Operating manual [PDF] (12 pages)
- Updated: 19.07.2026
Document Preview & Text Transcription
Operating Manual
Electronic Column Scale, class III approved, M20011
ADE GmbH & Co.
Hammer Steindamm 27 – 29
22089 Hamburg / GERMANY
+49(40)432776-0
Fax
+49(40)432776-10
E-mail:
[email protected]
1
050100-Rev000-M20011
Contents
Contents .................................................................................................................................................. 1
Components and Features...................................................................................................................... 2
Display symbols ..................................................................................................................... 2
Installation and use of scale .................................................................................................................... 3
Check carton contents ........................................................................................................... 3
Power Supply of the scale...................................................................................................... 3
Positioning of the scale .......................................................................................................... 3
Use of the scale where approved scales are imperative ....................................................... 3
Connecting additional equipment........................................................................................... 3
Quality check.......................................................................................................................... 4
EC type approval.................................................................................................................... 4
Use of the scale....................................................................................................................................... 4
Weighing ................................................................................................................................ 4
Body Mass Index (BMI).......................................................................................................... 5
Evaluation of the Body Mass Index........................................................................................ 5
Tare functions ........................................................................................................................ 5
Set zero.................................................................................................................................. 5
Hold function .......................................................................................................................... 5
Unit function ........................................................................................................................... 5
Cleaning, Maintenance and Re-approval................................................................................................ 6
Cleaning ................................................................................................................................. 6
Service ................................................................................................................................... 6
Safety instructions.................................................................................................................. 6
Storage and Transport ........................................................................................................... 6
Warranty................................................................................................................................. 6
Re-approval............................................................................................................................ 7
Technical data ......................................................................................................................................... 7
Certificate of conformity........................................................................................................................... 8
050100-Rev000-M20011
2
Components and Features
Keys
Function
ON ................................ To start the scale
OFF............................... To shut the scale off
ZERO............................ To set the scale to zero
PRESET TARE............. To manually set a value to be tared
HOLD............................ To fix the weighing result
BMI ............................... To evaluate the BMI (Body-Mass-Index)
SEMI AUTO TARE ....... To tare a value automatically
UNITS........................... To change the weighing unit (kg, lb)
CLEAR.......................... Clear indication
ENTER.......................... Confirm indication
0 – 9.............................. Numeric keys for storing tare value or height for evaluation of BMI
Display symbols
Arrows indicating which weighing mode or evaluation mode you have chosen
Pages Preview: