ABB REG615 Manuals

2 pdf manual(s) ABB REG615 for free download (Document Types: Product manual, Applications manual)

ABB REG615 Product manual Main Page Preview

Product manual [PDF] (76 pages)

  • Updated: 22.07.2026

Document Preview & Text Transcription

Relion® 615 series Generator and Interconnection Protection REG615 Product Guide Contents 1. Description.....................................................................3 2. Standard configurations................................................. 3 3. Protection functions........................................................9 4. Application..................................................................... 9 5. Supported ABB solutions............................................. 15 6. Control......................................................................... 16 7. Measurements............................................................. 17 8. Power quality................................................................17 9. Disturbance recorder....................................................17 10. Event log.....................................................................17 11. Recorded data............................................................ 18 12. Condition monitoring .................................................. 18 13. Trip-circuit supervision.................................................18 14. Self-supervision...........................................................19 15. Fuse failure supervision............................................... 19 16. Access control............................................................ 19 17. Inputs and outputs...................................................... 19 18. Station communication................................................20 19. Technical data.............................................................25 20. Local HMI....................................................................61 21. Mounting methods...................................................... 62 22. Relay case and plug-in unit......................................... 62 23. Selection and ordering data.........................................62 24. Accessories and ordering data.................................... 63 25. Tools...........................................................................64 26. Cyber security............................................................. 65 27. Terminal diagrams.......................................................66 28. Certificates.................................................................. 69 29. References..................................................................69 30. Functions, codes and symbols....................................70 31. Document revision history........................................... 74 Disclaimer The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility for any errors that may appear in this document. © Copyright 2018 ABB. All rights reserved. Trademarks ABB and Relion are registered trademarks of the ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders. Generator and Interconnection Protection 1MRS758279 B REG615 Product version: 5.0 FP1 2 ABB 1. Description REG615 is a dedicated generator and interconnection protection relay designed for the different power generation applications. REG615 is available in three standard configurations denoted A, C and D. Standard configuration A is intended for the interconnection protection, control, measurement and supervision of the common point of coupling distributed power generation into the utility network. Standard configurations C and D are designed for the protection, control, measurement and supervision of small or medium size generators used in diesel, gas, hydroelectric, combined heat and power (CHP), and steam power plants. REG615 is a member of ABB’s Relion® product family and part of its 615 protection and control product series. The 615 series protection relays are characterized by their compactness and withdrawable unit design. Re-engineered from the ground up, the 615 series has been designed to unleash the full potential of the IEC 61850 standard for communication and interoperability between substation automation devices. Once the standard configuration relay has been given the application-specific settings, it can directly be put into service. The generator protection relay provides main protection for small size power generators. The generator protection relay is also used as back-up protection for medium size generators in power applications, where an independent and redundant protection system is required. The interconnection protection relay provides main protection fulfilling the grid codes to connect distributed generation with the power grid. The 615 series relays support a range of communication protocols including IEC 61850 with Edition 2 support, process bus according to IEC 61850-9-2 LE, IEC 60870-5-103, Modbus® and DNP3. Profibus DPV1 communication protocol is supported by using the protocol converter SPA-ZC 302. 2. Standard configurations REG615 is available in three alternative standard configurations. The standard signal configuration can be altered by means of the signal matrix or the graphical application functionality of the Protection and Control IED Manager PCM600. Further, the application configuration functionality of PCM600 supports the creation of multi-layer logic functions using various logical elements, including timers and flip-flops. By combining protection functions with logic function blocks, the relay configuration can be adapted to user- specific application requirements. The protection relay is delivered from the factory with default connections described in the functional diagrams for binary inputs, binary outputs, function-to-function connections and alarm LEDs. Some of the supported functions in REG615 must be added with the Application Configuration tool to be available in the Signal Matrix tool and in the relay. The positive measuring direction of directional protection functions is towards the busbar. Generator and Interconnection Protection 1MRS758279 B REG615 Product version: 5.0 FP1 Issued: 2018-06-06 Revision: B ABB 3 Io>> 51N-2 ARC 50L/50NL Uo> 59G 3Ith>F 49F 3I>>> 50P/51P 3I2f> 68 I2> 46 3I>/Io>BF 51BF/51NBF 3I>>→ 67-2 3I>→ 67-1 TCS TCM OPTS OPTM 2× MCS 3I MCS 3I FUSEF 60 CBCM CBCM INTERCONNECTION PROTECTION RELAY STANDARD CONFIGURATION PROTECTION LOCAL HMI R L Clear ESC I O Configuration A System HMI Time Authorization R L Clear ESC I O U12 0. 0 kV P 0.00 kW Q 0.00 kVAr IL2 0 A A Io Io REG615 A ALSO AVAILABLE - Disturbance and fault recorders - Event log and recorded data - High-Speed Output module (optional) - Local/Remote push button on LHMI - Self-supervision - Time synchronization: IEEE 1588 v2, SNTP, IRIG-B - User management - Web HMI U2> 47O- U1< 47U+ 3I 3I UL1, L2, L3 Io 3× Q>→, 3U< 32Q, 27 P>/Q> 32R/32O 2× 2× Master Trip Lockout relay 94/86 Io>IEF→ 67NIEF Io>→ 67N-1 Io>>→ 67N-2 2× 2× 3U< 27 3U> 59 U/f<, df/dt 81 2× 2× 2× 2× 6× 3× U12 Uo U12 UL1, L2, L3 Io 2×RTD 1×mA MAP MAP 18× 3× Master Trip Lockout relay 94/86 3× 2× COMMUNICATION Protocols: IEC 61850-8-1/-9-2LE Modbus® IEC 60870-5-103 DNP3 Interfaces: Ethernet: TX (RJ45), FX (LC) Serial: Serial glass fiber (ST), RS-485, RS-232 Redundant protocols: HSR PRP RSTP CONDITION MONITORING AND SUPERVISION OR AND 2× Object Ctrl 2) Ind 3) CB DC ES 1) Check availability of binary inputs/outputs from technical documentation Control and indication function for primary object Status indication function for primary object 2) 3) CONTROL AND INDICATION 1) MEASUREMENT - I, U, Io, Uo, P, Q, E, pf, f - Limit value supervision - Load profile record - RTD/mA measurement (optional) - Symmetrical components - Frequency adaptivity 4 5 Analog interface types 1) Current transformer Voltage transformer 1) Conventional transformer inputs 1 - 2 3 1 2 SYNC 25 PQM3U PQM3V PQMU PQMV PQM3I PQM3I PQUUB PQVUB REMARKS Optional function No. of instances Alternative function to be defined when ordering OR Io/Uo Calculated value 3× UL1, L2, L3 Io GUID-608806E0-EC45-49E7-BBBB-3FD20DD5D84C V1 EN Figure 1. Functionality overview for standard configuration A Generator and Interconnection Protection 1MRS758279 B REG615 Product version: 5.0 FP1 4 ABB

Document Preview & Text Transcription

— RELION® 615 SERIES Generator and Interconnection Protection REG615 Application Manual Document ID: 1MRS758272 Issued: 2018-12-20 Revision: B Product version: 5.0 FP1 © Copyright 2018 ABB. All rights reserved Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. Trademarks ABB and Relion are registered trademarks of the ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders. Warranty Please inquire about the terms of warranty from your nearest ABB representative. www.abb.com/relion