ANTTI 408050 Manuals

1 pdf manual(s) ANTTI 408050 for free download (Document Types: Installation and operating instructions manual)

Document Preview & Text Transcription

Installation and Operating Instructions Scale 408050 (en) ANTTI-TEOLLISUUS OY Koskentie 89 25340 KANUNKI Puhelin (02) 774 4700 E-mail: antti-teollisuus.fi www.antti-teollisuus.fi 01-2020 3 Antti-Teollisuus Oy Scale 01-2020 INSTALLING THE SCALE SENSORS The sensors delivered by Antti-Teollisuus incorporate complete kit for installation in the dryer base leg. At least 2 sensors are required in order to achieve a measuring accuracy of ±100 kg. If scale sensors are installed under each leg (4 pcs. in all), in theory a meas- uring accuracy of 1 kg can be achieved. This requires that pipes to and from the dryer be equipped with flexible parts. The dryer in which the sensors are installed must be located indoors and must not come in contact with any other structures of the dryer. Note! If 2 sensors are installed, they must be located under legs on the same side of the dryer (see Illustration). Scale sensor Base Base Antti-Teollisuus delivers scale sensors with capacity of 20 000 kg. Thus total weight of dryer may be 80 000 kg. Slight exceeding may only cause minor inaccuracy in measuring results. To install the scale sensors, the dryer legs must be shortened by 121,5 mm (see illustra- tion on the next page). Base viewed from above 4 Scale 01-2020 Antti-Teollisuus Oy