  • The NEM Long Distance Lamp Memory System is

    1

  • - 45 -

    2

Document Preview & Text Transcription

NEM-LD DESCRIPTION: The NEM Long Distance Lamp Memory System is designed for communication with remote locations up to 4000’ away, or to each elevator in a building. Sub stations are available in surface or flush mount styles, and require a separate circuit board to be added for the call-in function. Three wires are required to each sub station. Master stations are available with or without a handset. Aiphone Communication Systems • 1700 130th Ave. N.E. • Bellevue, WA 98005 (425) 455-0510 • FAX: (425) 455-0071 • (800) 692-0200 • www.aiphone.com - 44 - NEM Lamp Memory System for Long Distance/Elevators SPECIFICATIONS: Power Source: DC 24V. Use PS-2410A for 10, 20-call masters. PS-24E for 30, 40-call masters. Current Consumption: Maximum 45W Power Output: 500mW Calling: Press call button on sub to ring master and light LED, remaining until answered. Communication: Press-to-talk, release-to-listen at master, or voice actuated handset (NEM-nA-LD) Hands free at remote Talk Channel: Single talk channel Wiring: 2 common wires plus 1 individual wire per sub station looped, or 3 wires homerun from each sub station. Shielded cable is recommended. Use Aiphone #822203 (22AWG) or #821803 (18 AWG) or use 82-series multi-conductor wire. Wiring Distance: 2000’ w/ 22AWG, 4000’ w/18AWG Mounting: Desk or wall mount Dimensions (HxWxD): IF-DA-NLD: 5” x 4” x 1” IE-JA-NLD: 4-1/2” x 4-9/16” x 1/2” NEM-10/20-LD: 5-1/2” x 13-5/8” x 10-1/4” NEM-30/40-LD: 5-1/2” x 19-1/2” x 10-1/4” NEM-10A/20A-LD: 6-15/16” x 17-9/16” x 10-1/4” NEM-30/40A-LD: 6-15/16” x 23-7/16” x 10-1/4” FEATURES: • Two-way communication between master and subs • Clear communication to subs in elevators • Sub stations can be up to 4000’ away • Call-in from sub remains lit on master until answered • Master is “push-to-talk”, “release-to-listen” • Hands free communication at sub stations • Sub stations are weather resistant • Available in 10, 20, 30 & 40 call sizes • SINGLE MASTER SYSTEM ONLY NEM-20A-LD SOME APPLICATIONS: • Office Complexes • Large Commercial Facilities • Gated Entries • Parking Lots • Airports
Aiphone NEM-10 Specifications Main Page Preview

Aiphone NEM-10 Specifications [PDF] (2 pages)

  • Brand: Aiphone
  • Model: NEM-10
  • Format: PDF
  • Updated: 02.07.2026
  • The NEM series is a selective calling open voice

    1

  • The intercom system shall be of an open voice,

    2

Document Preview & Text Transcription

DESCRIPTION: The NEM series is a selective calling open voice style intercom system. Masters are available in 10, 20, 30, and 40 station sizes, with optional 20 and 40 call add-on selectors. Maximum capacity is 120 stations. Master stations can be wall or desk mounted. Sub stations are available in surface or flush mount styles, with or without privacy. Outdoor stations are available in surface or flush mount styles. Vandal and weather resistant sub stations are also available. Incoming calls from a sub station are annunciated with an electronic tone and an LED, remaining activated until the call is answered at the master or reset at the calling location. The master answers the call by selecting the button with the lit LED. Communication at the master is press-to-talk, release-to-listen. Person at the sub station speaks hands free. The master station can selectively call and talk with any sub station in the system. The privacy feature on selected sub stations prevents eavesdropping from the master station. Several Special Order Product variations of this system are available. Additional features available through SOP are selective door release, CCTV camera call-up, two levels of call signaling from sub stations, and master units modified for long distance/ elevator applications. See Aiphone’s SOP catalog for more information on these systems. FEATURES: • Console master system with Lamp Memory, where call-in tone and LED remains active until answered • 10, 20, 30 and 40 call master stations • Expandable to 120 stations with the addition of 20 and 40 call add-on selectors • Wide assortment of accessories to meet a variety of applications • Push-to-talk at master, hands free at sub station • Selective calling, Group calling, or All Call • Separate transmit, recieve, All Call, and call tone volume controls • Two master stations can be included in a system with NEW-5’s (1 per 5 sub stations) OFF Button Talk button All Call button Voice/Call tone Volume controls Station Select buttons Power On/Off Switch Speaker Mic SPECIFICATIONS NEM Master Stations NEM-10, NEM-20, NEM-30, NEM-40 NEM-20 Pictured NAMES & FUNCTIONS:
Aiphone NEM-10 Instructions Main Page Preview

Aiphone NEM-10 Instructions [PDF] (2 pages)

  • Brand: Aiphone
  • Model: NEM-10
  • Format: PDF
  • Updated: 17.04.2026
  • - INSTRUCTIONS -

    1

Document Preview & Text Transcription

- INSTRUCTIONS - The NEM-EM system provides communication from a central master station to multiple sub stations (up to 80). A call from a standard room station is annunciated with a steady LED light and an intermittent tone. An emergency call from a bathroom pull cord (NBR-7AS) is annunciated with a flashing LED light and buzzer tone. A standard call can be reset at the master station. An emergency call must be reset at the bathroom pull cord location. WIRING DIAGRAM: NEM-20EM Red Blu Blk NBR-7AS NB-L NA-NE NEM-EM NEM Lamp Memory Emergency Call System NEM-nEM Master Station NBR-7AS Pull Cord and NBY-4AEM Corridor Lamp Individual Components for NEM-EM System: NA-A: Surface mount sub station NA-AN: Surface mount sub with privacy NA-NE: Flush mount sub, aluminum (backbox included) NB-L: Flush mount ceiling speaker sub station NBY-4A/EM: Corridor lamp for NEM-EM system PC-359B: Call holding circuit board (required if standard sub stations are not used) PS-24E: 24V DC Power Supply (for NEM-10EM, NEM-10AEM only) PS-45E: 13.8V DC, 8A Power Supply (for 20, 30, 40-station masters) NEM-EM TERMINAL DEFINITIONS: + Positive (24V DC for NEM-10EM; 13.8V DC for NEM-20~40EM) - Negative 1~40 Station number E Common communication M Common for Emergency Call Signal PS-45E Blu Blu NA-A NA-AN NBY-4A/EM Red Grn Blk NBR-7AS Special Order Products IMPORTANT NOTES: 1. When wiring NA-A or NA-AN to NBR-7AS, install diode (1N4001~4007) as shown above. 2. If no corridor lamp is included with NA-A/AN, leave jumper between D and E attached. 3. If corridor lamp is installed with NA-NE or NB-L, separate Green and Black wires, and connect Blue and Black wires together. A D E Red Org/ Wh Grn Blk + - 1 2 3 ~ 20 E M S S Pg. 1 D1: Value 1N4001~4007 D1 Remove jumper Jumper blue and black wires when corridor lamp is used. Jumper green and black wires when corridor lamp is not used.