Air King 4YN46C/9318C Manuals

1 pdf manual(s) Air King 4YN46C/9318C for free download (Document Types: Operating instructions & parts manual)

Air King 4YN46C/9318C Operating instructions & parts manual [PDF] (2 pages)

  • Identifier: id-110352
  • Brand: Air King
  • Device: 4YN46C/9318C Fan
  • Type: PDF
  • Key Aspects: Product Performance Metrics, Unpacking and Inspection Guidelines, Critical Operational Precautions
  • UPD Date: 02.05.2026
  • Source File: 15704.pdf
  • Pages: 2
  • Description: Operational manual for the Air King 4YN46C/9318C.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Rev. F 4/01 4 2084576 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. DESCRIPTION The AirKing 18" (45.7 cm) Multi Mount Fan features Pull Cord operation and a 3-paddle Fan Blade. This Fan has a permanently lubricated motor with a 9 ft (2.74 m) 18/3 cord set and are constructed of sturdy, powder coated steel. SPECIFICATIONS Motor ....................................... 120V, 50/60 Hz (18", 45.7 cm) Blade diameter ....................... 18" (45.7 cm) Model 4YN46C/9318C Speeds .................................... 3 Control .................................... Pull Cord Air flow distribution ................. 360° Approvals ................................ UL Listed. Close mesh Fan guard meets OSHA requirements. HIGH VELOCITY MULTI MOUNT FAN 18" (45.7 cm) MODEL 4YN46C/9318C OPERATING INSTRUCTIONS & PARTS MANUAL GENERAL SAFETY INFORMATION 1. Make certain that the power source conforms to the electrical require- ments of the Fan. 2. The power cord is equipped with a three-prong grounded plug that must be inserted into a matching receptacle. Under no circumstances must the grounding prong be cut off the plug. Where a two-prong wall receptacle is encountered, it must be replaced with a properly grounded three-prong receptacle installed in accordance with the National Electrical Code (NEC) and all applicable local codes and ordinances. This work must be done only by a qualified electrician, using copper wire only. WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS ARE NOT PERMITTED IN CANADA. MODELO 4YN46C/9318C Rev. F 4/01 1 2084576 3. Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed and of the proper gage and length. Never use a single extension cord to operate more than one Fan. 4. Do not insert fingers or foreign objects into the Fan. Do not block or tamper with the Fan in any manner while it is in operation. Do not touch the Fan while in operation or just after it has been turned off, as some parts may be hot enough to cause injury. 5. Unplug power cord before installing or servicing the Fan. WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD. 6. This Fan is intended for general use ONLY. It must NOT be used in potentially dangerous locations such as flammable, explosive, chemi- cal-laden or wet atmospheres. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE. 7. Be sure Fan is on a stable surface when operating, to avoid chance of it overturning. 8. DO NOT use Fan in a window. Rain may create an electrical hazard. 9. Completely reassemble Fan, according to instructions before recon- necting to power supply. WALL/CEILING INSTALLATION 1. WOOD STRUCTURES: Locate the wall or ceiling stud nearest to the desired Fan location. Attach the Fan to the stud using a 3/8" diameter x 2" long Lag Screw (Not Supplied). (Figure 1) NOTE: ALWAYS INSTALL THE YOKE TO A MINIMUM OF 2 X 4 STUDDING. 2. STEEL STRUCTURES: Attach the Fan using a 3/8" bolt of the appropriate length, with a Flat Washer, Lock Washer and a 3/8" Nut (Not Supplied). 