Absolute Process Instruments DuoPak APD 2003 Manuals
1 pdf manual(s) Absolute Process Instruments DuoPak APD 2003 for free download (Document Types: Manual )
Absolute Process Instruments DuoPak APD 2003 Manual [PDF] (2 pages)
- Identifier: id-1913151
- Brand: Absolute Process Instruments
- Device: DuoPak APD 2003 Media Converter
- Type: PDF
- Key Aspects: Periodic Inspection Checklists, Component Longevity Optimization, Hardware Verification Checklists
- UPD Date: 15.04.2026
- Source File: 1809609.pdf
- Pages: 2
- Description: Stepwise user guide for the Absolute Process Instruments DuoPak APD 2003.
Click to expand and read text
api-usa.com 1220 American Way Libertyville, IL 60048 Phone: 800-942-0315 Fax: 800-949-7502 BSOLUTE ROCESS NSTRUMENTS, Inc. © 06-14 O Two Independent Channels with Full Isolation O Zero and Span for Each Output O Input and Output LoopTracker ® LEDs O Output Test/Manual Override for Each Channel O Built-In I/O Power Supplies Q Monitor a DC Signal and Position Q Convert/Isolate Dual Output Transmitters Applications Channel 1 DC Input Range Factory configured, please specify input type and range Voltage: 0-10 mVDC to 0-100 VDC Bipolar voltage: ±50 mVDC to ±10 VDC Current: 0-1 mADC to 0-50 mADC, 4-20 mADC Voltage input impedance: 200 kΩ minimum Current input impedance: 50 Ω typical Input com. mode rejection: 120 dB minimum Current input voltage burden: 1.25 VDC max. at 20 mA Input loop power supply: 15 VDC, ±10%, regulated, 25 mADC, may be connected for sinking or sourcing mA input Channel 2 Potentiometer Input Range Use any 3 wire full-travel potentiometer 1 VDC excitation provided to potentiometer Consult factory for other ranges and configurations Minimum range: 0-100 Ω Maximum range: 0-1 MΩ Input impedance: 100Ω to 1 MΩ minimum Input com. mode rejection: 100 dB minimum LoopTracker Variable brightness LEDs indicate I/O levels for each channel Channel 1 and Channel 2 Output Ranges Factory configured, please specify for each output channel Voltage: 0-1 VDC to 0-10 VDC, 10 mA max up to 20 VDC with M19, M29, M39 Bipolar voltage: ±1 VDC to ±10 VDC Current: 0-1 mADC to 0-25 mADC, 4-20 mADC 20 V compliance, 1000 Ω at 20 mA Output Calibration Multi-turn zero and span potentiometers for each output channel ±15% of span adjustment range typical Characteristics Accuracy: ±0.1% of span (incl. adj. resolution and linearity) Output ripple and noise: Less than 10 mVRMS Isolation: Full 5-way, 1200 VRMS minimum Response Time 70 milliseconds typical Ambient Temperature Range and Stability –10°C to +60°C operating ambient, <±0.04% span/°C stability Output Loop Power Supplies 20 VDC nominal, regulated, 25 mADC for each output channel May be selectively wired for sinking or sourcing mA output Output Test Front buttons set each output to test level when pressed Each test level potentiometer adjustable 0-100% of span Housing and Connectors IP 40, requires installation in panel or enclosure Mounts to standard 35 mm DIN rail Eight 4-terminal removable connectors, 14 AWG max wire size Power 85-265 VAC, 50/60 Hz or 60-300 VDC, 6 W maximum D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 6 W maximum Removable Plugs Quick Link api-usa.com/2000 Dimensions 1.78" W x 4.62" H x 4.81" D 45 mm W x 117 mm H x 122 mm D Height includes connectors Sink or Source mA Output for Each Channel Output LoopTracker LED for Each Channel Adjustable Output Test Function for Each Channel Zero and Span for Each Channel Custom I/O Ranges Description The APD 2003 DuoPak accepts one DC voltage or current input and one potentiometer input and provides two optically isolated DC voltage or current outputs that are linearly related to the inputs. The input ranges and the output ranges for each channel are independent and can be specified as required. This provides an economical two