Amana RHA48B2A Manuals

1 pdf manual(s) Amana RHA48B2A for free download (Document Types: Specification sheet)

Amana RHA48B2A Specification sheet Thumbnail

Amana RHA48B2A Specification sheet [PDF] (2 pages)

  • Identifier: id-118201
  • Brand: Amana
  • Device: Amana RHA48B2A Heat Pump
  • Type: Specification sheet, PDF
  • Key Aspects: Technical Support and Resource Links, Additional Modules and Accessories Guide, Initial Startup Checklist
  • UPD Date: 17.05.2026
  • Source File: 24487.pdf
  • Pages: 2
  • Description: General instruction manual for the Amana RHA48B2A.
Pages Preview:
  • Amana RHA48B2A Specification sheet preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
RHA48B2A Remote Heat Pump NOTE: It is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accor- dance with all national and/or local electrical codes. Use copper wire only. Specification Sheet Due to policy of continual product improvement, the right is reserved to change specifications and design without notice. Standard Features • Bi-Flow Liquid Line Drier (Shipped Loose) • Front Seating Valves • 5 Minute Anti-Short Cycle Protection • Time-Temperature Defrost System • Low RPM (825) Condenser Fan • Scroll Compressor • Accumulator Accessories • Pressure Control Kit (PCK02A) Automatic Reset High Pressure Switch Time Delay • Fossil Fuel Kit (FFK03A) • Compressor Sound Blanket (CSB07A) • Ambient Temperature Kit (ATK05) • Low Ambient Control (LAC03A) When mix matching with restrictor orifice indoor coil, use restrictor orifice part number B1443805 or 11076312, 0.084” diameter. NOTE: Defrost control compressor run time is factory set at 90 minutes. Heat Pump Performance Data For ARI Performance Data: See the ARI Directory, Product Data Booklet (PDB), or the product Service Manual. June 1998 20209806 Above information is for nominal CFM and 70° F indoor dry bulb. All pressures are PSIG. All temperatures are °F. Amps are outdoor unit amps. Low pressure is measured at the gauge port. High pressure is measured at the liquid service valve. A higher standard of comfort Heating ¡ Air Conditioning ® Amana Fayetteville, TN 37334 Specifications Cooling Capacity, BTUH (Nominal) 48,000 Compressor R.L. Amps 24.6 L.R. Amps 131 Condenser Fan Motor Horsepower 1/4 R.L. Amps 1.7 L.R. Amps 3.3 Liquid Line, Inches O.D. 3/8 Suction Line, Inches O.D. 7/8 Refrigerant Charge (oz) 181 Power Supply 208/230-60-1 Min Circuit Ampacity 32.4 Max Overcurrent Device 50 Electric Conduit Size (in) Power Supply 1/2 or 3/4 Low Voltage 1/2 Approximate Shipping Weight (Lbs) 170 Outdoor Ambient Temperature (° F) 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 ∆T 33 32 30 28 27 26 24 22 22 20 19 18 17 15 13 12 10 8 Amps 24.5 22.6 21.2 19.9 19.2 18.8 17.7 16.8 16.0 15.3 14.6 14.2 14.0 13.3 12.4 11.7 10.7 9.6 HI PR 266 255 245 234 229 224 216 207 198 189 182 177 174 168 161 155 149 144 LO PR 71 66 62 56 53 51 47 42 38 34 30 28 27 23 19 16 14 11 RHA48B2A / BBA60A2A / CCA57FCC

Similar Manuals in the Heat Pump Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
LG LC188HHV4

PDF Manual (@AA6PS2), LG LC188HHV4 Heat Pump (21-05-2026)

74 989 159 21-05-2026 view all manuals
Conair 10

Manual: Conair 10 (RJ73K9, Upd.07-04-2026)

10 0.23 Mb 875 140 07-04-2026 view all manuals
Regulus CSE2 F W 1F

Water Pump #WQMAE3

16 1197 180 04-08-2026 view all manuals
Panasonic CS-E18NKUA

Panasonic CS-E18NKUA User Guide (Service manual), @T1Y3E3

82 394 71 09-05-2026 view all manuals
Danfoss DHP-iQ

Heat Pump #VG958P

56 741 126 25-03-2026 view all manuals
Daikin UWL-B5 Series

UWL-B5 Series Catalogue/engineering data - 4EW434

48 1431 215 27-06-2026 view all manuals