ACTi TCM-7811 Manuals

3 pdf manual(s) ACTi TCM-7811 for free download (Document Types: Installation instructions, Hardware user manual, Operation & user’s manual)

Document Preview & Text Transcription

www.acti.com ACTi Knowledge Base Category: Installation & Configuration Note Sub-category: Integration, Hardware Model: All 4-inch and 5-inch outdoor domes Firmware: N/A Software: N/A Author: Ando.Meritee Published: 2011/09/07 Reviewed: 2011/09/07 1 Waterproof Installation of Dome Cameras Contents Introduction Installation of Conduit Installation in Humid Environment Introduction ACTi outdoor dome cameras are all waterproof, rated as IP66. However, this waterproof condition is guaranteed only if both camera and the cables are properly sealed off. It is necessary to use waterproof flex conduit to protect the Ethernet cable that connects the camera from its outdoor installation spot to the indoors or to the nearest waterproof junction box. The flex conduit can be mounted to the camera by using conduit gland (US: conduit fitting). The conduit gland is not included to the package of the dome camera and has to be purchased separately from local providers. While purchasing conduit gland, the installer only needs to know the camera-side dimension. It is 3/4” (trade size), or with actual physical diameter of 26.441mm. All the following ACTi models have the same hole dimension: ACM-7411, ACM-7511, TCM-7011, TCM-7411, TCM-7811, KCM-7111, KCM-7211. As for the size of the other end of the conduit gland (hosting the flex conduit), it is up to the user to decide. Different sizes are available in the market. It is recommended to use the size that can host at least 1/2” (trade size) tubing so that the Ethernet cable together with RJ-45 head can go through it smoothly. The following chapter explains how to mount the flex conduit to the camera by using conduit gland. www.acti.com 2 Installation of Conduit Have the Ethernet cable inserted through the flex conduit together with RJ-45 connector. You may also consider to do the RJ-45 connector crimping after pushing the cable through the conduit. Disassemble the conduit gland. Slide the clamping nut around flex conduit some 10-20 cm away from the top. Fit the sealing insert (made of rubber) to the top of the flex conduit. On the camera side, decide which of the 2 possible holes you are going to use to connect the flex conduit. There is one hole on the side, and one on the bottom. Whichever you pick, remember to seal off the other one with the metal patch (included in the camera set). www.acti.com 3 Scenario 1 – using the side hole. Scenario 2 – using the bottom hole. Screw the body of the conduit gland into the camera and fix it with the lock nut (included in the set of conduit gland that you purchased) from the inside of the camera.. Connect the Ethernet cable to the camera’s network port. If you are not using PoE, then please remember to pull the DC power cable through the flex conduit as well, and connect to the camera at this point. www.acti.com 4 Push the head of the flex conduit, wrapped with sealing insert, into the body of the conduit gland. Screw the clamping nut tightly onto the body of the conduit gland. Adjust the viewing angle and focus of the camera and put the dome cover back on, and tighten it by using the screws. You have completed a fully waterproof installation!

Document Preview & Text Transcription

TCM-7811 H.264 Megapixel IP IR D/N CCD Vandal Proof Outdoor PoE Fixed Dome (DC 12V / PoE) Ver. 2012/6/25 VoIPon www.voipon.co.uk [email protected] Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299 www.acti.com TCM-7811 Hardware User’s Manual 2 Table of Contents 0. Precautions 3 1. Introduction 4 Package Contents ........................................................................... 4 Features and Benefits ..................................................................... 5 Safety Instructions .......................................................................... 7 Physical description ........................................................................ 9 2. Installation Procedure 15 Connect the IP Outdoor Rugged Dome ........................................ 15 1) Remove the cover ............................................................... 15 2) Select cable entrance ......................................................... 15 3) Connect cables to connectors ............................................ 15 Mount the IP Outdoor Fixed Dome (Surface) ............................... 16 Mount the IP Outdoor Fixed Dome (Flush) .................................. 18 Mount the IP Indoor Fixed Dome (Wall) ...................................... 19 How to Do the Waterproof Installation ....................................... 20 Product Specification .................................................................... 23 3. Accessing Camera 24 If you have DHCP server / router .................................................. 24 If you do NOT have DHCP server / router ..................................... 24 VoIPon www.voipon.co.uk [email protected] Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299 www.acti.com TCM-7811 Hardware User’s Manual 3 0. Precautions Read these instructions You should read all the safety and operating instructions before using this product. Heed all warnings You must adhere to all the warnings on the product and in the instruction manual. Failure to follow the safety instruction given may directly endanger people, cause damage to the system or to other equipment. Servicing Do not attempt to service this video device yourself as opening or removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel. Trademarks All names used in this manual are probably registered trademarks of respective companies. Liability Every reasonable care has been taken during the writing of this manual. Please inform your local office if you find any inaccuracies or omissions. We cannot be held responsible for any typographical or technical errors and reserve the right to make changes to the product and manuals without prior notice. FCC/CE Regulation NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the users will be required to correct the interference at their own expense. VoIPon www.voipon.co.uk [email protected] Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299