Arjohuntleigh Aura Manuals
1 pdf manual(s) Arjohuntleigh Aura for free download (Document Types: Quick reference manual)
Arjohuntleigh Aura Quick reference manual [PDF] (2 pages)
- Identifier: id-2189038
- Brand: Arjohuntleigh
- Device: Aura Medical Equipment
- Type: PDF
- Key Aspects: Unpacking and Inspection Guidelines, Basic Configuration Guidelines, Technical Support and Resource Links
- UPD Date: 05.05.2026
- Source File: 2098596.pdf
- Pages: 2
- Description: Professional operation guide for the Arjohuntleigh Aura.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Connect the pump to the mains power supply using the supplied cable. Set the Run/Standby switch (on the side of the pump) to the Run ( | ) position. The Run/Standby indicator is illuminated when the pump is running. In the event of mains failure, the Power Fail alarm indicator will start flashing and an audible alarm will sound. The pitch of the alarm will increase in time. If the power supply is returned the audible alarm will stop, but the alarm light will remain illuminated until the system is reset using the Run/Standby switch. The Low Pressure indicator will flash whenever the pump detects low pressure in the cushion. An audible alarm will sound. The pitch of the alarm will increase at 60 second intervals. The indicator will extinguish once normal pressure is reached. Check the tubeset is connected properly. Comfort Control - The seat cushion cell pressure can be manually adjusted for patient comfort using the Pressure Control. Note: An internal battery will power an audible and visual alarm if the power supply is interrupted prior to switching off. For example, if the mains lead is removed before switching to Standby mode. The pump alarm can be reset by switching the pump to Standby and back to Run again using the Run/ Standby switch on the side panel. This Quick Reference Guide has been produced to assist Healthcare Professionals and other users with only the functional aspects of the system. This guide does not replace the general safety warnings, cautions and recommendations provided in the product Instructions for Use, part number 500935EN. Refer to the product Instructions for Use before using this product. Caution: Active therapy (alternating) cushions may be unsuitable for patients with poor sitting posture or pelvic deformity; advice from a seating specialist should be sought. Contraindication: Do not use the system for patients with unstable spinal fractures. Caution: If patients have other unstable fractures, or conditions which may be complicated by a soft or moving surface, advice should be sought from an appropriate clinician before use. Indications: • The Aura cushion is designed for patients weighing up to 120 kg (264 lb). • The Aura systems are indicated for the prevention and/or management of all categories 1 of pressure ulcer, when combined with an individualised, comprehensive pressure ulcer protocol. 1. NPUAP/EPUAP International Pressure Ulcer Guideline, 2014. Aura 500937EN_03 · 05/2019 QUICK REFERENCE GUIDE Aura