Advantech-DLoG DLT-U1100 Manuals
1 pdf manual(s) Advantech-DLoG DLT-U1100 for free download (Document Types: Quick start)
Advantech-DLoG DLT-U1100 Quick start [PDF] (2 pages)
- Identifier: id-1893706
- Brand: Advantech-DLoG
- Device: DLT-U1100 UPS
- Type: PDF
- Key Aspects: FAQ Section for Common Queries, Glossary of Technical Terms, Routine Functionality Testing
- UPD Date: 24.04.2026
- Source File: 1829056.pdf
- Pages: 2
- Description: User and installation guide for the Advantech-DLoG DLT-U1100.
Click to expand and read text
1 Mounting by electronic and mechanical skilled persons Quickstart DLT-U1100 2 Important notes Personal injury Explosion hazard The following icons are used in this quick start guide to indicate dangers: NOTICE Risk of physical damage 3 Technical data Battery Lithium-ion battery Bridging time 10 min Maximum output 40 W Nominal output voltage of the UPS 12 VDC Nominal input voltage of the UPS 12, 24, 48 VDC Input voltage range 9 to 60 VDC Output voltage range 10 to 14 VDC Charging time 2,5 h (fully recharge a completely discharged battery) Connector input Lumberg 0315 04-Pin male Connector output Lumberg 0305 04-Pin female Qualifications required for mounting of the UPS DLT-U1100 This Quickstart Poster will show you how to perform the mechanical and electrical mounting of the Uninterruptible Power Supply (UPS) DLT-U1100. It is intended for skilled persons. WARNING: Electric shock due to contact with live parts / property damage •� Only electronic and mechanical skilled persons are permitted to install the DLT-U1100. Specialized knowledge of batteries and the applicable safety regulations is also required. •� Unauthorized persons must be kept away from the UPS which contains rechargeable Lithium Ion batteries. •� If�the�DLT-U1100�is�incorrectly�installed�and�configured,�the�DLoG�GmbH�warranty for this device will be canceled. •� DLoG�GmbH�assumes�no�liability�for�damages�caused�directly�or�indirectly� by the incorrect installation or usage of the DLT-U1100. •� DLT-U1100 operators must be trained. Current manuals on the internet The current DLT-U1100 manuals can always be found in our Download Center on the internet www.advantech-dlog.com (Download menu). Intended use The�DLT-U1100�is�a�battery-operated�uninterruptible�power�supply�for�the�Advantech-DLoG� industrial PCs MTC 6 and XMT 5, each with 12/24 VDC power supply unit. If the DLT-U1100 is connected, MTC 6 and XMT 5 cannot be started or shut down automati- cally via vehicle ignition. NOTICE: No combination of UPS + automatic start/shut down via ignition possible MTC 6 and XMT 5 can be used with automatic startup/shut down capabilities. This automatic feature controls the startup and shutdown of the industrial PC via thebutton or the vehicle’s ignition. If the DLT-U1100 is connected, MTC 6 and XMT 5 cannot be started or shut down via vehicle ignition Hence�it�is�important�to�make�the�following�setting�before the DLT-U1100 is connected to MTC 6 and XMT 5: •� Define�that�the�MTC�6�and�XMT�5�always�start�and�shut�down�with�the� button, not via ignition signal. •� Make�the�respective�adjustments�in�the�configuration�tools: ���“DLoG�Config“�for�MTC�6,�“DLoG�NextConfig“�for�XMT�5 Otherwise, MTC 6 and XMT 5 can not be started, because with a connected UPS system no ignition signal is available. WARNING: Vehicle “EMERGENCY Stop Switch” cannot switch off industrial PCs with UPS If an MTC 6 or XMT 5 industrial PC with an uninterruptible power supply (UPS) is installed on a vehicle, the vehicle emergency stop switch will not affect the the industrial PC. WARNING: Explosion hazard •� Do�not�use�the�DLT-U1100�at�locations�where�flammable�gases�or�vapors�are present. •� Do not use the DLT-U1100 near gas stations, fuel depots, chemical facilities or locations where blasting work is being performed. •� Do�not�throw�the�DLT-U1100�into�fire;�the�batteries�may�explode. WARNING: Electrical shock possible from touching live parts / property damage •� Do not commission the DLT-U1100 if there are visible signs of damage to the device. •� The DLT-U1100 contains Lithium Ion batteries. Replacement of the rechargeable batteries by the customer is expressly prohibited. •� Do not open or modify the DLT-U1100. •� Do not perform any repairs. Repairs on the DLT-U1100 may be made only by ���Service�Centers�authorized�by�Advantech-DLoG. •� Do not submerge the DLT-U1100 and cables in water or other liquids because of the danger of electrical shock. •� Use�only�original�power�cables�by�Advantech-DLoG;�they�meet�special� ���requirements�for�low-temperature�flexibility,�UV�resistance,�oil�resistance,�etc. •� Condensation can occur if the DLT-U1100 is moved from a cold environment into a work room. Therefore, allow for an acclimatization time of approx. 