Anton Sprint Pro 2 Manuals
1 pdf manual(s) Anton Sprint Pro 2 for free download (Document Types: Quick start manuals)
Anton Sprint Pro 2 Quick start manuals [PDF] (2 pages)
- Identifier: id-838831
- Brand: Anton
- Device: Sprint Pro 2 Measuring Instruments
- Type: PDF
- Key Aspects: Periodic Inspection Checklists, Standard Operating Procedures, Glossary of Technical Terms
- UPD Date: 24.07.2026
- Source File: 800930.pdf
- Pages: 2
- Description: Operating instructions for the Anton Sprint Pro 2.
Click to expand and read text
Anton Industrial Services Limited Unit 6 Greenhill House, 26 Greenhill Crescent, Watford Business Park, Watford WD18 8JA Tel. No: +44 (0)870 428 0075 Website: www.anton-group.com Email: [email protected] Part number: INS29504 Issue 1 September 2018 Page 1 of 2 Quick Start Guide - Sprint Pro 2 - 6 IMPORTANT NOTES: Please read the user manual for full instructions on the use of Sprint Pro this guide should be used for a quick reference only (full user manual is available at www.anton-group.com). Observe all warnings and instructions detailed in the user manual or as prompted by the analyser. Before use ensure Sprint Pro is in good repair and do not use if damaged or if calibration has expired. Sprint Pro must only be used with the Sprint Pro Flue Probe Assembly and always with the water trap and filters in place. The water trap must be dried after use and before Sprint Pro Flue Probe Assembly is returned to carry case. Connect the Flue Probe Assembly to Sprint Pro before switching on and do not insert probe into flue until after the zeroing process is complete. Always start Sprint Pro in clean air. Sprint Pro will lock out its Test Menu once calibration has expired. SWITCH-ON Press and hold the ON/OFF/ENTER key for two seconds until you hear two beeps. Ensure the gas exhaust outlet on the side of the FGA is not blocked. After warm-up is complete, Sprint Pro will display the Main Menu screen. You can now navigate the menu system using the and soft keys and the and ESC keys on the analyser. SWITCH-OFF Press and hold the ON/OFF/ENTER button for approximately two seconds until you hear a rising beep. Press the ESC key to abort switch off sequence and return to Test Menu. Note: Unit will purge and shut down once purge complete. Charging battery PERFORMING TESTS To enter any test screen, select the required test from the menu and use the soft key marked or . To end any test, press the ESC key. FLUE GAS ANALYSIS Select Flue gas analysis from the Test Menu. The first time this option is entered after each switch on the Sprint Pro will perform a ‘zero’. Following a successful ‘zero’, Sprint Pro will begin taking measurements. Use the soft keys to log or print the results. Press the ON/OFF/ENTER button to display the various screens available: Screen 1: O2, CO, CO2, CO/CO2 ratio and pressure Screen 2: O2, excess (XS) air, Temperature Flue and Efficiency Screen 3: Combines flue elements from previous screens. Screen 4: (if NO sensor not fitted): Temperature Flue, Temperature Inlet, Net Temperature Screen 4: (if NO sensor fitted): NO, NOx, CO, CO2, CO/CO2 Ratio, O2 Screen 5: (if NO sensor fitted): Temperature Flue, Temperature Inlet, Net Temperature To perform a manual pressure ‘zero’, use the soft key marked in flue gas screen 1 or 3. To change the efficiency readings (Net, Gross – for NetHE see user manual), use the soft key marked η in flue gas screen 2. Note: The pump will remain on and continue purging for some time after leaving this option to clear residual gas PRESSURE AND DIFFERENTIAL PRESSURE TESTS Before carrying out the test, the pressure must be zeroed with the tubes connected to the instrument but not to the pressure source. A thermocouple may be connected to provide temperature readings in these tests. 1. Select Pressure Menu from the Test Menu. Then select Pressure or Diff Pressure from the menu. 2. Connect tubes to pressure inlets on instrument. 3. Zero pressure using the soft key marked . 4. Connect tube(s) to pressure source(s) to begin differential pressure tests. Sprint Pro will give a warning if the pressure points are the wrong way round. 5. There is an option to time this test: Sprint Pro will display the duration time on the screen. Press the soft key to start optional timer. To stop timer press the soft key To reset the timer press the soft key then . 6. To re-zero the pressure at any time press LET-BY, STABILISATION AND TIGHTNESS TEST 1. Select Pressure Menu from the Test Menu. From the Pressure Menu select Let-by / Tightness. 2. Connect tube to positive pressure inlet on the instrument. 3. Zero pressure, using the soft key marked Summary of screen icons Select, pick or action Up item or entry Down item or entry Left field Right field Zero pressure Start timed test Stop timed test Restart timed test Yes, pass or done No or fail or cancel Purge or pump running icon Select temp 1 (flow) (Differential Temperature Test) Select temp 2 (return) (Differential Temperature Test) Save log Export report/log to IR Printer Export report/log to Mobile App Delete Edit value Increase value Decrease value Descend through character list (string edit) Ascend through character list (string edit) CO Alarm Select Net/Gross/NetHE Efficiency IR Printer Alignment
Sprint Pro 2: Measuring Instruments Category Related Instructions
®® AN ISO 9001:2015 COMPANY MODEL - KM 033 OPERATION MANUAL G 17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct : (0 Full operation manual for the Kusam-meco KM 033 Measuring Instruments. This guide elaborates on device features and service instructions, setup validation, system configuration, safety precautions.
MENU INDIRECT INDIRECT SETTINGS UNITS AUDIO LANGUAGE MENU INDIRECT INDIRECT SETTINGS UNITS AUDIO LANGUAGE MENU INDIRECT INDIRECT SETTINGS UNITS AUDIO LANG Operating and setup manual for the Milwaukee LDM 45 Measuring Instruments. The manual contains instructions for replacement parts, calibration steps, software configuration.
BC-8S Battery Checker BC-8S User manual Ver 1.1.112 Battery Checker BC-8S Installation guide for the ISDT BC-8S Diagnostic Equipment. It explains usage scenarios and technical assistance, security instructions, operating conditions.
DOC022.98.80058 H160, H170 10/2013, Edition 1 User Manual Bedienungsanleitung Manuel d'utilisation Uživatelská příručka Brugsanvisning Instrukcja obsługi Operation guide for the Hach H160 Measuring Instruments. It offers guidance on energy usage, device instructions, safety precautions, safety information.