Ariston Type C Manuals

8 pdf manual(s) Ariston Type C for free download (Document Types: Installation instructions manual, Installation and servicing instructions, Installation, servicing and operating instructions)

Document Preview & Text Transcription

Installation Instructions Type C Boilers G.C.N: 47-116-16 LEAVE THESE INSTRUCTIONS WITH THE END-USER Country of destination: GB 2 TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 GENERAL INSTRUCTIONS 1.2 OVERALL VIEW 2. INSTALLATION 2.1 REFERENCE STANDARDS 2.2 SITING THE APPLIANCE 2.3 OVERALL DIMENSIONS 2.4 CLEARANCES 2.5 MOUNTING THE APPLIANCE 2.6 ELECTRICAL CONNECTION 2.7 GAS CONNECTION 2.8 WATER CONNECTIONS 2.9 FLUE CONNECTION 2.10 ROOM THERMOSTAT CONNECTION 2.11 ELECTRICAL/SYSTEM DIAGRAMS 2.12 WATER CIRCUIT DIAGRAM 3. COMMISSIONING 3.1 INITIAL PREPARATION 3.2 CONTROL PANEL 3.3 REMOVING THE FRONT PANEL 3.4 INITIAL START UP 3.5 OPERATIONAL ADJUSTMENTS 3.6 COMBUSTION ANALYSIS 3.7 FUME DISCHARGE MONITORING 3.8 BOILER SAFETY SYSTEMS 3.9 DRAINING THE SYSTEM 4. GAS ADJUSTMENTS GAS ADJUSTMENT TABLE 4.1 CHANGING THE TYPE OF GAS 5. MAINTENANCE 6. MISCELLANEOUS 6.1 WIRING DIAGRAM FOR TWO HEATING ZONES 6.2 WIRING DIAGRAM FOR CONNECTION TO AN ARISTON UNVENTED CYLINDER 7. TECHNICAL INFORMATION This manual is an integral and essential part of the product. It should be kept with the appliance so that it can be consulted by the user and our authorised personnel. Please carefully read the instructions and notices about the unit contained in this manual, as they provide important information regarding the safe installation, use and maintenance of the product. For operating instructions please consult the separate Users Manual. Read the instructions and recommendations in these Installation Instructions carefully to ensure proper installation, use and maintenance of the appliance. Keep this manual in a safe place. You may need it for your own reference while our Servicing Centre technicians or your installer may need to consult it in the future. This is a combined appliance for the production of central heating (C.H.) and domestic hot water (D.H.W.). This appliance must be used only for the purpose for which it is designed. The manufacturer declines all liability for damage caused by improper or negligent use. No asbestos or other hazardous materials have been used in the fabrication of this product. Before connecting the appliance, check that the information shown on the data plate and the table in section 7 comply with the electric, water and gas mains of the property.You will find the data plate on the reverse of the control panel. The gas with which this appliance operates is also shown on the label at the bottom of the boiler. Do not install this appliance in a damp environment or close to equipment which spray water or other liquids. Do not place objects on the appliance. Do not allow children or inexperienced persons to use the appliance without supervision. If you smell gas in the room, do not turn on light switches, use the telephone or any other object which might cause sparks. Open doors and windows immediately to ventilate the room. Shut the gas mains tap (at or adjacent to the gas meter) or the valve of the gas cylinder and call your Gas Supplier immediately. If you are going away for a long period of time, remember to shut the mains gas tap or the gas cylinder valve. Always disconnect the appliance either by unplugging it from the mains or turning off the mains switch before cleaning the appliance or carrying out maintenance. In the case of faults or failure, switch off the appliance and turn off the gas tap. Do not tamper with the appliance. For repairs, call your local Authorised Servicing Centre and request the use of original spare parts. For in-guarantee repairs contact MTS (GB) Limited. Check the following at least once a year: 1 - Check the seals for the water connections; replace any faulty seals. 2 - Check the gas seals; replace any faulty gas seals. 3 - Visual check of the entire unit. 4 - Visual check of the combustion process or analysis of combustion by- products (see section 3.6) and cleaning of the burner if needed. 1. GENERAL INFORMATION 3 1.1 GENERAL INSTRUCTIONS

