Aktobis WDH-DS3 Manuals

1 pdf manual(s) Aktobis WDH-DS3 for free download (Document Types: Operating manual)

Aktobis WDH-DS3 Operating manual Main Page Preview

Operating manual [PDF] (10 pages)

  • Updated: 24.08.2026

Document Preview & Text Transcription

Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: [email protected] Adsorption Dehumidifier WDH-DS3 Dear Customer, You have chosen a high-quality product. To ensure that you get a lot of enjoyment from this product, here are a few more tips: In case of any problems: We hope that the unit meets your expectations! If, despite the greatest possible care, there should ever be cause for complaint, please contact us briefly, as we are very concerned about your satisfaction and would like to clear up any misunderstanding. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: [email protected] The first farm: As the internal piping comes into contact with moisture for the first time, it can take up to approx. 3 hours for the first liquid to accumulate in the collection container, depending on the room humidity. In addition, a slight plastic smell may be perceived during the first hours of operation. This is normal and not a cause for concern. Room humidity and dehumidification performance: If you want to check the room humidity and the associated dehumidification performance with your own humidity meter (hygrometer), please avoid attaching this humidity meter to a wall, as this will falsify the true humidity content of the room air. See also the explanations under Troubleshooting !!! Important safety instructions: - Supervise the dehumidifier when children are near the appliance ! - Watch out for electricity, never walk into or insert objects into the appliance ! - Do not place any objects on the dehumidifier ! - Place the dehumidifier on a stable and even surface. - Do not block the exhaust air (lamella) of the unit and please ensure sufficient space/clearance at and around the fan ! - Please do not use this appliance in a large laundry or laundry room. - Ensure that there is sufficient air supply to the unit, otherwise it can lead to a reduction in performance and, in the worst case, to overheating and/or fire ! - Only qualified personnel or electricians are allowed to open the unit ! - Make sure that no moisture gets to the electrics of the unit ! - Only use the recommended voltage for operating the unit ! - Make sure that the power cable is unfolded (untied) before connecting it to the socket! - Make sure that the plug is cleanly and properly connected to the socket before using the appliance ! - Never reach near the plug or socket with wet hands ! - The condensate is not suitable for drinking ! - Please do not use multiple sockets for operating the dehumidifier ! - Do not repair defective or damaged cables on the unit yourself, you could get a severe electric shock ! - This appliance is not intended to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. - Make sure that highly flammable substances (e.g. gases/oils etc.) are never in the vicinity of the unit ! - If you are not going to use the unit for a long time, switch it off and disconnect the mains plug ! Please switch off the unit immediately and disconnect it from the mains/power supply if anything seems to be wrong !!! In this case, please contact a specialist and do not attempt to repair the unit yourself !!! Examples: Fan does not run during operation or the fuse has blown. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: [email protected] Description of the unit parts: 1.) Power cable & mains plug 5.) Air inlet & air filter 2.) Humidity sensor 6.) Carrying handle 3.) Air outlet / air guide fin 7.) Control panel 4.) Condensation tank 8.) Humidity LED 1.) 3.) 4.) 5.) 6.) 7.) 8.) Air filter Activated carbon filter 2.) Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: [email protected] Functional description: 1.) Signal lights of the selected air circulation strength 8.) DRY button for selecting the "turbo mode 2.) Display screen 9.) Humidity button for setting the air humidity 3.) "Timer activated" signal light 10.) Operating light 4.) Button for selecting the "Auto mode 11.) On/Off switch 5.) "Air purification active" signal light 12) "Condensation tank full" signal light 6.) Button for selecting air circulation 13.) Timer button for setting the timer running time 7.) "Turbo mode" signal light 14.) Button for activating air cleaning (AIR CLEAN) Optional > HEPA filter required (see 1.5) Instructions for use: 1. Commissioning 1.1. Insert the mains plug properly into the socket. 1.2. Check that the condensation tank is properly seated in the dehumidifier. When using the dehumidifier for the first time, the "condensation tank full" light may come on. Simply pull the condensation tank out briefly and then push it back in again and you are ready to go! 1.3. Open the air guide vane at the air outlet of your dehumidifier and then switch the unit on with the "On/Off switch". The dehumidifier starts its operation with a target value of 50% r.l. and a weak air circulation. Now press the Humidity button to set the desired humidity. Press the Humidity button several times to set your target humidity as desired between 40% - 70% RH. The target value you have set flashes on the display for approx. 5 seconds. After that, the current room humidity is displayed again. The target value "Co" corresponds to continuous operation ! If the room humidity is below 35% when continuous operation is activated, the unit operates for approx. 15 minutes and then pauses briefly. This cycle continues until the humidity rises above 35% again. In addition to the display, the current room humidity is also indicated by the humidity LED. The LED lights up in three different colours: Blue = High humidity > 70% r.l. Green = Medium humidity ~ 50 - 70% r.l. Red = Low humidity < 50% r.l. 1.) 2.) 3.) 10.) 11.) 12.) 9.) 4.) 5.) 6.) 8.) 13.) 7.) 14.)