ADEMCO 5890 Manuals
1 pdf manual(s) ADEMCO 5890 for free download (Document Types: Installation instructions)
ADEMCO 5890 Installation instructions [PDF] (4 pages)
- Identifier: id-1117855
- Brand: ADEMCO
- Device: ADEMCO 5890 Kitchen Appliances
- Type: Installation instructions, PDF
- Key Aspects: Step-by-Step Assembly Procedures, Routine Functionality Testing, Regulatory Compliance and Standards
- UPD Date: 29.07.2026
- Source File: 1040541.pdf
- Pages: 4
- Description: Complete instruction guide for the ADEMCO 5890.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 N5987V2 5/98 ® No. 5890 PASSIVE INFRARED MOTION DETECTOR/TRANSMITTER INSTALLATION INSTRUCTIONS For use with QED control panels ONLY! GENERAL INFORMATION The 5890 Passive Infrared Motion Detector/Transmitter is a battery-operated wireless device intended for use as part of a QED 5800 series wireless alarm system. Designed for use in commercial and residential installations, the 5890 is a wall-mounted unit with a standard lens that provides wide-angle protection up to a range of 40 feet (12m). For best coverage, mount the detector so that the likely direction of intruder motion is across the pattern. Two optional interchangeable lenses are available for this detector – the 199PA Pet Alley lens, and the 199LR Long Range lens (see PROTECTION PATTERNS FOR OPTIONAL LENSES on last page). This document provides installation instructions for the 5890, but the installer must be familiar with the Installation Instructions for the QED 5800 Wireless Alarm System with which the 5890 is intended to be used. FEATURES • Wireless operation for fast installation. • Dual element pyro-electric sensor provides positive protection while minimizing false alarms. • Alternate polarity pulse count option offers greater stability in adverse environments. • Provision to turn LED on while walk testing (LED is turned off after testing). • Tampered cover – unit transmits message if cover is removed. • Wall or corner mounting options. • Optional Pet Alley and Long Range lenses available. SYSTEM DESCRIPTION Optical System: Uses efficiently designed Fresnel lenses. Radio Transmitter: The built-in transmitter serves only as the communication link to the alarm system's Receiver/Control, and can send alarm, tamper, supervisory, and battery status messages to the system's QED receiver/control. The transmitter is not used for detection purposes. Each detector has a unique ID code permanently assigned at the factory. This ID needs to be "enrolled" by the QED control system at the time of installation. This allows each detector used in the system to be uniquely identified. The QED control must be programmed to "enroll" the 5890 as an "RF" type unit (i.e., supervised RF). To conserve battery life during normal operation, no more than one transmission sequence will occur within a 3-minute period. There is no such time restriction in "test" mode. Alternate Polarity Pulse Count: Two jumper- selectable detection response modes are provided: Instant response (Pulse Count OFF) and Alternate Polarity Pulse Count (Pulse Count ON). With Pulse Count OFF, any detected change in infrared energy will trigger an immediate alarm signal. This mode is recommended when the detector is used to monitor a narrow hallway where coverage is provided by only a single zone. Use the Pulse Count ON mode when the detector is installed in areas where periodic changes in infrared energy levels are normal (for example, where forced air heating ducts are present). In this mode, it requires at least two detected changes in infrared energy within a short period before an alarm will be triggered. Important Note: If the detector is to be used in the Pulse Count mode, be sure to walk test the unit in this mode. SPECIFICATIONS Coverage: Standard Lens : 40 ft x 56 ft (12 m x 17 m). 18 zones (9 long, 5 inter- mediate, 4 short range). 199LR Lens : 60 ft x 6 ft (18m x 1.8m). 5 zones (1 long, 2 inter mediate, 2 short range). 