Document Preview & Text Transcription

Installation Instructions Type C Boilers G.C.N: 47-116-14 47-116-15 LEAVE THESE INSTRUCTIONS WITH THE END-USER Country of destination: GB 2 TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 GENERAL INSTRUCTIONS 1.2 OVERALL VIEW 2. INSTALLATION 2.1 REFERENCE STANDARDS 2.2 SITING THE APPLIANCE 2.3 OVERALL DIMENSIONS 2.4 CLEARANCES 2.5 MOUNTING THE APPLIANCE 2.6 ELECTRICAL CONNECTION 2.7 GAS CONNECTION 2.8 WATER CONNECTIONS 2.9 FLUE CONNECTION 2.10 ROOM THERMOSTAT CONNECTION 2.11 ELECTRICAL/SYSTEM DIAGRAMS 2.12 WATER CIRCUIT DIAGRAMS 3. COMMISSIONING 3.1 INITIAL PREPARATION 3.2 CONTROL PANEL 3.3 REMOVING THE FRONT PANEL 3.4 INITIAL START UP 3.5 OPERATIONAL ADJUSTMENTS 3.6 COMBUSTION ANALYSIS 3.7 FUME DISCHARGE MONITORING 3.8 BOILER SAFETY SYSTEMS 3.9 DRAINING THE SYSTEM 4. GAS ADJUSTMENTS GAS ADJUSTMENT TABLE 4.1 CHANGING THE TYPE OF GAS 5. MAINTENANCE 6. MISCELLANEOUS 6.1 WIRING DIAGRAM FOR TWO HEATING ZONES 6.2 WIRING DIAGRAM FOR CONNECTION TO AN ARISTON UNVENTED CYLINDER 7. TECHNICAL INFORMATION This manual is an integral and essential part of the product. It should be kept with the appliance so that it can be consulted by the user and our authorised personnel. Please carefully read the instructions and notices about the unit contained in this manual, as they provide important information regarding the safe installation, use and maintenance of the product. For operating instructions please consult the separate User’s Manual. Read the instructions and recommendations in these Installation Instructions carefully to ensure proper installation, use and maintenance of the appliance. Keep this manual in a safe place. You may need it for your own reference while our Servicing Centre technicians or your installer may need to consult it in the future. This is a combined appliance for the production of central heating (C.H.) and domestic hot water (D.H.W.). This appliance must be used only for the purpose for which it is designed. The manufacturer declines all liability for damage caused by improper or negligent use. No asbestos or other hazardous materials have been used in the fabrication of this product. Before connecting the appliance, check that the information shown on the data plate and the table on pages 4-5 comply with the electric, water and gas mains of the property.You will find the data plate on the reverse of the control panel. The gas with which this appliance operates is also shown on the label at the bottom of the boiler. Do not install this appliance in a damp environment or close to equipment which spray water or other liquids. Do not place objects on the appliance. Do not allow children or inexperienced persons to use the appliance without supervision. If you smell gas in the room, do not turn on light switches, use the telephone or any other object which might cause sparks. Open doors and windows immediately to ventilate the room. Shut the gas mains tap (on the gas meter) or the valve of the gas cylinder and call your Gas Supplier immediately. If you are going away for a long period of time, remember to shut the mains gas tap or the gas cylinder valve. Always disconnect the appliance either by unplugging it from the mains or turning off the mains switch before cleaning the appliance or carrying out maintenance. In the case of faults or failure, switch off the appliance and turn off the gas tap. Do not tamper with the appliance. For repairs, call your local Authorised Servicing Centre and request the use of original spare parts. For in-guarantee repairs contact MTS (GB) Limited. Check the following at least once a year: 1 - Check the seals for the water connections; replacement of any faulty seals. 2 - Check the gas seals; replacement of any faulty gas seals. 3 - Visual check of the entire unit. 4 - Visual check of the combustion process or analysis of combustion by- products (see section 3.6) and cleaning of the burner if needed. 1. GENERAL INFORMATION 3 1.1 GENERAL INSTRUCTIONS CO034A 4 5 - If called for by point. 3, dismantling and cleaning of the combustion chamber. 6 - If called for by point. 4, dismantling and cleaning of the burner jets. 7 - Visual check of the primary heat exchanger: - check for overheating in the blade assembly; - clean the exhaust fan if needed. 8 - Adjustment of the flow rate of the gas: flow rate for lighting, partial load and full load. 9 - Check of the heating safety systems: - safety device for maximum temperature; - safety device for maximum pressure. 10- Check of the gas safety systems: - safety device for lack of gas or flame ionisation (detection electrode); - safety device for gas cock. 11- Check of the electrical connection (make sure it complies with the instructions in the manual). 12- Check of domestic hot water production efficiency (flow rate and temperature) 13- General check of the combustion by-products of the discharge/ventilation system. 14- Check of the general performance of the unit. LEGEND: 1. Flue connector 2. Air intake for twin pipe flue systems 3. Fan 4. Combustion chamber hood 5. Main heat exchanger 6. Safety thermostat 7. Combustion chamber 8. Combustion chamber insulation panel 9. Burner 10. Detection electrode 11. Ignition electrodes 12. Motorised diverter valve 13. Main circuit temperature probe 14. Main circuit flow switch 15. Domestic hot water temperature probe 16. Gas valve 17. Spark generator 18. Domestic hot water flow switch 19. Domestic cold water inlet filter 20. Secondary heat exchanger 21. Circulation pump with automatic air release valve 22. Safety valve (3 bar) 23. Expansion vessel 24. Air pressure switch 25. Combustion analysis intakes 1.2 OVERALL VIEW FIG. 1.0 IN013A