ABB S300RPTU Manuals
1 pdf manual(s) ABB S300RPTU for free download (Document Types: Operation & user’s manual)
ABB S300RPTU Operation & user’s manual [PDF] (12 pages)
- Identifier: id-1457567
- Brand: ABB
- Device: ABB S300RPTU Test Equipment
- Type: Operation & user’s manual, PDF
- Key Aspects: Troubleshooting Information, Control Panel and Interface Navigation, Unpacking and Inspection Guidelines
- UPD Date: 22.08.2026
- Source File: 1540874.pdf
- Pages: 12
- Description: Usage and setup manual for the ABB S300RPTU.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 Esc Ok D300-03-00 8 7 6 5 4 3 2 Connection failed ** Retry? ** Device is: conventional Type - - Class: ------------ Detector -¯ Sensor CONTAMINATED Service Chamber FAULTY Replace Unit Reading Optical XX % Thermal XX % ACQUIRE 1 Detector Settings Last 2 Detector Read % Dirty 1234567890 OK OK OK Detector Data Corrupted Device Information Missing Attempting Connection LINK?...>END Device Address XX Esc Esc Esc USERS GUIDE FOR S300RPTU REMOTE PROGRAMMING TEST TOOL AND S300SAT SATELLITE RELAY DEVICE INTRODUCTION The S300RPTU Remote Programming and Test Tool is designed for communication with System Sensor 300 series detectors, permitting access to various functions and logs within the detectors. Communication is achieved through the detector’s indicator LED, and uses one of two methods: 1. Via an LED and Opto-diode built in to the S300RPTU, for close range (approximately 30mm) communication. This allows direct communication via the detector LED indicator. 2. Using radio communication via an S300SAT which can be clipped to the detector using proprietary access poles, allowing a range up to 4.5m. The S300RPTU is a menu driven device. With reference to figure 1, the controls for navigating through the menus are as follows: (1) On/Off Switch (2) Up/Down Arrows - to scroll through menus (3) OK button - Select required function (4) Esc - Returns to the previous menu POWER ON When the S300RPTU is turned on, the screen shown left will be displayed for approximately 5 seconds, and then will be replaced by the first of the main menu screens. MAIN MENU There are six main menu items as follows: Reads the settings previously programmed into the detector being accessed including sensitivity, address, device type, LED operation and service date. Refer to section 2. Displays the information acquired from the last detector read. Refer to section 2. Programmes new settings such as address, sensitivity and mode of LED operation into the detector. Refer to section 3. Checks that maintenance has been satisfactory, and if OK programmes the current date into the detector as the new service date. Refer to section 4. Performs a detector Alarm Test. Refer to section 5. Allows the user to set the S300RPTU tool to suit requirements, including the tool operating language and communication method. Refer to section 1. Use the up/down arrow buttons to adjust screen intensity to suit then press OK to confirm setting Use the up/down arrow buttons to display either communication via the RPTU LED or the S300SAT, then press OK to confirm setting. Date is displayed as - Day/Month/Year (Based on GMT) Press OK to confirm Use the up/down arrows to display the required language to be used by the S300RPTU, and then press OK to confirm setting The S300SAT can be set to one of 16 addresses to prevent cross talk if more than one is to be used on a site. Use the up/ down arrows to select the relevant address (00-15) then press OK to confirm setting. Note that only one new setting can be made each time the RPTU settings screen is accessed. For each new setting, the S300RPTU will display the ready screen as follows for a few seconds, then return to the “RPTU Settings” screen. The exception to this is the S300SAT address screen, where the RPTU will briefly display “Attempting Connection” before the ready screen appears. 1: S300RPTU AND S300SAT SET UP Prior to any communications with detectors, it is necessary to configure the S300RPTU and S300SAT. This procedure should only need to be carried out once, the settings then being retained until changed via this screen. During the set-up procedure, ensure that only one S300RPTU and S300SAT pair are switched on within a 10m area. Switch on both the S300 RPTU and S300SAT. Scroll down through the main menu screens to select “RPTU Settings”. This gives access to set-up screens as follows: 2: ACQUIRE DETECTOR SETTINGS AND LAST DETECTOR READ Except where indicated, the same operating screens apply to both acquisition of the detector settings and the display of information from the last detector read: Displays Detector Type Code: A = Conventional EN54 Standard, B = Conventional NF (AFNOR), C = Special Displays Detector Type: Thermal, Optical or Opto-Thermal Displays Detector Address (00 to 99) Service information - This screen is only displayed for Optical and Photo- Thermal detectors. Displays the current Chamber / Sensor values. For an optical or thermal detector, the optical or thermal sensor reading only will be displayed as applicable. For photo-thermal detectors both readings will be shown. Continued overleaf Detector Data Corrupted, Return detector to supplier for reprogramming. The S300RPTU will automatically display the relevant screen. In normal conditions with no smoke present, the “% Dirty screen” will be displayed, giving an indication of the level of contamination in the detector chamber. If the detector has reached it’s drift compensation limit and needs cleaning the “Sensor Contaminated” screen will be shown, and if faulty the “Chamber Faulty” screen will be shown. Figure 1: S300RPTU Figure 2: S300RPTU Batteries 3 x 1.5V LR03 (AAA) Batteries Required. RPTU 6 Settings LCD 6.1 Intensity RPTU 6.2 Set LINK mode Read 6.3 Current Date Set Link Via S300SAT Set 6.5 S300SAT Address Set 6.4 RPTU Language Current Date dd/mm/yy SAT Address set to: XX OK Language set to: English *** Ready *** OK 1234567 Detector incompatible with S300RPTU. Note: 1. Last Detector Read Detector information is only displayed if a successful “Aquire Detector Settings” has previously been run. 2. When the S300RPTU is switched off, the Last Detector Read data is lost. Series 300 RPTU - v.1.5 *** READY *** ACQUIRE 1 Detector Settings Last 2 Detector Read Write 3 Detector Settings Write 4 NEW Service Date Alarm 5 Test Press OK x 2 RPTU 6 Settings I56-1720-003EN
Similar Manuals in the Test Equipment Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Hickok AUTO WAVE II |
AUTO WAVE II (Test Equipment ePDF User Guide, #BMP1K7) |
28 | 550 | 132 | 04-07-2026 | view all manuals | |
Rohde & Schwarz HMO1202 Series |
Rohde & Schwarz Test Equipment Operation & user’s manual (File: PDF, 11-08-2026) |
72 | 980 | 245 | 11-08-2026 | view all manuals | |
YOKOGAWA AQ1215A |
YOKOGAWA AQ1215A Guide (Operation & user’s manual), @OSC1UL |
282 | 31 | 6 | 08-06-2026 | view all manuals | |
Dillon Quantrol AFG Series |
PDF Guide (@J1981U), Dillon Quantrol AFG Series Test Equipment (04-06-2026) |
40 | 513 | 103 | 04-06-2026 | view all manuals | |
Elektro-Automatik ELR 9000 HP |
Elektro-Automatik Industrial Electrical Operating manual (File: PDF, 20-03-2026) |
189 | 506 | 87 | 20-03-2026 | view all manuals | |
SKF TKED 1 |
SKF Test Equipment User manual manual (File: PDF, 04-08-2026) |
12 | 721 | 152 | 04-08-2026 | view all manuals |