199PA Lens : 40 ft x 60 ft (12m x 18m) 12 zones. Pulse Count: Installer-selectable On/Off link. Detectable Walk Rate: 0.5 – 5ft/sec (0.15 – 1.5m/sec). Mtg. Height: 7ft nominal (2.1m), but may be mounted at other heights (see Table 1). Walk Test Indicator: Red LED with Test/Normal (disable) link. Batteries: Two 3-volt Lithium batteries. Use only Ademco No. 466, Duracell DL123A, Panasonic CR123A, Sanyo CR123A, or Varta CR123A. 0perating Temperature: 32°F – 122°F (0°C – 50°C) Operating Humidity: Up to 95% RH (max.), non- condensing. Dimensions: 2-11/16"W x 5"H x 1-7/8"D (68mm x 127mm x 48mm). Figure 1. Standard Wide Angle Protection Pattern BATTERY INSTALLATION 1. Remove front cover by inserting a large screwdriver blade (or small coin) in groove between cover and base at the location shown in Figure 2; rotate blade to override snap fit, then lift cover off. 2. Observing correct polarity, install the two Lithium batteries (supplied) into the battery holders, as shown in Figure. 5. Make sure the batteries are firmly seated. 3. Replace the cover (snap fit). Battery Caution: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 100°C, or incinerate. Dispose of used batteries promptly. Keep away from children. Programming Note: If the detector’s ID has not been programmed into the system (i.e., this is an initial detector installation), refer to the PROGRAMMING section below and perform the ID “enrolling” procedure before mounting or testing the detector. PROGRAMMING The QED control system must “enroll” the detector’s ID during installation of the system. The QED control should be programmed to enroll the 5890 as an “RF” type unit (i.e., supervised RF). To program the detector, place the LED jumper in the TEST position (see Fig. 5), the Pulse Count jumper in the OFF position, batteries installed, and cover on. Temporarily cover the lens (a cloth will do) to prevent any activation by the detector. When prompted for the device’s serial number, you may either manually enter it or transmit from the unit (remove the cloth cover and motion your hand over the lens to activate the detector, press the tamper switch, etc.). Refer to the QED control panel installation instructions for programming details. Return LED jumper to the NORMAL position after it is enrolled in the control. INSTALLATION HINTS ¥ Do not install where the detector is exposed to direct sunlight or directly above strong sources of heat. • Make sure the detection area does not have obstructions (curtains, screens, large pieces of furniture, plants, etc.) which may block the pattern of coverage. • Avoid locating a unit in areas which contain objects likely to produce a rapid change in temperature, such as central heating, radiators or ducts (or heaters of any kind), air conditioners, open flame, etc. • Do not mount on an unstable surface. INSTALLATION Radio Transmission Path Check Verify that a strong transmission path between the 5890 and the system's Receiver/Control exists before permanently mounting the detector. Do this by performing the Walk Test (described later) with the detector temporarily mounted in its proposed location. The 5890 will transmit when sensing motion (waving arm or walking into area). Sometimes, moving the detector only a few inches means the difference between a strong and weak transmission path. Experiment until you are satisfied that the location provides the strongest transmission path, while still being practical for the protection pattern desired. This test also verifies that the detector has been correctly programmed into the system. Normal Mounting Mount the unit to a firm vertical surface (flat on wall or in corner). 1. Remove front cover. 2. Temporarily loosen (do not remove) the screw holding the PC board in the detector base (see Fig. 5 for location of this screw).
Similar Manuals in the Kitchen Appliances Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Delimano DS22-6 |
Delimano Kitchen Appliances Operation & user’s manual (File: PDF, 25-06-2026) |
84 | 1407 | 268 | 25-06-2026 | view all manuals | |
Gifas-electric 1970W |
#G3C386: 1970W Kitchen Appliances Operation & user’s manual |
8 | 816 | 204 | 28-04-2026 | view all manuals | |
Omron E3C-LDA-N Series |
Omron E3C-LDA-N Series Manual (Manual ), @586A5X |
20 | 987 | 198 | 03-04-2026 | view all manuals | |
LeeBoy 8515D |
8515D (Kitchen Appliances ePDF Guide, #8QC9TN) |
398 | 1097 | 231 | 16-06-2026 | view all manuals | |
Wolf WGSC100S |
Wolf WGSC100S User Guide (Use & care manual), @1G7HQW |
84 | 1210 | 242 | 28-04-2026 | view all manuals | |
Proxim Tsunami Multipoint |
Tsunami Multipoint (Kitchen Appliances ePDF User Manual, #15R6DM) |
19 | 653 | 131 | 29-07-2026 | view all manuals |