channel solution in one device. Typical applications include signal conversion, isolation, and redundancy (i.e. to prevent failure of the entire loop if one device fails), or a combination of these. Each input signal is filtered, amplified, and then passed through an opto-coupler to the output stages. Full 5-way isolation (input 1, input 2, output 1, output 2, power) make this module useful for ground loop elimination, common mode signal rejection, and noise pickup reduction. I/O Sink/Source Versatility Standard on the APD 2003 is a 15 VDC loop excitation supply for the DC input channel and 20 VDC loop excitation sup- plies for each output channel. These power supplies can be selectively wired for sinking or sourcing allowing use with any combination of powered or unpowered milliamp I/O devices. LoopTracker API exclusive features include four LoopTracker LEDs (green for each input, red for each output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and troubleshooting. Output Test An API exclusive feature includes output test buttons for each channel to provide a fixed output (independent of the input) when held depressed. Terminals are also provided to operate the test functions remotely for each channel. This also allows use as a remote manual override to provide a temporary fixed output if desired. The test output level for each channel is potentiometer adjust- able from 0 to 100% of the output span. The output test greatly aids in saving time during initial startup and/or troubleshooting. Universal Power Input LoopTracker LED for Each Channel Free Factory I/O Setup! ® Two Channel Signal Converter/Isolator/Transmitter APD 2003 Channel 1: DC to DC Channel 2: Potentiometer to DC Connect Sink or Source mA for DC Input Options—add to end of model number R1 Channel 1 I/O reversal (i.e. 20-4 mA out) R2 Channel 2 I/O reversal (i.e. 20-4 mA out) R3 Channel 1 and channel 2 I/O reversal M19 Channel 1 high voltage output >10 V up to 20 V M29 Channel 2 high voltage output >10 V up to 20 V M39 Channel 1 and channel 2 high voltage output U Conformal coating for moisture resistance Accessory—order as separate line item API BP4 Spare removable 4 terminal plug, black How to Order Models are factory ranged. See I/O ranges above left. Ranges and options for each channel must be specified on order Channel 1 input range Channel 2 input range Channel 1 output range Channel 2 output range Model Description Power APD 2003 DuoPak 2 channel DC-DC, Pot.-DC converter/isolator/ transmitter 85-265 VAC, 50/60 Hz or 60-300 VDC APD 2003 D 9-30 VDC or 10-32 VAC Options and Accessories H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H Made in USA
DuoPak APD 2003: Media Converter Category Related Instructions
© 2018 SignalCore, Inc. All Rights Reserved Hardware Manual SC5317A* & SC5318A 6 GHz to 26.5 GHz RF Downconverter www.signalcore.com *SC5317A Coming Soon Step-by-step user manual for the SIGNALCORE SC5317A Media Converter. It provides technical information on system configuration, detailing setup, safety features, maintenance.
Installation & Operation Guide Version 1.0 Published: July 28, 2015 HB-T-HDMI and HB-R-HDMI HDMI to HDBaseT Mini Converter Comprehensive instruction manual for the AJA HB-T-HDMI Media Converter. The manual provides step-by-step instructions on safety protocols, performance guidelines, testing procedures.
2 2 5 5 f / I - f / f c o n v e r t e r N o . 2 2 5 5 V 1 0 2 - U K F r o m s e r . n o . 9 8 0 4 3 1 0 0 1 Maintenance and service manual for the PR electronics 2255 Media Converter. It describes usage and user preferences, testing procedures, connectivity setup, cleaning instructions.
MARS T1000 User Manual Version 1.3.0 Advanced user guide for the Hollyland MARS T1000 Intercom System. This guide includes safety, product maintenance, control functions.