Key Aspects: Step-by-Step Assembly Procedures, Model Variations and Compatibility, Error Code Explanations
Updated: 23.05.2026
Source File: 1885830.pdf
Pages: 9
Description: Owner’s manual for the ASI EZ FILL.
Document Preview & Text Transcription
05 September 2018
EZ FILL™ FAUCET
AUTOMATIC
DECK MOUNTED FAUCET
INSTALLATION AND MAINTENANCE GUIDE
05 September 2018
05 September 2018
2
1
Unit Install Date
Unit Location in Facility
Unit S/N (From Label)
Supplied By
Original PO No.
ASI Order No.
TABLE OF CONTENTS
PRE-INSTALLATION INFORMATION
Important: All plumbing is to be installed in accordance with applicable codes and
regulations.
CheCk Contents
Separate all parts from the packaging and check each part with the “Pack contents” section.
Pay attention to the different models variations.
Make sure all parts are accounted for before discarding any packaging material.
If any parts are missing, do not attempt to install your electronic faucet until you obtain the
missing parts.
Warnings
Do not install facing a mirror or any other electronic system operated by an infrared sensor.
To prevent reflection problems, it is recommended to keep a minimum distance
of 1.50 meters between the faucet and any other objects.
PreParation for installation
Flush water supply lines thoroughly before installing the faucet. Do not allow dirt, Teflon tape
or metal particles to enter the faucet.
Shut off water supply.
Installations in Australia and New Zealand must comply with the requirements of
AS/NZS 3500.
RECOMMENDED HOLE SIZE
2
PRE-INSTALLATION INFORMATION
3
PACK CONTENTS
4
TECHNICAL DATA
5-7
INSTALLATION
8-9
SETTINGS ADjUSTMENT
10
BATTERY REPLACEMENT INSTRUCTIONS
11
SPARE PARTS LIST
11
MAINTENANCE
12
WARRANTY
13
TROUBLESHOOTING
05 September 2018
05 September 2018
3
4
PACK CONTENTS
EZFILL™ FAUCET
Familiarize yourself with the part names and confirm that the parts are included.
Batteries not included
B VERSION
E VERSION
BATTERy BOx FOR
1.5V BATTERIES x 6
9V TRANSFORMER
1 x FAUCET AND ATTACHMENTS
1 x FILTER
1 x ALLEN KEY
TECHNICAL DATA
EZFILL™ FAUCET (battery powered) - 235100
EZFILL™ FAUCET (transformer powered) - 235200
Power supply:
6 x 1.5V AA batteries or 9V transformer
Recommended water
pressure:
8.0-0.5 bar (116-7 PSI)
With water pressure of more than 8 bars,
use a pressure reducing valve for reduction.
Preset sensor range:
200mm / 7.87” (customizable with optional remote control)
Minimum sensor range:
35mm / 1.38”
Maximum sensor range:
300mm / 11.81”
Security time:
90 seconds (can be reduced with optional remote control)
Hot water temperature:
Max 70˚C
05 September 2018
05 September 2018
5
6
INSTALLATION
STEP 1 – PREPARATION FOR MOUNTING THE FAUCET
1
Shut off the water supply.
2
Remove the hexagonal nut, the disk
and the gasket. Do not remove the
O-ring from the base of the faucet.
NUT
DISC
GASKET
O-RING
STEP 2 – INSTALLING THE FAUCET
1
Place the faucet with O-ring into the
hole in deck or lavatory. Make sure the
O-ring is located between the deck or
lavatory and the bottom of the faucet.
O-RING
2
Slide the gasket, disk and hexagonal
nut over the flexible hose and secure
the faucet into place.
NUT
DISC
GASKET
NUT
DISC
GASKET
O-RING
O-RING
INSTALLATION
STEP 3 – CONNECTING THE WATER SUPPLY
1
Connect the flexible pipe to the water
supply.
For models with temperature control
connect the red flexible pipe to the hot
water supply and the blue flexible pipe
to the cold water supply.
MAKE SURE THAT THE FILTER(S) IS/ARE INSTALLED BETWEEN THE FLExIBLE PIPE AND THE
SHUT OFF VALVE (ANGLE VALVE) (NOT SUPPLIED).