3. MASONARY STRUCTURES: Attach Fan using a 3/8" Lag Screw, with a Lag Shield of appropriate length (Not Supplied). (Figure 1) NOTE: IN ALL CASES, IT IS RECOMMENDED THAT A FLAT WASHER BE PLACED ON BOTH SIDES OF THE FAN YOKE TO ASSIST IN SMOOTH ROTATION. 4. Attach Pull Cord String and Pendant to Switch. Figure 1 Lag Screw Wall or Ceiling Stud Flat Washers Lag Shield (Masonary Only) REF NO. NO. DE PARTE DESCRIPCIÓN CANT. OPERACIÓN 1. Enchufe el cable de conexión eléctrica dentro de un tomacorriente de tres hojas conectado ampropiadamente a tierra. 2. Utilizando el cordón accionador, seleccione la velocidad deseada del Ventilador. 3. ADVERTENCIA: Este ventilador debe ser usa do solmente en unambiente limpio y seco. Si producto esta montado de alguna otra manera espec´ifica que indica la hoja de instrucción, purdiera anularse y no tener valor la garantia del fabricante. MANTENIMIENTO ADVERTENCIA: DESCONECTE SIEMPRE EL CORDÓN ANTES DE INTENTAR REALIZAR CUALQUIER FUNCIÓN DE SERVICIO. LIMPIEZA: Use un trapo y una solución de jabón suave, tal como detergente líquido para lavar trastes. ADVERTENCIA: No use gasolina, bencina, diluyente de pintura ni limpiadores fuertes en aerosol, ya que éstos dañarán el ventilador. ALMACENAMIENTO: Cuando no lo utilice, mantenga el aparato en un lugar limpio y seco. EL MOTOR HA SIDO PERMANENTEMENTE LUBRICADO. ATENCIÓN: EL CABLE DE APOYO SECUNDARIO SUMINISTRADO DEBE UTILIZARSE CUANDO QUIERA QUE EL VENTILADOR SEA MONTADO POR LO ALTO, PARA MAYOR SEGURIDAD. CABLE DE APOYO SECUNDARIO 1. Entrelazar el cabo del Cable alrededor de los Alambres de Diámetro Grande tanto por la Parte Delantera como por la Parte Trasera de la Defensa del Ventilador. (Figura 2) 2. Fijar la Mordaza del Cable de manera que la "U" del lado del cabo del bucle quede con cabo de 1 a 2 pulgadas aproximadamente. Apretar las Tuercas de la Mordaza. Hay que asegurarse de que ninguna parte del Cable estorbe a la Paleta. (Figura 2) 3. Enroscar el otra cabo del Cable alrededor de una viga o armazón segura de la edificación, o de otro soporte cercano al Ventilador. (Figura 3) Recoger todo lo del cable que quede sobrando. CUIDADO: UTILIZAR SÓLO LOS ELEMENTOS METÁLICOS DE MONTAJE QUE SE RECOMIENDAN PARA ESTE VENTILADOR. 4. Fijar la Mordaza de Cable restante como se indica en la parte 2. Hay que recortar el exceso de cabo de manera que sólo queden de 1 a 2 pulgadas después de la Mordaza 5. Revisar el Ensamblado para cerciorarse de que la Paleta esté libre de toda obstrucción. ATENCIÓN: EL USO DEL CABLE DE APOYO SECUNDARIO NO GARANTIZA LA PROTECCIÓN DE PERSONAS CONTRA LESIONES Y EL MONTAJE DEL VENTILADOR Y DEL CABLE PODRÍAN DAÑARSE SI SE MALTRATAN, SE DESCUIDAN O NO SE INSTALAN BIEN. Alambres Grandes de la Defensa Figura 3 Figura 2 Cable de Apoyo Secundario ** Suministros por Bolso de Piezas Componentes Físicas (2098012) MODEL 4YN46C/9318C SPEED HIGH MED LOW CFM 5350 4180 3010 M3/s 2.52 1.97 1.42 RPM 1600 1275 950 Amps 1.65 1.27 .95 Watts 194 148 110 dB A 67 58 49 24 23 21 9 10 22 14 13 12 1 20 16 7 8 5 4 3 6 2 11 10 8 9 19 17 18 15 15 22 17 1 2065510 Placa de Identificación 1 2 2050015 Cordón Eléctrico 1 3 2010636 Cubierta del Motor 1 4 2055001 Interruptor del Cordón Accionador 1 5 ** Cordón Accionador con Colgante 1 6 2090552 Tuerca para el Alambre 2 7 5096056B Rejilla Trasera 1 8 5060015 Placa de Pivote 2 9 2091162 Tornillo de #8 x 1/2 PPH Tipo F 4 10 2091126B Tornillo de #6 x 5/8" PTH 3 11 2030021SB Motor 1 12 5081050B Hélice 1 13 5090044 Tornillo Prisionero de 1/4-28 x 3/8 1 14 5060027 Horqueta 1 15 5090041 Remache 2 16 2011601 Espaciador de Caucho 2 17 2091143 Tornillo de #8 x 3/8" PPH Type F 4 18 5096052BK Rejilla Delantera 1 19 2090547 Contratuerca 3 20 2010237L Adorno de Protección 1 21 2070027 Ojo de Buey 1 22 5090045 #10-32 x 1/2 MWM SERR F-ZP 23 ** Grapa de Cable 2 24 ** Cable de Seguridad 1