READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. GENERAL SAFETY INFORMATION When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following: 1. Read all instructions before installing or using exhaust fan. 2. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. 3. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 4. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-related construction. 5. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities. CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS. Models: AK917, AK927 www.airkinglimited.com 210575917 Rev. A 1-06 Bulb Heat Lamp with Fan SAVE THESE INSTRUCTIONS 6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 7. Ducted fans must always be vented to the outdoors. 8. This unit must be grounded. 9. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE. WARNING: DO NOT INSTALL OVER A TUB OR MOUNT IN A SHOWER STALL ENCLOSURE. 10. Do not install into a ceiling thermally insulated to a value greater than R-40. 11. NEVER place a switch where it can be reached from a tub or shower. WARNING: DO NOT USE IN KITCHENS. WARNING: THIS UNIT IS DESIGNED AND TESTED TO BE A SUPPLEMENTAL HEATER FOR USE WITH A TIMER OR A SWITCH. IT IS NOT INTENDED TO BE USED AS THE PRIMARY SOURCE OF HEAT AND CONTROLLED BY A THERMOSTAT. IMPORTANT INSTRUCTIONS - OPERATING MANUAL 1 of 8 SECTION 3 Existing Construction 1. Set housing in position between the joist and trace an outline onto the ceiling material (Figure 4). Set housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities. Install the rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the rails to the joists with screws or nails (not provided) to ensure proper installation (Figure 3). SECTION 4 Ducting CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. 1. Remove any tape that might be holding the damper in place during shipping and connect the ducting to the fan’s duct collar (Figure 5). Secure in place using tape or screw clamp. Always duct the fan to the outside through a wall or roof cap. SECTION 5 Wiring CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. 1. Wiring Fan/Heat Bulb(s) Independently: Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and two hot (black and blue). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle. 1a. From where you have access to inside the fan’s junction box, connect the white wire from the house to the white wire from the fan. Connect one hot (black) wire from the house to the black wire from the fan (this is the fan control). Connect the second hot (blue) INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Unit 1. Unpack fan from the carton and confirm that all pieces are present. In addition to the unit you should have: 1 - Grill 4 - Mounting Rails 1 - Instruction/Safety Sheet 2. Remove the wire compartment cover by loosening the two screws holding the cover in place (Figure 1). WARNING: DO NOT INSTALL OVER A TUB OR MOUNT IN A SHOWER STALL ENCLOSURE. 3. Choose the location for your unit. To ensure the best air and sound performance, it is recommended that the length of ducting and the number of elbows be kept to a minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise and airflow restrictions. This fan will require at least 6" of clearance in the ceiling, and will mount through drywall up to 3/4" thick. The fan mounts between 16" on center joists using the provided mounting rails. 4. Select the most convenient electrical knockout and remove using a straight- blade screw driver (Figure 2). SECTION 2 New Construction 1. Install the rails on the housing and position the housing next to the joist. Line up housing so it will be flush with the finished ceiling. Secure the ends of the rails with screws or nails (not included) to the joists and slide housing into final position (Figure 3). www.airkinglimited.com 210575917 Rev. A 1-06 2 of 8 Figure 4 Figure 5 Figure 1 Screws Wire Compartment Cover Figure 2 Figure 3 Joist Housing Mounting Rails 2. Remove grill from carton and attach springs from grill to posts on either side of housing (Figure 9). 5. Install a 250 watt maximum, R-40 Type A heat lamp (not included) into the socket and center the grill around the lamp. NOTE: Model AK927 uses 2 - 250 watt maximum R-40, Type A heat lamps. 6. Restore power and test your installation. SECTION 7 Use and Care CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT. CAUTION: ALLOW LAMP(S) TO COOL BEFORE CLEANING THE UNIT OR REPLACING THE LAMPS. 