2
Turn on the central water supply and
the shut-off valves (angle valves) and
check for leaks.
Key Aspects: Risk Mitigation and Accident Prevention, Cleaning and Sanitization Methods, Emergency Shutdown Procedures
Updated: 21.05.2026
Source File: 1885829.pdf
Pages: 12
Description: Instruction and reference manual for the ASI EZ FILL.
Document Preview & Text Transcription
1311070623 Rev G
EZFILL™ KIT*
EZFILL™ TOP FILL MULTIFEED KIT
WITH 1.6 GAL. (6L) CONTAINER
INSTALLATION AND MAINTENANCE GUIDE
Model 0390
2019
Space Provided For Owner Notes
* EZFILL™ KIT pictured with optional mounting bracket (0390-BR). See page 6
1311070623 Rev G
2019
1311070623 Rev G
TABLE OF CONTENTS
3
PRE-INSTALLATION INFORMATION
4
PACK CONTENTS
5-6
TECHNICAL DATA
7
INSTALLATION
8
FILLING THE SOAP TANK
9
MAINTENANCE
9
TROUBLESHOOTING
9
SPARE PARTS LIST
10
WARRANTY
2
2019
1311070623 Rev G
3
PRE-INSTALLATION INFORMATION
CHECK CONTENTS
Separate all parts from the packaging and check each part with the
PACK CONTENTS section.
Make sure all parts are received and separated before discarding any
packaging material.
If any parts are missing, do not attempt to install the system until you
obtain the missing parts.
IMPORTANT
Ensure there is adequate space and clearance under the vanity to
accommodate the tank in the desired location before drilling the hole
in the counter top.
Ensure there is adequate space to place the Tank and Support Bracket
within reach of the Fill Hose from the Top Fill Port.
2019
Key Aspects: Storage and Care Recommendations, Basic Configuration Guidelines, Hardware Setup Instructions
Updated: 29.07.2026
Source File: 1885831.pdf
Pages: 4
Description: Practical user guide for the ASI EZ FILL.
Document Preview & Text Transcription
Foam Soap Dispenser Troubleshooting and Maintenance
Nozzle
Sensor
Part number: 08002337
Compressor
Part number: 07222010
Pump
Part number: 07222028
AUX connectors
Outlet pipe
Inlet pipe
2
Illustration
Solution
Cause
Investigation
Indication
O-RING VISIBLE –
NOT CONNECTED PROPERLY
ONLY THE GROOVES ARE VISIBLE –
CONNECTED PROPERLY
The connector should be inserted
fully until white o-ring is not visible.
Remove the o-ring if necessary
AUX connector not
fully inserted
Continuous discharge from
the nozzle
False activation:
Foam dispensing
Min 300 mm.
Bottom of the washbasin
Eliminate any cause of reflection and
if necessary use appropriate remote
control PN 07100005 to shorten
detection range.
Reflection issue from
basin or other object
Random discharge from the
nozzle
Replace the Pump: Pump
assembly for wall and deck-mounted
dispenser PN 07222028;
Multifeed Pump assembly for wall and
deck-mounted dispenser
PN 07222034.
Rinse warm water through the pipe
and the body of the soap dispenser all
the way to the nozzle.
Soap discharging from
pump housing.
Fill with soap with correct viscosity
(up to 100 cPs) and prime pipes using
the fill button on remote control.
Soap tank is empty.
Pump and compressor are
making a sound when sensor
is activated
Foam not
dispensing
Press
FILL
Button
Prime the soap dispenser by pressing
the fill button on the remote or by
pressing the refill button located at
the bottom of the pump, until foam
exits the nozzle.
Soap dispenser has
not been primed
Replace the Pump: Pump
assembly for wall and deck-mounted
dispenser PN 07222028;
Multifeed Pump assembly for wall and
deck-mounted dispenser
PN 07222034.
Damaged pump
(discharge from
housing)
Run warm water through pipe, pump,
and body all the way to the nozzle.
Replace with soap of correct viscosity.
NOTE: Using the soap dispenser
with high viscosity soap may cause
permanent damage to the pump and
shorten the lifecycle.
