API DuoPak APD 2067 Manuals

1 pdf manual(s) API DuoPak APD 2067 for free download (Document Types: Quick start manual)

API DuoPak APD 2067 Quick start manual Thumbnail

API DuoPak APD 2067 Quick start manual [PDF] (2 pages)

  • Identifier: id-2202424
  • Brand: API
  • Device: API DuoPak APD 2067 Transmitter
  • Type: Quick start manual, PDF
  • Key Aspects: Operational Mode Explanations, Documentation and Revision History, Information on Regular Maintenance
  • UPD Date: 31.05.2026
  • Source File: 2085208.pdf
  • Pages: 2
  • Description: Complete technical documentation for the API DuoPak APD 2067.
Pages Preview:
  • API DuoPak APD 2067 Quick start manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
api-usa.com 1220 American Way Libertyville, IL 60048 Phone: 800-942-0315 Fax: 800-949-7502 BSOLUTE ROCESS NSTRUMENTS, Inc. © 05-16 Removable Plugs Dimensions 1.78" W x 4.62" H x 4.81" D 45 mm W x 117 mm H x 122 mm D Height includes connectors Sink or Source mA Output for Each Channel Output LoopTracker LED for Each Channel Adjustable Output Test Function for Each Channel Zero and Span for Each Channel Sensor Power Available for Frequency Input Custom I/O Ranges Description The APD 2067 DuoPak accepts one AC voltage or current input and one frequency input and provides two optically isolated DC voltage or current outputs that are linearly related to the inputs. The input ranges and the output ranges for each channel are independent and can be specified as required. This provides an economical two channel solution in one device. Typical applications include signal conversion, isolation, and redundancy (i.e. to prevent failure of the entire loop if one device fails), or a combination of these. Each input signal is filtered, amplified, and then passed through an opto-coupler to the output stages. Full 5-way isolation (input 1, input 2, output 1, output 2, power) make this module useful for ground loop elimination, common mode signal rejection, and noise pickup reduction. Output Sink/Source Versatility Standard on the APD 2067 are 20 VDC loop excitation sup- plies for each output channel. These power supplies can be selectively wired for sinking or sourcing allowing use with any combination of powered or unpowered milliamp I/O devices. LoopTracker API exclusive features include four LoopTracker LEDs (green for each input, red for each output) that vary in intensity with changes in the process input and output signals. These provide a quick visual picture of your process loop at all times and can greatly aid in saving time during initial startup and troubleshooting. Output Test An API exclusive feature includes output test buttons for each channel to provide a fixed output (independent of the input) when held depressed. Terminals are also provided to operate the test functions remotely for each channel. This also allows use as a remote manual override to provide a temporary fixed output if desired. The test output level for each channel is potentiometer adjust- able from 0 to 100% of the output span. The output test greatly aids in saving time during initial startup and/or troubleshooting. Universal Power Input LoopTracker LED for Each Channel O Two Independent Channels with Full Isolation O Zero and Span for Each Output O Input and Output LoopTracker ® LEDs O Output Test/Manual Override for Each Channel O Built-In I/O Power Supplies Q Monitor AC Voltage or Current and Speed Q Convert/Isolate Dual Output Transmitters Applications Channel 1 AC Input Range Factory configured, please specify input type and range Voltage: 0-50 mVAC to 0-300 VAC Current: 0-1 mAAC to 0-1000 mAAC Measurement type: True RMS Frequency: 40 Hz to 1000 Hz sinusoidal Voltage input impedance: 220 kΩ minimum Current input voltage burden: 1.0 VRMS maximum Channel 2 Frequency Input Range Factory configured, please