Absolute Process Instruments APD 4008 Manuals
1 pdf manual(s) Absolute Process Instruments APD 4008 for free download (Document Types: Quick start manual)
Absolute Process Instruments APD 4008 Quick start manual [PDF] (3 pages)
- Identifier: id-2242260
- Brand: Absolute Process Instruments
- Device: APD 4008 Transmitter
- Type: PDF
- Key Aspects: Product Performance Metrics, Component Longevity Optimization, Periodic Inspection Checklists
- UPD Date: 12.03.2026
- Source File: 2045372.pdf
- Pages: 3
- Description: Technical operation manual for the Absolute Process Instruments APD 4008.
Click to expand and read text
Potentiometer Input to DC Transmitters, Isolated, Field Rangeable APD 4008 Input: 100 Ω to 1 MΩ Potentiometers, 0 to 90% Offset Output: 0-1 V to ±10 VDC, or 0-2 mA to 20 mADC O One Minute Setup for Hundreds of I/O Ranges O External Switches & Table for Range Selection O Removable Plugs for Faster Installation O Full 1200 V Input/Output/Power Isolation O Input and Output LoopTracker® LEDs O Functional Output Test Button O Selectable Sink/Source for Current Output Q Over, Under, Out-of-Range Position Monitoring Q Remote Control of Positioning Devices Q Simplify Control of Potentiometer Outputs Applications Options–add to end of model number DF Fast response time, consult factory U Conformal coating for moisture resistance Accessory—order as separate line item API BP4 Spare 4-terminal plug, black All models are field rangeable Models can be pre-set to your specifications. Order APD 4008 D for operation on low voltage power. Model Input Output Power APD 4008 Field configurable—specify range if factory is to set switches Field configurable—specify range if factory is to set switches 85-265 VAC, 50/60 Hz or 60-300 VDC APD 4008 D 9-30 VDC or 10-32 VAC Description The APD 4008 accepts a resistance input from potentiometer, slidewire, linear position, displacement, or rotational devices and provides an optically isolated DC voltage or current output that is linearly related to the potentiometer position. The APD 4008 will accept any potentiometer with a value of 0-100 Ω through 0-1 MΩ without recalibration and without affecting accuracy. The APD 4008 output can be field-con- figured via external rotary and slide switches. Offsets and/or input ranges other than 0 to 100% of the potentiometer range can also be selected. The full 3-way (input, output, power) isolation makes this mod- ule useful for ground loop elimination, common mode signal rejection or noise pickup reduction. Sink/Source Output The APD 4008 has a 20 VDC loop excitation supply for the output. This power supply can be used to power a passive mA device. If not required, the APD 4008 output can be wired as a passive output. Sinking/sourcing versatility allows the APD 4008 to produce a powered or unpowered mA output allowing it to work with powered or unpowered mA devices. LoopTracker API exclusive features include two LoopTracker LEDs (green for input, red for output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and/or troubleshooting. Output Test An API exclusive feature includes the test button to provide a fixed output (independent of the input) when held depressed. The test output level is potentiometer adjustable from 0 to 100% of output span. The output test button greatly aids in saving time during initial startup and/or troubleshooting. How to Order Please specify Model Input range (if factory is to pre-set) Output range (if factory is to pre-set) Options as required Potentiometer Input Field selectable ranges via switch settings See table for complete listing 3 wire connection required Minimum: 0-100 Ω Maximum: 0-1 MΩ Input span: 10-100% of potentiometer range Input offset: 0-90% in 10% increments Input Impedance 10 MΩ minimum Common Mode Rejection 120 dB minimum LoopTracker Variable brightness LEDs indicate I/O level and status DC Output Ranges Field selectable ranges via switch settings See table for complete listing Voltage: 0-1 VDC to 0-10 VDC, 10 mA max Bipolar voltage: ±5 VDC or ±10 VDC Current: 0-2 mADC to 0-20 mADC 20 V compliance, 1000 Ω at 20 mA Output Logic Normal Output Calibration Multi-turn zero and span potentiometers ±15% of span adjustment range typical Output Loop Power Supply 20 VDC nominal, regulated, 25 mADC, <10 mVRMS max. ripple May be selectively wired for sinking or sourcing mA output Output Test Front button sets output to test level when pressed Potentiometer adjustable 0-100% of span Output Ripple and Noise Less than 10 mVRMS Linearity Better than ±0.1% of span Ambient Temperature Range and Stability –10°C to +60°C operating ambient Better than ±0.02% of span per °C stability Response Time Standard: 70 milliseconds nominal DF option: 1 millisecond nominal. Output noise levels will be greater than standard specifications. Consult factory. Isolation 1200 VRMS minimum Full isolation: power to input, power to output, input to output Housing and Connectors IP 40, requires installation in panel or enclosure For use in Pollution Degree 2 Environment Mount vertically to a 35 mm DIN rail Four 4-terminal removable connectors, 14 AWG max wire size Power 85-265 VAC, 50/60 Hz or 60-300 VDC, 2 W maximum D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 2 W maximum Removable Plugs Dimensions 0.89" W x 4.62" H x 4.81" D 22.5 mm W x 117 mm H x 122 mm D Height includes connectors Universal Power Output LoopTracker LED Input LoopTracker LED Output Test Function Front Zero and Span Connect mA Output for Sink or Source Use Any Potentiometer © 11-19 api-usa.com 1220 American Way Libertyville, IL 60048 Phone: 800-942-0315 Fax: 800-949-7502 ABSOLUTE BSOLUTE P PROCESS ROCESS I INSTRUMENTS NSTRUMENTS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 See Wiring Diagrams on Next Page Quick Link: api-usa.com/4008 Minute Setup! 1 Free Factory I/O Setup! H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H Made in USA File E145968 85-265 VAC, 60-300 VDC model only Applications Link api-usa.com/apps Pb Lead Free
Absolute Process Instruments APD 4008: Measuring Instruments, Transmitter Category Related Instructions
Garmin Dash Cam ™ 10/20 Owner’s Manual January 2014 190-01711-00_0B Printed in Taiwan Product reference manual for the Garmin Dash Cam 10 Dash Cameras. This guide elaborates on device features and device features, hardware instructions, safety features.
: Introduction: * Simply press the "S" button, iPDA® NT-076 AutoScan FM Transmitter will scan the clearest frequency for you, then tune the radio and enjoy your music! Features: * AutoScan function automatically finds the clearest frequency. * RDS (Radio Da Official product manual for the iPDA NT-076 AutoScan Transmitter. This reference includes diagnostic information, control functions, usage procedures, installation support.
Continental Automotive France SAS Interior Division- Body & Security -1- July 05, 2018 User manual of the Continental Radio Frequency Transmitter Model: TXN5 TXN6 TXN7 Complete device guide for the Continental Refrigerator TXN5 Transmitter. This guide explains the features and product handling, regulatory notices, usage recommendations, calibration steps.
Product reference manual for the Vaisala HUMICAP HMW92 Temperature Controller. This guide provides information on shutdown procedures, safety guidelines, assembly reference, wiring setup.