AMPLITUDE Magma 200 Manuals

2 pdf manual(s) AMPLITUDE Magma 200 for free download (Document Types: Quick troubleshooting manual, Startup procedure)

AMPLITUDE Magma 200 Quick troubleshooting manual [PDF] (8 pages)

  • Identifier: id-1751405
  • Brand: AMPLITUDE
  • Device: Magma 200 Measuring Instruments
  • Type: PDF
  • Key Aspects: Unpacking and Inspection Guidelines, Recommended Spare Parts List, Best Practices for Everyday Use
  • UPD Date: 18.06.2026
  • Source File: 1788876.pdf
  • Pages: 8
  • Description: Device instruction guide for the AMPLITUDE Magma 200.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Magma 200 Quick troubleshooting guide Version 1.00 1 Headquarters / 11 avenue de Canteranne, Cité de la Photonique - Bâtiment MEROP A 33600 Pessac - France Amplitude Laser Group / Capital social: 317 100 € / Siret 434 637 005 - APE 6420Z / N°TVA Intracom: FR 70 434 637 005 Tel: +33 (0)5 56 46 40 60 / Fax: +33 (0)5 56 46 06 94 / [email protected] / www.amplitude-laser.com Headquarters / 11 avenue de Canteranne, Cité de la Photonique - Bâtiment MEROPA 33600 Pessac - France Amplitude Laser Group / Capital social : 320 925 € / SIRET: 434 637 005 - APE 6420Z / N°TVA Intracom: FR 70 434 637 005 Tel: +33 (0)5 56 46 40 60 / Fax: +33 (0)5 56 46 06 94 / [email protected] / www.amplitude-laser.com Quick troubleshooting (Nothing will ever go wrong, but just in case here are some possible solutions) Table of contents 1. Errors, interlocks and safeties ............................................................................................ 2 1.1. Magma 25 .................................................................................................................... 2 1.1.1. Safety window ...................................................................................................... 2 1.1. Diodes .......................................................................................................................... 2 1.1.1. Interlocks .............................................................................................................. 2 1.2. Chillers ......................................................................................................................... 3 1.2.1. Water level ........................................................................................................... 3 1.2.2. Temperature ......................................................................................................... 4 1.2.3. Flow ...................................................................................................................... 4 1.3. Deionising unit ............................................................................................................. 4 1.3.1. Water flow ............................................................................................................ 4 1.3.2. Water resistivity ................................................................................................... 4 1.4. High voltage unit .......................................................................................................... 4 2. No output from the Regenerative amplifier ...................................................................... 4 2.1. Easy checks .................................................................................................................. 4 2.1.1. There is something in front of the diagnostic cameras ....................................... 4 2.1.2. Oscillator is not started ........................................................................................ 4 2.1.3. Synchronisation signals ........................................................................................ 5 2.1.4. Pump diode is not on ........................................................................................... 5 2.1.5. Shutter is closed. .................................................................................................. 5 2.1.6. Room temperature ............................................................................................... 5 2.1.7. PulseShaper not set .............................................................................................. 6 2.1.8. External devices .................................................................................................... 6 2.2. Hard checks .................................................................................................................. 6 2.2.1. Input seed pulse in the regen amplifier ............................................................... 6 3. Device not responding ....................................................................................................... 7 3.1. Compressor translation or rotation not responding ................................................... 7 3.2. Motorised mounts in the amplifiers not responding .................................................. 7

AMPLITUDE Magma 200 Startup procedure [PDF] (24 pages)

  • Identifier: id-1748741
  • Brand: AMPLITUDE
  • Device: Magma 200 Measuring Instruments
  • Type: PDF
  • Key Aspects: Periodic Inspection Checklists, Additional Modules and Accessories Guide, Regulatory Compliance and Standards
  • UPD Date: 16.06.2026
  • Source File: 1791541.pdf
  • Pages: 24
  • Description: Comprehensive setup guide for the AMPLITUDE Magma 200.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
CFEL – Magma 200 Amplitude Laser Start-up procedure