Debris or dried soap
in the pipe or tank
Soap Viscosity
(up to 100 cPs)
High viscosity soap
(>100 cPs)
Unbend or straighten pipes.
Bent pipes
3
Illustration
Solution
Cause
Investigation
Indication
Ensure that the tip of the inlet
pipe is fully immersed in the soap.
For earlier models check that the
pipe has not been pushed so far
that the tip has risen above soap
level. The new models have an
additional sleeve for the pipes
preventing this from occuring.
Tip of inlet pipe is not
immersed in soap
Pump and compressor are making
a sound when sensor is activated
Multifeed units only
Foam not
dispensing
Check that all pipes are connected
firmly to the pump. If necessary
remove pipe, cut 7 mm and
replace firmly.
6mm pipe connecting
pump to dispenser outlet
has come loose
8 mm pipe connecting
pump to tank has come
loose
Replace the Pump: Pump
assembly for wall and deck-
mounted dispenser PN 07222028;
Multifeed Pump assembly for wall
and deck-mounted dispenser PN
07222034
Damaged pump
Pump is making a sound when
sensor is activated, but the
compressor is not.
O-RING VISIBLE –
NOT CONNECTED PROPERLY
ONLY THE GROOVES ARE VISIBLE –
CONNECTED PROPERLY
Insert fully, remove the O ring if
necessary
AUX connector not fully
inserted
Compressor is making a sound
when sensor is activated, but the
pump is not.
Replace the Pump: Pump
assembly for wall and deck-
mounted dispenser PN 07222028;
Multifeed Pump assembly for wall
and deck-mounted dispenser PN
07222034
Damaged Pump
O-RING VISIBLE –
NOT CONNECTED PROPERLY
ONLY THE GROOVES ARE VISIBLE –
CONNECTED PROPERLY
The connector should be inserted
fully until the white o-ring is
not visible. Remove the o-ring if
necessary
AUX connector not fully
inserted
Sensor is
blinking when
hand is placed
in front
Pump is not
making sound
when the sensor
is activated
Foam not
dispensing
Press
Replace the Pump: Pump
assembly for wall and deck-
mounted dispenser PN 07222028;
Multifeed Pump assembly for wall
and deck-mounted dispenser PN
07222034.
Rinse warm water through the
pipe and the body of the soap
dispenserall the way to the
nozzle.
Refill button on pump
does not activate the
pump.
Damaged pump
(discharge from
housing).
Run warm water through pipe,
pump, and body all the way to
the nozzle. Replace with soap of
correct viscosity. NOTE: Using the
soap dispenser with high viscosity
soap may cause permanent
damage to the pump and shorten
the lifecycle.
Debris or dried soap in
the tank or tubing
4
Illustration
Solution
Cause
Investigation
Indication
Refill
button
Transformer: Check operation
with functioning transformer.
Where necessary replace with
appropriate transformer. For part
numbers see spare parts list.
Refill button on pump
does not activate the
pump.
Sensor is not
blinking when
hand is placed
in front
Pump is not
making sound
when the sensor
is activated
Foam not
dispensing
Min 300 mm.
Bottom of the washbasin
Eliminate any cause of reflection
and use appropriate remote
control to shorten detection
range.
Remote Control ref. number:
07100005
Reflection issue from
basin or other object
Replace
sensor
If the above two solutions have
not resolved this issue replace
with appropriate sensor. For part
numbers see spare parts list.
Sensor part number: 08002337
Damaged sensor
1. Increase the air to soap ratio.
Liquid rather than foam
is being dispensed out
of the nozzle
Foam not dispensing
2. Verify that the filter is clean.
3. Replace compressor (supplied
with pump). For part numbers see
spare parts list.
Use remote to decrease soap
volume by pressing the "- Soap"
key.
Foam dosage is too large
Foam is dispensing
Use remote to increase soap
volume by pressing the "+ Soap"
key.
Foam dosage is too small
Use remote to decrease the
amount of air in the foam by
pressing the "- Air" Key.
Foam is too dense
Use remote to increase the
amount of air in the foam by
pressing the " + Air" key.
Foam is too liquefied
Owner’s manual for the Philips HTR5000/01 Home Theater System. It contains information on installation procedures, installation support, backup procedures.