of either Figures 18 or 19 (page 20). 3.2.1. Auxiliary Relays (T) Power Requirements Per Unit: 1.3 watts at 48 volts dc 3.3 watts at 125 volts dc Operate Time Pick Up: 3 to 6 milliseconds Drop Out: 90 to 130 milliseconds Contact Rating: A. 20 amperes noninterrupting for less than 200 milliseconds B. 1.3 amperes resistive at 125Vdc C. Will control MG-6, SG, or AR relays at 125Vdc Type Relay 2 Minute Rating 67 volts 199 volts 140 volts 300 volts Range Taps 55-140 110-280 55 110 64 128 70 140 82 164 93 186 105 210 120 240 140 280 41-201.4H CV Voltage Relay Class 1E 4 3.2.2. Trip Circuit The main contacts will close 30 amperes at 250 volts dc and the seal-in contacts of the indicating contactor switch will carry this current long enough to trip a cir- cuit breaker. 3.2.3. Trip Circuit Constants Indicating Contactor Switch Coil, or Indicator Coil. 3.3. ENERGY REQUIREMENTS The 60 Hz burdens of the CV-1, CV-2, CV-4, CV-5, CV-6, CV-7 relays at rated voltage are as follows: (For 50 Hz, multiply volt-amperes by 1.18, multiply watts by 1.38.) The 50 Hz and 60 Hz burdens of the CV-8 relays at continuous voltage do not exceed the following: 4.0 SETTINGS 4.1. CV UNIT The setting of the CV unit can be defined either by tap setting and time dial position or by tap setting and a spe- cific time of operation at some percentage of tap value voltage (e.g. on CV-4 120 tap setting, 2 time dial position or 120 tap setting, 12 seconds at 140 percent of tap value voltage). To provide selective circuit breaker operation, a minimum coordinating time of 0.3 seconds plus circuit breaker time is recommended between the relay being set and the relays with which coordination is to be effected. The nylon screw on the terminal plate holds the tap plate in position when taps are being changed. To use the position on the terminal plate in which the nylon screw is used, remove the nylon screw and place it in one of the unused holes. Then remove the tap screw and insert it in the terminal plate hole. 4.2. CV-8 SETTINGS The CV-8 relay has no taps. Its minimum pickup of approximately 8% of continuous voltage is set by adjusting the restraint spring. For this setting, the adjustable resistor, where used, should be shorted out. Where the resistor is used, the pickup setting can be adjusted from approximately 8% to 30% of the continu- ous voltage rating. This setting is made by adjusting the resistor. Note, however, that the CV-8 time curves shown in Figure 11 (page 13) apply only when the resistor is shorted out. Timing tests should be con- ducted after the resistor is used to change the pickup. This will verify proper coordination time for the desired pickup setting. Figure 12 (page 14) shows operate time when the resistor is set for maximum pickup. 4.3. INSTANTANEOUS RECLOSING The factory adjustment of the voltage unit contacts provides a contact follow. Where circuit breaker reclos- ing will be initiated immediately after a trip by the over voltage contact, the time of the opening of the contacts should be a minimum. This condition is obtained by loosening the stationary contact mounting screw, removing the contact plate and then replacing the plate with the bent end resting against the contact spring. Ampere Pickup Ohms dc Resistance 0.2 1.0 2.0 8.5 0.37 0.10 Rated ∆ Voltage Taps 120 Volt Relay 240 Volt Relay Volt- Amps Power Factor Watts 120 or 240 Volts 55 64 70 82 93 105 120 140 110 128 140 164 186 210 240 280 10.0 7.0 5.8 4.0 3.1 2.4 1.8 1.3 .38 .35 .34 .33 .31 .29 .28 .26 3.8 2.5 2.0 1.3 1.0 .7 .5 .3 ∆ These relays will continuously withstand either 110% of rated volt- age or tap value voltage, whichever is higher. Continuous Voltage Range Setting Applied Voltage VA Power Factor Watts 67 5.4 to 20V 5.4 20 67 67 30 15 .342 10 199 16 to 40V 16 40 199 199 30 20 .342 10 The CV-8 short time (15 seconds) rating is 240V and 510V respectively for the 67 and 199V relays.