Installation and
Operating Instructions
Scale
408050 (en)
ANTTI-TEOLLISUUS OY
Koskentie 89
25340 KANUNKI
Puhelin (02) 774 4700
E-mail: antti-teollisuus.fi
www.antti-teollisuus.fi
01-2020
3
Antti-Teollisuus Oy
Scale
01-2020
INSTALLING THE SCALE SENSORS
The sensors delivered by Antti-Teollisuus incorporate complete kit for installation in the
dryer base leg. At least 2 sensors are required in order to achieve a measuring accuracy
of ±100 kg. If scale sensors are installed under each leg (4 pcs. in all), in theory a meas-
uring accuracy of 1 kg can be achieved. This requires that pipes to and from the dryer be
equipped with flexible parts. The dryer in which the sensors are installed must be located
indoors and must not come in contact with any other structures of the dryer.
Note! If 2 sensors are installed, they must be located under legs on the same side of the
dryer (see Illustration).
Scale sensor
Base
Base
Antti-Teollisuus delivers scale sensors with capacity of 20 000 kg. Thus total weight of
dryer may be 80 000 kg. Slight exceeding may only cause minor inaccuracy in measuring
results.
To install the scale sensors, the dryer legs must be shortened by 121,5 mm (see illustra-
tion on the next page).