2 hours. Temperature range, in which the UPS supplies the industrial PC with power from the battery -10 to +50 °C (+14 to +122 °F) Temperature range, in which the batteries of the UPS are recharged 0 to +45 °C (+32 to +113 °F) Storage temperature range -20 to +60 °C (-4 to +140 °F) Vibration/shock Class 5M3 according to DIN EN 60721-3-5 IP protection IP65 Weight 1.1 kg Warranty DLT-U1100 device (batteries excluded) As�specified�in�Advantech-DLoG�TOB Warranty batteries Six (6) months from delivery Any other or additional use is not as intended. The user/operator of the DLT-U1100 is solely respon- sible for any resulting damage. This also applies to unauthorized�modifications�to�the�unit.
DLT-U1100: Related Instructions
Quick Start Guide DLoG MPC 6 1 Confi gure the device on the desktop Prerequisites Power supply cable DLoG pre-converter, to connect the DLoG MPC 6 to an AC pow User reference guide for the Advantech-DLoG MPC 6 Industrial PC. The guide covers usage and operational safety, specifications, warranty information, power requirements.
www.advantech-dlog.com Advantech-DLoG ∕∕ DLT-V83 Series DLT-V83 Series Industrial PCs Manual V1.31 Manual Quick start guide for the Advantech-DLoG DLT-V8310 Industrial PC. This documentation highlights features and backup procedures, component replacement, specifications.
Mounting instructions: Attaching the keyboard holder to the DLT-V72 / DLT-V83 by DLoG GmbH 2015-2016 Mounting instructions: Attaching the keyboard holder to Owner’s guide for the Advantech-DLoG DLT-V72 Series Touch terminals. This guide explains the features and functional overview, installation guides, technical specifications.
DLT-V83 Series Industrial Computer Operating Instructions V2.00 (EN) Operating Instructions Quick reference guide for the Advantech-DLoG DLT-V83 Series Industrial PC. The guide describes usage and specifications, technical overview, service procedures, backup procedures.
DLT-V72 Industrial Computer Operating Instructions V2.50 (EN) Preliminary Device setup manual for the Advantech-DLoG DLT-V72 Series Industrial PC. It explains operation, maintenance, and startup procedures, power requirements, warranty information.
www.advantech-dlog.com Advantech-DLoG ∕∕ DLT-V72 Series DLT-V72 Series Industrial PC Manual V2.00 Manual User guidebook for the Advantech-DLoG DLT-V72 Series Industrial PC. This guide provides information on hardware setup, performance guidelines, setup validation, configuration options.
Similar Manuals in the UPS Category
NetBackup 5330 Appliance Product Description Guide Release 2.6.1 Device operation guide for the Symantec NetBackup 5330 Server. The manual elaborates on features and setup, setup validation, device features, safety features.
T1000 SERIES UPSMON PRO USER GUIDE 120V 1-3kVA Document: 96449 -001 March 2020 User guidebook for the Toshiba UPSMON PRO T1000 Series UPS. It explains operation, maintenance, and device overview, device calibration, setup tips.
PDU8000 Modular Precision PDC V2.0 User Manual Issue 04 Date 2021-04-13 HUAWEI TECHNOLOGIES CO., LTD. Installation and maintenance guide for the Huawei PDU8000 Series Power distribution unit. This guide elaborates on device features and maintenance schedule, component overview, installation steps.
1/2 Instruction Leaflet Montageanweisung Notice d°installation Instrucciones de montaje Istruzioni per il montaggio 安 安装说明 装说明 Инструкц Technical setup manual for the Eaton DDC-250/2 UPS. This manual explains system parameters, technical guidelines, detailing setup, error handling.