1. Cleaning the Grill: Remove heat lamp(s) and detach grill springs from posts to release grill from housing. Use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to instructions in Section 6 Completing the Installation, to reinstall grill. 2. Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER. CAUTION: ALLOW LAMP(S) TO COOL BEFORE REPLACING. 3. Changing the Heat Lamps: Disconnect power to the unit. Unscrew heat lamp(s) from lamp holder and replace with 250 watt maximum, R-40, type A heat lamp. www.airkinglimited.com 210575917 Rev. A 1-06 3 of 8 Figure 9 wire from the house to the blue wire from the fan (this is the heat bulb control). Connect the ground wire from the house to the green wire from the fan (Figure 6). Use approved methods for all connections. NOTE: On model AK927 connect the Hot (Blue) wire from the house to the two Blue wires from the unit. 2. Wiring Fan/Heat Bulb together: Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and one hot (black). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle. 2a. From where you have access to inside the fan’s junction box, connect the one white wire from the house to the white wire from the fan. Connect the black wire from the house to both the black and blue wires from the fan. Connect the ground wire from the house to the green wire from the fan (Figure 7). Use approved methods for all connections. NOTE: On model AK927 connect the hot (black) wire from the house to the black and two blue wires from the unit. 3. Reinstall the wire compartment cover using the two screws removed in Step 2 of SECTION 1 Preparing the Unit. Make sure all wires are tucked inside of the compartment and are not being pinched or showing through. SECTION 6 Completing the Installation 1. Insert plug from fan into the receptacle located under the light socket (Figure 8). Figure 6 Ground Supply from house White Hot (Black) From Fan Hot (Blue) Figure 7 Ground Supply from house White Hot (Black) From Fan Hot (Blue) Figure 8 Posts Springs Grill
Air King AK917 Specifications Main Page Preview

Specifications [PDF] (1 pages)

  • Updated: 07.07.2026

Document Preview & Text Transcription

SPECIFICATIONS EXHAUST FANS AK917 70 CFM/3.5 SONES @ 0.10" wg. HVI CERTIFIED 120 Volts, 2.6 amps, 60 hz. • Grill White, polymeric grill (flame retardant ABS UL rated 94-5V) secured in place with torsion springs; easily removed if neccessary, dimensions - 10" x 10". • Blower Wheel One piece polymeric wheel, 3 7/8" diameter, 21/2" wide with 21 fins. • Motor Heavy duty, plug in 2 pole motor. Life time lubrication, thermally protected. Rated 120 volts, 60 hz., 0.90 amps. • Fan Housing 23 gauge galvanized steel housing. Dimensions 81/4" x 8" x 5 7/8". • Duct Collar Plastic collar for 4" duct connection, comes complete with built in non-metallic back draft damper for quiet operation. • Ventilating Area For bathrooms up to 70 sq. ft. • Lamping Information 1 - 250 watt maximum, type R40 bulb, medium base, 850 Btu. CUL/HVI - TYPE IC RATED Canada: 110 Glidden Road Brampton, Ontario L6T 2J3 Tel: (905) 456-2033 Fax: (905) 456-1015 U.S.: 820 Lincoln Drive West Chester, Pennsylvania 19380-4466 Tel: (877)-304-3785 Fax: (610) 696-8048 Updated 1-06 Specifications subject to change without notice. • Unit Mounting The housing will mount in ceilings with at least 6" of clearance and through drywall thickness up to 3/4", with a rough-in opening of 81/4" x 8". Rated for ceilings insulated to R-40. The housing will mount between 16" on center joists, using the 4 supplied housing mounting rails. • Single Pack Shipping Info Box Dim: 141/4" x 111/2" x 73/4" UPC: 0-8316227001-6 Shipping Weight: 7 lbs. C US PROJECT LOCATION CONTRACTOR ARCHITECT ENGINEER SUBMITTED BY DATE FAN MODEL CFM IN RPM WATTS AMPS SONES QTY OPTIONAL EQUIPMENT NUMBER NUMBER W.G. & REMARKS PERFORMANCE HVI Sones Fan Speed Power Static Pressure (inches of w.g.) @ .1 SP RPM Watts 0 0.05 0.1 0.125 0.15 0.2 0.25 0.3 Air Flow - CFM Air-King exhaust fans are tested by the Air Movement and Control Association (AMCA) in accordance with HVI test standard 916, (Air Flow Test Standard) and HVI test standard 915 (Procedure For Loudness Rating Of Residential Fan Products). The Performance results are certified and verified by the Home Ventilating Institute (HVI).