specify input range Frequency: 0-25 Hz to 0-20 kHz Any waveform with 5 microsecond min. pulse, 100 mV min. amplitude change, 100 mV to 150 VRMS amplitude Channel 2 Sensor Power Supply 15 VDC ±10%, regulated, 25 mADC, <10 mVRMS max. ripple Channel 2 Characteristics Impedance at max. sensitivity: 10 kΩ nom. Impedance at min. sensitivity: 100 kΩ nom. Sensitivity/hysteresis adjustment: Multi-turn potentiometer Sensitivity/hysteresis range: ±25 mV to ±2.5 V typical Normal mode protection: 200% of input rating Common mode protection: 600 V input to ground LoopTracker Variable brightness LEDs indicate I/O levels for each channel Channel 1 and Channel 2 Output Ranges Factory configured, please specify for each output channel Voltage: 0-1 VDC to 0-10 VDC, 10 mA max up to 20 VDC with M19, M29, M39 Bipolar voltage: ±1 VDC to ±10 VDC Current: 0-1 mADC to 0-25 mADC, 4-20 mADC 20 V compliance, 1000 Ω at 20 mA Output Calibration Multi-turn zero and span potentiometers for each output channel ±15% of span adjustment range typical Characteristics Accuracy: ±0.1% of span (incl. adj. resolution and linearity) Output ripple and noise: Less than 10 mVRMS Isolation: Full 5-way, 1200 VRMS minimum Response Time 70 milliseconds typical Ambient Temperature Range and Stability –10°C to +60°C ambient, better than 0.04% span/°C stability Output Loop Power Supplies 20 VDC nominal, regulated, 25 mADC for each output channel May be selectively wired for sinking or sourcing mA output Output Test Front buttons set each output to test level when pressed Each test level potentiometer adjustable 0-100% of span Housing and Connectors IP 40, requires installation in panel or enclosure For use in Pollution Degree 2 Environment Mount vertically to a 35 mm DIN rail Eight 4-terminal removable connectors, 14 AWG max wire size Power 85-265 VAC, 50/60 Hz or 60-300 VDC, 6 W maximum D versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 6 W maximum ® Two Channel Signal Converter/Isolator/Transmitter APD 2067 Channel 2: Frequency to DC Channel 1: AC to DC Options—add to end of model number R1 Channel 1 I/O reversal (i.e. 20-4 mA out) R2 Channel 2 I/O reversal (i.e. 20-4 mA out) R3 Channel 1 and channel 2 I/O reversal M19 Channel 1 high voltage output >10 V up to 20 V M29 Channel 2 high voltage output >10 V up to 20 V M39 Channel 1 and channel 2 high voltage output U Conformal coating for moisture resistance Accessory—order as separate line item API BP4 Spare removable 4 terminal plug, black How to Order Models are factory ranged. See I/O ranges above left. Ranges and options for each channel must be specified on order Channel 1 input range Channel 2 input range Channel 1 output range Channel 2 output range Model Description Power APD 2067 DuoPak 2 channel AC-DC, Freq.-DC converter/isolator/ transmitter 85-265 VAC, 50/60 Hz or 60-300 VDC APD 2067 D 9-30 VDC or 10-32 VAC Options and Accessories Quick Link api-usa.com/2000 Free Factory I/O Setup! H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H H Made in USA File E145968 85-265 VAC, 60-300 VDC model only

Similar Manuals in the Transmitter Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Vega VEGABAR 82

PDF Manual (@FNZ35Z), Vega VEGABAR 82 Transmitter (12-04-2026)

88 341 62 12-04-2026 view all manuals
Emcee TTU500FA

#5A8F7I: TTU500FA Transmitter Operation & user’s manual

77 783 126 20-04-2026 view all manuals
Load Range Systems T74USB

T74USB (Transmitter ePDF Manual, #MN2US1)

11 459 92 26-08-2026 view all manuals
RKI Instruments 65-2443SS

#HC2A77: 65-2443SS Transmitter Operator's manual

19 250 63 05-06-2026 view all manuals
Electro-Voice CSH-1000

PDF User Guide (@BVE22W), Electro-Voice CSH-1000 Transmitter (22-06-2026)

3 1346 270 22-06-2026 view all manuals
Ashcroft XLDP1

XLDP1 (Transmitter ePDF Guide, #GY37D3)

2 772 116 02-09-2026 view all manuals