Altronics FOTEK NT-RV Series Manuals

1 pdf manual(s) Altronics FOTEK NT-RV Series for free download (Document Types: Instruction manual)

Altronics FOTEK NT-RV Series Instruction manual [PDF] (5 pages)

  • Identifier: id-2025891
  • Brand: Altronics
  • Device: FOTEK NT-RV Series Controller
  • Type: PDF
  • Key Aspects: Model Variations and Compatibility, Basic Configuration Guidelines, Efficiency and Calibration Tips
  • UPD Date: 19.03.2026
  • Source File: 2261967.pdf
  • Pages: 5
  • Description: Manual for safe operation of the Altronics FOTEK NT-RV Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
■ Specification / Especificaciones: Type DIN 48*48 DIN 72*72 /48*96 /96*96 DIN 24*48 Model NT-48RV-AF NT-XX-RV-AF NT-10-AF Output method Relay & SSR Relay or SSR Rated current Relay (5A/250VAC);SSR(30mA/12V) Operating voltage 90~265VAC 50/60Hz Alarm output Relay (5A/250VAC) Control method PID + Fuzzy Input method PT / K / J / R / S / T/ B / E / N / L Selectable Display range -999 ~ 9999 或 -99.9 ~ 999.9 Selectable Accuracy of display ± ( 0.1 % of F.S. + 1 DIGIT) Setting range -999 ~ 9999 或 -99.9 ~ 999.9 Selectable Dielectric strength Over 2.5KV Isolation strength Over 100MΩ / 500VDC Operating temp ﹣20℃ ~ ﹢80℃;35 ~ 85%RH Housing material Intensive PC+ABS(UL-94V0) ■ Mode of alarm / Modos de Alarma ALt Description / Descripción ALt Description / Descripción ALt Description / Descripción 0 AL1 ON SV (SV+AL1) AL2 ON SV (SV+AL2) 1 AL1 ON (SV - AL1) SV AL2 ON SV (SV+AL2) 2 AL1 ON (SV - AL1) SV AL2 ON (SV – AL2) SV 3 AL1 ON (SV – AL2) SV (SV+AL1) AL2 ON SV (SV+AL2) 4 AL1 ON (SV – AL1) SV (SV+AL1) AL2 ON SV (SV+AL2) 5 AL1 ON (SV - AL1) SV (SV+AL1) AL2 ON SV (SV+AL2) 6 AL1 ON AL1 AL2 ON AL2 7 AL1 ON First cycle unable AL1 AL2 ON AL2 8 AL1 ON First cycle unable (SV - AL1) SV AL2 ON SV (SV+AL2) 9 AL1 ON First cycle unable (SV - AL1) SV (SV+AL1) AL2 ON SV (SV+AL2) 10 AL1 ON SV (SV+AL1) AL2 ON SV tnr 99h59m 11 AL1 ON AL1 AL2 ON AL2 12 AL1 ON AL1 AL2 ON AL2 13 AL1 ON SV (SV+AL1) AL2 ON (SV – AL2) SV 14 AL1 ON SV (SV+AL1) AL2 ON (SV – AL2) SV 15 AL1 ON 1 Flicker SV (SV+AL1) AL2 ON SV (SV+AL2) 16 AL1 ON SV (SV+AL1) AL2 ON SV tnr 99h59m 17 AL1 ON SV (SV+AL1) AL2 ON SV tnr 99m59s 18 AL1 ON SV (SV+AL1) AL2 ON SV tnr 99m59s 19 Non-used 20 AL1 ON 1 Flicker SV (SV+AL1) AL2 ON SV (SV+AL2) 21 AL1 ON 1 Flicker SV (SV+AL1) AL2 ON First cycle unable (SV - AL1) SV (SV+AL2) 22 AL1 ON 1 Flicker SV (SV+AL1) AL2 ON (SV - AL1) SV 23 AL1 ON 1 Flicker SV (SV+AL1) AL2 ON (SV - AL1) SV 24 AL1 ON 1 Flicker SV (SV+AL1) AL2 ON (SV - AL1) SV (SV+AL2) 25 AL1 ON 1 Flicker SV (SV+AL1) AL2 ON (SV - AL1) SV (SV+AL2) 26 AL1 ON AL1 SV AL2 ON First cycle unable (SV – AL2) SV 1.「ALt=15」:t = ON time of AL2 for cooling, OFF time is controlled by PID. 2.「ALH」:Hysteresis of alarm. Ex. PV≧(SV+AL1)→AL1 ON, PV<(SV+AL1-ALH)→AL1 OFF 3.「tnu」= Process time of tnr, if「tnu≧tnr」→ AL2 is turned ON or OFF UL CE RoHs Instruction Manual / Manual de Uso F - 71 NT-XX-RV-AF series All function temperature controller Thank you very much for using FOTEK NT-XX-RV series All function Temperature controller Please read this instruction manual before operating it to avoid from the malfunction. FOTEK NT10-R-AF / NT-22-R-AF / NT-48RV / NT-72-RV / NT-20-RV / NT-21-RV / NT96-RV-AF AlltronicsPerú AUTOMATIZACIÓN INDUSTRIAL https://www.fotek.com.tw https://alltronicsperu.com