Air King AK917 Operating manual Main Page Preview

Operating manual [PDF] (8 pages)

  • Updated: 10.07.2026

Document Preview & Text Transcription

IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. GENERAL SAFETY INFORMATION When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following: SAVE THESE INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer.If you have questions, contact the manufacturer. b) Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE FOLLOWING: a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-related construction. b) Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities. c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS. d) Ducted fans must always be vented to the outdoors. e) This unit must be grounded. f) To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. g) Read all instructions before installing or using exhaust fan. WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE. WARNING: DO NOT INSTALL OVER A TUB OR MOUNT IN A SHOWER STALL ENCLOSURE. a) Do not install into a ceiling thermally insulated to a value greater than R-40. b) NEVER place a switch where it can be reached from a tub or shower. WARNING: DO NOT USE IN KITCHENS. WARNING: THIS UNIT IS DESIGNED AND TESTED TO BE A SUPPLEMENTAL HEATER FOR USE WITH A TIMER OR A SWITCH. IT IS NOT INTENDED TO BE USED AS THE PRIMARY SOURCE OF HEAT AND CONTROLLED BY A THERMOSTAT. www.airkinglimited.com 210575917 Rev. C 1-11 1 of 8 Bulb Heat Lamp with Fan Models: AK917, AK927 INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan 1. Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have: 1 - Grill 1 - Damper Assembly (attached) 4 - Mounting Rails 1 - Instruction/Safety Sheet 2. Remove the wire compartment cover by loosening the two screws holding the cover in place (Figure 1). 3. Choose the location for your fan. To ensure the best air and sound performance, it is recommended that the length of ducting and the number of elbows be kept to a minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise and airflow restrictions. This fan will require at least 8" of clearance in the ceiling or wall, and will mount through drywall up to 3/4" thick. The fan mounts between 16” on center joists using the provided mounting rails. 3. Select the most convenient electrical knockout and remove using a straight-blade screw driver (Figure 2). SECTION 2 New Construction 1. Install the rails on the housing and position the housing next to the joist. Line up housing so that it will be flush with the finished ceiling. Secure the ends of the rails with screws or nails (not included) to the joists and slide the housing into the final position (Figure 3). SECTION 3 Existing Construction 1. Set housing in position between the joist and trace an outline onto the ceiling material (Figure 4). Set housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities. Install the rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the rails to the joists (Figure 3). www.airkinglimited.com 210575917 Rev. C 1-11 2 of 8 SECTION 4 Ducting CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. 1. Remove any tape that might be holding the damper in place during shipping and connect the ducting to the fan’s duct collar (Figure 5). Secure in place using tape or screw clamp. Always duct the fan to the outside through a wall or roof cap. SECTION 5 Wiring CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. NOTE: This unit includes a side access panel for wiring that does not require the removal of the fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the blower assembly and internal wiring compartment. Both methods are equally effective. 1a. Wiring Fan/Heat Bulb(s) Independently: Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and two hot (black and blue). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle. 1b. From where you have access to inside the fan’s junction box, connect the white wire from the house to the white wire from the fan. Connect one hot (black) wire from the house to the black wire from the fan (this is the fan control). Connect the second hot (blue) wire from the house to the blue wire from the fan (this is the heat bulb control). Connect the ground wire from the house to the green wire from the fan (Figure 6). Use approved methods for all connections. NOTE: On model AK927 connect the Hot (Blue) wire from the house to the two Blue wires from the unit. Housing Joist Mounting Rails Figure 3 Figure 2 Figure 1 Screws Wire Compartment Cover Figure 4 Figure 5 Figure 6 Hot (Black) Hot (Blue) White Ground From Fan Supply from house 2. Wiring Fan/Heat Bulb together: Run wiring from an approved wall switch carrying the appropriate rating. One neutral (white), one ground (green or bare copper), and one hot (black). Secure the electrical wires to the housing with an approved electrical connector. Make sure you leave enough wiring in the box to make the connection to the fan’s receptacle. 2a. From where you have access to inside the fan’s junction box, connect the one white wire from the house to the white wire from the fan. Connect the black wire from the house to both the black and blue wires from the fan. Connect the ground wire from the house to the green wire from the fan (Figure 7). Use approved methods for all connections. NOTE: On model AK927 connect the hot (black) wire from the house to the black and two blue wires from the unit. 3. Reinstall the wire compartment cover using the two screws removed in Step 2 of SECTION 1 Preparing the Unit. Make sure all wires are tucked inside of the compartment and are not being pinched or showing through. SECTION 6 Completing the Installation 1. Insert plug from fan into the receptacle located under the light socket (Figure 8). 2. Remove grill from carton and attach springs from grill to posts on either side of housing (Figure 9). www.airkinglimited.com 210575917 Rev. C 1-11 3 of 8 3. Install a 250 watt maximum, R-40 Type A heat lamp (not included) into the socket and center the grill around the lamp. NOTE: Model AK927 uses 2 - 250 watt maximum R-40, Type A heat lamps. 4. Restore power and test your installation. SECTION 7 Use and Care CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: ALLOW LAMP(S) TO COOL BEFORE CLEANING THE UNIT OR REPLACING THE LAMPS. NOTE: On installations where the ventilation fan and heat lamps are controlled independently: After extended use of the heat lamps without the ventilation fan operating, temperature sensing devices inside the unit may engage the ventilation fan for a time to maintain conditions inside of the unit enclosure. Once conditions inside of the unit enclosure are similar to room ambient conditions, the fan will disengage. This fan cycling will repeat as needed. 1. Cleaning the Grill: Remove heat lamp(s) and detach grill springs from posts to release grill from housing. Use a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry grill before reinstalling. Refer to instructions in Section 6 Completing the Installation, to reinstall grill. 2. Cleaning the Fan Assembly: Wipe all parts with a dry cloth or gently vacuum the fan. NEVER IMMERSE ELECTRICAL PARTS IN WATER. CAUTION: ALLOW LAMP(S) TO COOL BEFORE CLEANING THE UNIT OR REPLACING THE LAMPS. 3. Changing the Heat Lamps: Disconnect power to the unit. Unscrew heat lamp(s) from lamp holder and replace with 250 watt maximum, R-40, type A heat lamp. Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Fan does not operate when the switch is on. 1a. A fuse may be blown or a circuit tripped. 1a. Replace fuse or reset circuit breaker. 1b. Connector plug from motor is not plugged in. 1b. Turn off power to unit. Remove Grill and plug motor into receptacle in housing. Restore power to unit. 1c. Wiring is not connected properly. 1c. Turn off power to unit. Check that all wires are connected. 1d. Motor has stopped operating. 1d. Replace motor. 2. Fan is operating, but air moves slower than normal. 2. Obstruction in the exhaust ducting. 2. Check for any obstructions in the ducting. The most common are bird nests in the roof cap or wall cap where the fan exhausts to the outside. 3. Fan is operating louder than normal. 3a. Motor is loose. 3a. Turn off power to unit. Remove grill and check that all screws are fully tightened. Restore power to unit. 3b. Fan blade is hitting housing of unit. 3b. Call your dealer for service. Figure 7 Hot (Black) Hot (Blue) White Ground From Fan Supply from house Figure 8 Figure 9 Grille Ressort Montant

Document Preview & Text Transcription

