Amana RHA48B2A Manuals
1 pdf manual(s) Amana RHA48B2A for free download (Document Types: Specification sheet)
Amana RHA48B2A Specification sheet [PDF] (2 pages)
- Identifier: id-118201
- Brand: Amana
- Device: Amana RHA48B2A Heat Pump
- Type: Specification sheet, PDF
- Key Aspects: Technical Support and Resource Links, Additional Modules and Accessories Guide, Initial Startup Checklist
- UPD Date: 17.05.2026
- Source File: 24487.pdf
- Pages: 2
- Description: General instruction manual for the Amana RHA48B2A.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
RHA48B2A Remote Heat Pump NOTE: It is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accor- dance with all national and/or local electrical codes. Use copper wire only. Specification Sheet Due to policy of continual product improvement, the right is reserved to change specifications and design without notice. Standard Features • Bi-Flow Liquid Line Drier (Shipped Loose) • Front Seating Valves • 5 Minute Anti-Short Cycle Protection • Time-Temperature Defrost System • Low RPM (825) Condenser Fan • Scroll Compressor • Accumulator Accessories • Pressure Control Kit (PCK02A) Automatic Reset High Pressure Switch Time Delay • Fossil Fuel Kit (FFK03A) • Compressor Sound Blanket (CSB07A) • Ambient Temperature Kit (ATK05) • Low Ambient Control (LAC03A) When mix matching with restrictor orifice indoor coil, use restrictor orifice part number B1443805 or 11076312, 0.084” diameter. NOTE: Defrost control compressor run time is factory set at 90 minutes. Heat Pump Performance Data For ARI Performance Data: See the ARI Directory, Product Data Booklet (PDB), or the product Service Manual. June 1998 20209806 Above information is for nominal CFM and 70° F indoor dry bulb. All pressures are PSIG. All temperatures are °F. Amps are outdoor unit amps. Low pressure is measured at the gauge port. High pressure is measured at the liquid service valve. A higher standard of comfort Heating ¡ Air Conditioning ® Amana Fayetteville, TN 37334 Specifications Cooling Capacity, BTUH (Nominal) 48,000 Compressor R.L. Amps 24.6 L.R. Amps 131 Condenser Fan Motor Horsepower 1/4 R.L. Amps 1.7 L.R. Amps 3.3 Liquid Line, Inches O.D. 3/8 Suction Line, Inches O.D. 7/8 Refrigerant Charge (oz) 181 Power Supply 208/230-60-1 Min Circuit Ampacity 32.4 Max Overcurrent Device 50 Electric Conduit Size (in) Power Supply 1/2 or 3/4 Low Voltage 1/2 Approximate Shipping Weight (Lbs) 170 Outdoor Ambient Temperature (° F) 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 ∆T 33 32 30 28 27 26 24 22 22 20 19 18 17 15 13 12 10 8 Amps 24.5 22.6 21.2 19.9 19.2 18.8 17.7 16.8 16.0 15.3 14.6 14.2 14.0 13.3 12.4 11.7 10.7 9.6 HI PR 266 255 245 234 229 224 216 207 198 189 182 177 174 168 161 155 149 144 LO PR 71 66 62 56 53 51 47 42 38 34 30 28 27 23 19 16 14 11 RHA48B2A / BBA60A2A / CCA57FCC
Similar Manuals in the Heat Pump Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
LG LC188HHV4 |
PDF Manual (@AA6PS2), LG LC188HHV4 Heat Pump (21-05-2026) |
74 | 989 | 159 | 21-05-2026 | view all manuals | |
Conair 10 |
Manual: Conair 10 (RJ73K9, Upd.07-04-2026) |
10 | 0.23 Mb | 875 | 140 | 07-04-2026 | view all manuals |
Regulus CSE2 F W 1F |
Water Pump #WQMAE3 |
16 | 1197 | 180 | 04-08-2026 | view all manuals | |
Panasonic CS-E18NKUA |
Panasonic CS-E18NKUA User Guide (Service manual), @T1Y3E3 |
82 | 394 | 71 | 09-05-2026 | view all manuals | |
Danfoss DHP-iQ |
Heat Pump #VG958P |
56 | 741 | 126 | 25-03-2026 | view all manuals | |
Daikin UWL-B5 Series |
UWL-B5 Series Catalogue/engineering data - 4EW434 |
48 | 1431 | 215 | 27-06-2026 | view all manuals |