1 pdf manual(s) Argus Security SGCP100-IS for free download (Document Types: Quick start manual)

Argus Security SGCP100-IS Quick start manual Thumbnail

Argus Security SGCP100-IS Quick start manual [PDF] (2 pages)

  • Identifier: id-2198005
  • Brand: Argus Security
  • Device: Argus Security SGCP100-IS Security System
  • Type: Quick start manual, PDF
  • Key Aspects: Operational Mode Explanations, Storage and Care Recommendations, Hardware Setup Instructions
  • UPD Date: 04.06.2026
  • Source File: 2089628.pdf
  • Pages: 2
  • Description: Usage and setup manual for the Argus Security SGCP100-IS.
Pages Preview:
  • Argus Security SGCP100-IS Quick start manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
[email protected] L20-SGCP1IS-0001 (vA.4) www.argussecurity.it ARGUS SECURITY S.R.L., Via del Canneto, 14 - 34015 - Muggia (TS) - Italy SGCP100-IS INTRINSICALLY SAFE WIRELESS CALL POINT GENERAL DESCRIPTION The intrinsically safe wireless call point is a wall mounted device that, when activated, initiates an alarm on the fire security system. Its construction makes it suitable for installation in hazardous environment according to ATEX DIRECTIVE 2014/34/EU. Table 1 TECHNICAL SPECIFICATIONS *** Communication range with the wire to wireless translator or wireless expander 200 m (in open space) * Operating frequency 868 MHz Modulation type FSK Operating frequency channels 7 Radiated power 5 dBm (3 mW) Main battery type CR123A (3V & 1.2 Ah) - Duracell Ultra Secondary battery type CR2032А (3V & 250 mAh) - Maxell Approved battery voltage range 2.75V - 3.20V Main battery lifespan 3 years ** Secondary battery lifespan 2 months ** Dimensions 86 mm x 86 mm x 59 mm Weight 186 grams (without batteries) Operating temperature range from –10 °C to +55 °C * Ideal operating range: may vary according to environmental conditions. ** When a low battery condition is indicated, both main and secondary batteries must be changed together. ** If it is assumed that the device is set with a message transmission period of 60 seconds. *** Check latest version of document TDS-SCP1IS-0002 for further data, obtainable from your supplier. Device’s removal holes Insertion hole for the reset key Front operating element Visual LED indicator Manual activation point Wall mounting back box Main battery Secondary battery Tamper spring Link - program switch Picture 1 Picture 2 Picture 3 Picture 4 Picture 5 Reset key PCB battery contact Picture 6 - primary battery, secondary battery, primary battery housing and link - program switch Picture 7 - correct battery insertion DEVICE’S POWER SUPPLY, PROGRAMMING AND LINKING The linking operation will configure the call point onto the wireless system controlled by a Translator interface. The linking method described below does not change and applies for operation with either the wire to wireless translator interface or the Wirelex computer configuration program. 1) Move the link-program switch to position ON (picture 6). 2) Insert the secondary battery into its housing (picture 6). 3) Insert the primary battery into its housing then into the device terminals of the PCB making sure that these remain on the outer part of the intrinsically safe battery contact as indicated in picture 7; the visual LED indicator will switch on accordingly (see “Power up” in table 2 and picture 7). Ensure that the polarity is correct for both batteries!!! 4) When the wire to wireless translator (locally or remotely via Wirelex) is searching for a new device to link to, move the link-program switch to position 1 in order to initiate communication with the translator or the expander module; the visual LED indicator will switch on accordingly (see “Programming and linking to the system” in table 2). If the linking and programming operation fails, check if mistakes were made with the wire to wireless translator or the Wirelex link process, remove the batteries, change over repeatedly the ON / 1 switch a few times in order to discharge the internal capacitor and then start again from point 1 re-performing the linking procedure. Call point status Green LED Red LED Power up Device not linked Link - program switch on “ON” 0.5 second green, then blinking red until power up is completed Programming and linking to the system Blinking until linking and program- ming is completed - Power up Device linked Link - program switch on “1” Blinking until power up is complet- ed - Normal condition - - Alarm activation - 1 second on and 1 second off Main battery fault - 0.5 second on and 10 seconds off Secondary battery fault 0.5 second on and 10 seconds off - Both batteries fault 0.5 second green, 5 seconds off, 0.5 second red Not communicating with the translator or the expander 0.1 second green and red (amber) and 1 second off Table 2 1 2 Intrinsically Safe battery contact PCB Battery positive terminal CALL POINT’S VISUAL LED INDICATOR The wireless call point is equipped with a bi-colour LED (red / green) that provides visual indication for functional conditions and battery levels as indicated in table 2. The indicator is positioned near the lower right corner of the device’s operating element (see picture 2). INTRODUCTION TO THE INTRINSICALLY SAFE FIRE DETECTION DEVICE This wireless manual call point has been certified by Baseefa and has been awarded the ATEX Classification II 1 G ; Ex ia IIC T5 Ga –10˚C ≤ Ta ≤ +55˚C making it suitable for Category 1, 2 or 3 hazardous atmospheres with a maximum ambient temperature up to 55˚C. The product has been assessed and certified for ATEX & IECEx requirements for hazardous applications according to the following standards: IEC 60079-0:2011 / EN 60079-0:2012+A11:2013 IEC 60079-11:2011 / EN 60079-11:2012 IEC 60079-28:2015 / EN 60079-28:2015 It is recommended that installation only be carried out by qualified personnel according to hazardous area safe working practice and in conformity to the terms of the product certification. Note that the Translator Interface to which this device will be linked does not form part of the ATEX/IECEx certified system and must be sited in the safe area which is not subject to hazardous conditions. Baseefa16ATEX0111X IECEx BAS 16.0050X

Similar Manuals in the Security System Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
DSC PowerSeries PC1404

PowerSeries PC1404 (Security System ePDF User Guide, #QCDF7I)

28 1.84 Mb 233 52 10-06-2026 view all manuals
Novus NVR-6316P16-H2

#7XPB79: NVR-6316P16-H2 Security System Operation & user’s manual

72 1440 231 10-07-2026 view all manuals
Loggerflex bun hydro

Data Loggers #2B5YC1

20 521 89 16-05-2026 view all manuals
Union Community VIRDI 3000

Security System #W9ISK4

63 843 144 26-06-2026 view all manuals
Aegis AEGIS 1000

Aegis AEGIS 1000 User Manual (Owner's manual), @31S88Z

73 617 130 24-04-2026 view all manuals
Bosch CP700B

Bosch CP700B User Manual (Installer's reference manual), @5928QM

12 629 126 15-07-2026 view all manuals