Exhaust Fans Deluxe Quiet Fans Deluxe Quiet Fans w/Light Quiet Fans Quiet Fans w/Light Deluxe Round Fans w/Light Decorative Round Fans w/Light Decorative Oak Fans w/Light Fans with Light High Performance Fans Advantage Fans Through the Wall Fan Deluxe Heaters Advantage Heaters Bulb Heaters The Advantage 3" and 4" Duct Series Exhaust Fans provide economical ventilation for bathrooms, utility rooms and other areas needing ventilation. • Large keyhole slots on models AS50, AS60, and AS70. Models AS90 and AS120 include adjustable hanging brackets for mounting to joist on 16" centers. • AS50, AS60, and AS70 feature a slim 33/4" housing, allowing installation into either ceiling or wall applications. • UL listed for installation over a tub or shower on a GFCI circuit. United States: 820 Lincoln Avenue • West Chester, PA 19380 • 877-304-3785 Canada: 110 Glidden Road • Brampton, ON L6T-2J3 • 800-250-8767 The Deluxe Combination Heater Series will instantly make your home a more comfortable place to live. • 1500 watts providing 5120 BTUs of heat. • Includes adjustable hanging brackets for mounting to joist on 16" centers or large keyhole slots. • Wall control switches included with the unit. • Units with light feature a moonstone glass lens with 100 watt maximum light and 7 watt night light (Bulbs not included). • Energy Efficient Fluorescent model AKF965. • 4" Exhaust duct connection. The Advantage Combination Heater Series provides an economical solution to adding supplemental warmth. • Includes the features of the Deluxe Heater Series, except the night light and control switches • Energy Efficient Fluorescent model AKF55. The Bulb Heater Series provides instant supplemental heat where it is needed the most. • Uses one or two 250 watt maximum R-40 infrared bulbs (Not included). • Includes adjustable hanging brackets for mounting to joist on 16" centers or large keyhole slots. • 4" Exhaust duct connection What is a Sone? - The sone is an internationally recognized unit of loudness, which simplifies reporting of sound output. The sones translate laboratory decibel readings into numbers that correspond to the way people sense loudness. Double the sone is double the loudness. In everyday terms, one sone is equivalent to the sound of a quiet refrigerator in a quiet kitchen. CFM - Cubit Feet per Minute. A measurement of how much air flows during a one minute period. www.airkinglimited.com Rev. D 10/06 Advantage Exhaust Fans Model CFM Sones Duct Size AS50 50 3.0 3" AS60 60 3.5 3" AS70 70 5.0 3" AS90 90 2.5 4" AS120 120 4.0 4" Models AS50, AS60, AS70 Models AS90, AS120 Deluxe Heaters Model Features CFM Sones AK965L Heat/Vent/Light/Night Light 70 3.5 AKF965 Heat/Vent/Light/Night Light 70 3.5 AK960 Heat/Light/Night Light N/A N/A AK905 Heat/Vent 70 3.5 AK093L Heat/Vent/Light/Night Light 70 3.5 The Through the Wall Exhaust Fan Series adds versatility to your ventilation needs. • Vent directly to the outside. • All metal housing installs into walls from 4" to 9" thick. • Spring loaded aluminum backdraft damper. • 8" round diameter housing for maximum air flow. Through the Wall Exhaust Fan Model CFM Sones Duct Size EWF-180 180 3.0 8" Advantage Heaters Bulb Heaters Model Features CFM Sones AK55L Heat/Vent/Light 70 3.5 AKF55 Heat/Vent/Light 70 3.5 Model Features CFM Sones AK912 Single Bulb Heat N/A N/A AK917 Single Bulb Heat/Fan 70 3.5 AK922 Double Bulb Heat N/A N/A AK927 Double Bulb Heat/Fan 70 3.5 Models AK922, AK927 Models AK912, AK917 C US The Decorative Oak Exhaust Fan Series with Light brings a stylized touch of wood to your ventilation needs. • Stylish solid Oak grill • High impact polycarbonate lens with bright 100 watt maximum light (Bulb not included). • Includes adjustable hanging brackets for mounting to joist on 16" centers. Model DRLC707 can also be installed using the large keyhole slots. • UL listed for installation over a tub or shower on a GFCI circuit. The Decorative Round Exhaust Fan/Light Series provide quiet ventilation with decorative grills to compliment the decor. • Includes adjustable hanging brackets for mounting to joist on 16" centers or large keyhole slots. • Moonstone Glass Lens with two 60 watt maximum lights for up to 120 watts of lighting (Bulbs not included). • Available in Bronze, Nickel, White, or Brass finishes. • UL listed for installation over