alpro AS626S Manuals
1 pdf manual(s) alpro AS626S for free download (Document Types: Manual )
alpro AS626S Manual [PDF] (2 pages)
- Identifier: id-1289775
- Brand: alpro
- Device: AS626S Keypad
- Type: PDF
- Key Aspects: Recommended Spare Parts List, Detailed Installation Instructions, Cleaning and Sanitization Methods
- UPD Date: 22.03.2026
- Source File: 1297927.pdf
- Pages: 2
- Description: User reference guide for the alpro AS626S.
Click to expand and read text
Waterproof Keypad AS626S Read all instructions before starting installation Connect keypad using wiring description. Wiring description Power 12 or 24v AC or DC (AC does not have a polarity) Brown + Positive Blue - Negative Output Relay Max 2amp @ 24v Grey Common Red Selectable – Relay NO or NC (Default is set to NO) To change see 7 & 8 under ‘Programming the Keypad’ Contact 2 Amp. Dry contact for Door Strike Exit Button Push to make – Volt free White/Pink Exit Button (NO) Power Consumption Stand by – Approximately 25 milliamps @12vDC Operation – Approximately 80 milliamps @12vDC For 12vDC inductive loads such as electric strikes and electromagnetic locks, the enclosed 12vDC metal oxide varistor must be connected in parallel with the load, at the load terminals and not in the keypad. Ensure power supply is of correct rating, taking into account the current requirements of the locking items and accessories. Do not insert security plugs into fixing holes until all installation and testing has been completed. These items require drilling out and cannot be re-fitted. LED signalling explanation GREEN LED Door Strike activated (unlocked) RED LED Normal Operation: 3 sec. ON = wrong Code Entry Slow flashing = wrong code entry 3 times Programming Mode: Fast flashing = programming different functions Slow flashing = programming stand-by Very fast flashing = erasing all user codes The door remote opening (via exit switch) is possible when a dry contact is made between the wires White and Orange. The lock is activated for the time the system is programmed. Factory set @ 5 seconds. Remote opening is disabled during programming and latch mode. Apply power to the keypad. The keypad’s buzzer will sound briefly, the Red LED will illuminate briefly Initialisation is now complete, with a default master code of 1-2-3-4 and a 5-second open door. PACK CONTENTS MOUNTING INSTRUCTIONS ACTIVATION TESTING THE UNIT PROGRAMMING THE KEYPAD TROUBLE SHOOTING INITIALISATION Connect to + of Locking Device Connect to - of Locking Device Breakglass Pink White Brown Blue Grey Red Power Supply Exit Button Enter the master code [1 2 3 4 #] The Door Relay changes its contacts for 5 sec. The Green LED will light up for 5 sec. Repeat this step 2,3 times. If the master code is wrongly typed in, the Red LED lights up for 3 sec. re- enter the Code as soon as the LED goes OFF. IMPORTANT: CHANGE THE FACTORY SET MASTER CODE WHEN YOU PROGRAM YOUR UNIT FOR USE. THERE IS NO WAY TO RECOVER THE NEW MASTER CODE IF IT IS LOST OR FORGOTTEN. THE UNIT CAN BE RESET TO FACTORY PRESETS AND CUSTOMISED AGAIN. See Data Reset Enter H H1 2 3 4 H H The keypad enters programming mode, the Red LED flashes If no further information is added, the unit will revert to normal operation after a 3 second delay. To exit programming press #. There are six programming options: - 1. Set new master code It is suggested the Master Code is not changed until person programming is familiar with all aspects of programming the keypad! 2. Set new user code 3. Erase a user code 4. Erase all user codes 5. Set door open time (1-99s) 6. Set output to latch option Continued over... The keypad does not “respond” when activating the keys. 1. Make sure the electronic unit has been properly wired to the PSU and the power has not been cut-off. The keypad “responds” but the door does not open. 1. Make sure the Green LED is illuminated. 2. If not, the entered code has not been programmed yet. Please refer to “Programming”. 3. Enter the Master Code and make sure the door opens correctly. If not, check the wiring and the Lock’s integrity. 1 3 5 7 9 * 2 4 6 8 0 # x2 x2
alpro AS626S: Keypad Category Related Instructions
0 | For gamers. by gamers™ The Razer Tartarus Chroma gaming keypad comes with 25 anti-ghosted fully programmable keys including an 8-way thumb-pad for complete control and maneuverability over your game. Its ergonomic form factor includes an adjustable wrist Detailed operating instructions for the Razer tartarus chroma Keypad. This documentation provides step-by-step guidance on technical overview, interface navigation, shutdown procedures, firmware updates.
1 Product operation guide for the IntelliSense EDS-18P Keypad. The document contains device calibration, service contacts, assembly reference, system configuration.
© Nicolaudie-Sunlite 1989-2017. All rights reserved. We reserve the right without notice to amend the technical information and specifications. STICK-DE3 Sunlite Touch Sensitive Intelligent Control Keypad http://www.nicolaudie.com/stick-de3.htm Key Features Comprehensive instruction manual for the Nicolaudie STICK-DE3 Keypad. The document contains software updates, troubleshooting tips, error handling, firmware installation.
Skip to content Manuals+ User Manuals Simplified. Keypad user guide. Print Home » Support » Keypad user guide. Print Popp Keypad. Operating handbook for the Aeotec Popp Keypad. The manual highlights component overview, device calibration, network setup, cleaning instructions.