a tub or shower on a GFCI circuit. The Quiet Round Exhaust Fan/Light Series provide quiet ventilation with decorative grills to compliment the decor. • Includes adjustable hanging brackets for mounting to joist on 16" centers or large keyhole slots. • Moonstone Glass Lens with two 60 watt maximum lights for up to 120 watts of lighting (Bulbs not included). • Available in Bronze, Nickel, or White finishes. • UL listed for installation over a tub or shower on a GFCI circuit. The combination Bath Fans with Light provide an economical way to light and ventilate without compromising style. • Includes adjustable hanging brackets for mounting to joist on 16" centers or large keyhole slots. • High impact polycarbonate lens with bright 100 watt maximum light (Bulb not included). • Energy Efficient Fluorescent models ASF50, ASF70, ASF90, ASF120 • UL listed for installation over a tub or shower on a GFCI circuit. High performance, attractive stylized grill and quick installation makes this fan right for the job. • Quick mount Snap-In bracket. • Includes wire nuts and romex connector • Durable flame retardant ABS plastic housing ensures quiet operation and maximum performance. • UL listed for installation over a tub or shower on a GFCI circuit. High Performance Exhaust Fans Deluxe Quiet Exhaust Fans The Deluxe Quiet Exhaust Fan Series provides powerful ventilation, low sound levels and attractive grills. • Models AK80LS, AK110LS, AK150LS, and AK200LS are ENERGY STAR® Labeled. • Electronically balanced centrifugal blower wheel. • Includes adjustable hanging brackets for mounting to joist on 16" centers. • UL listed for installation over a tub or shower on a GFCI circuit. Model CFM Sones Duct Size AK80LS 80 0.6 4" metal AK110LS 110 1.5 4" metal AK150LS 150 1.5 6" metal AK200LS 210 2.0 6" metal AK300LS 310 3.5 6" metal The Deluxe Quiet Exhaust Fan Series with light provides powerful ventilation, low sound levels and attractive grills. • ENERGY STAR® Labeled. • 26 watt maximum, energy efficient compact fluorescent 4 pin quad tube lamp, (lamp included) • Electronically balanced centrifugal blower wheel. • Includes adjustable hanging brackets for mounting to joist on 16" centers. • Moonstone Glass Lens for maximum light diffusion • UL listed for installation over a tub or shower on a GFCI circuit. Deluxe Quiet Exhaust Fans w/Light Quiet Exhaust Fans The Quiet Exhaust Fan Series provides powerful ventilation, low sound levels and attractive grills. • Models AK80LS-1, AK80, AK90, and AK110 are ENERGY STAR® Labeled. • Electronically balanced centrifugal blower wheel. • Includes adjustable hanging brackets for mounting to joist on 16" centers. • UL listed for installation over a tub or shower on a GFCI circuit. Model CFM Sones Duct Size AK80LS-1 80 1.0 4" AK80 80 1.5 4" AK90 90 1.5 4" AK110PN 100 1.5 4" AK110 110 2.0 4" AK130 130 2.5 4" Model Night Light CFM Sones Duct Size AKF80LS 4 watt 80 0.8 4" metal AKF100LS 4 watt 100 1.5 4" metal Quiet Round Exhaust Fans w/Light The Deluxe Round Series Exhaust Fans with light provide powerful ventilation with attractive round grill styling. • Includes adjustable hanging brackets for mounting to joist on 16" centers or large keyhole slots. • Moonstone Glass Lens with bright 100 watt maximum light and 7 watt night light (Bulbs not included). • Energy Efficient Fluorescent model AK863FL. • UL listed for installation over a tub or shower on a GFCI circuit. Deluxe Round Exhaust Fans w/Light Model Night Light CFM Sones Duct Size AK863L 7 watt 100 3.5 4" AK863FL 7 watt 100 3.5 4" AK864L - 100 3.5 4" Decorative Round Exhaust Fans w/Light Exhaust Fans with Light Model CFM Sones Duct Size ASLC50 50 3.0 4" ASF50 50 3.0 4" ASLC70 70 4.0 4" ASF70 70 4.0 4" ASLC90 90 2.5 4" ASF90 90 2.5 4" ASLC120 120 4.0 4" ASF120 120 4.0 4" Model CFM Sones Duct Size BFQ50 50 1.0 4" BFQ75 70 2.0 4" BFQ90 90 2.5 4" BFQ110 100 3.5 4" BFQ140 120 4.0 4" Decorative Oak Exhaust Fans w/Light Model Night Light CFM Sones Duct Size DRLC107 7 watt 100 3.5 4" DRLC707 - 70 4.0 4" Model DRLC107 Model DRLC707 Model Finish CFM Sones Duct Size AKLC701 Bronze 70 2.5 4" AKLC702 Nickel 70 2.5 4" AKLC703 White 70 2.5 4" Model Finish CFM Sones Duct Size DRLC701 Bronze 70 4.0 4" DRLC702 Nickel 70 4.0 4" DRLC703 White 70 4.0 4" DRLC709 Brass 70 4.0 4"