ASI EZ FILL Manuals

3 pdf manual(s) ASI EZ FILL for free download (Document Types: Installation and maintenance manual, Troubleshooting and maintenance manual)

Available Documents for EZ FILL:

ASI EZ FILL Installation and maintenance manual Main Page Preview

Installation and maintenance manual [PDF] (9 pages)

  • Brand: ASI
  • Model: EZ FILL
  • Format: PDF
  • Key Aspects: Step-by-Step Assembly Procedures, Model Variations and Compatibility, Error Code Explanations
  • Updated: 23.05.2026
  • Source File: 1885830.pdf
  • Pages: 9
  • Description: Owner’s manual for the ASI EZ FILL.

Document Preview & Text Transcription

05 September 2018 EZ FILL™ FAUCET AUTOMATIC DECK MOUNTED FAUCET INSTALLATION AND MAINTENANCE GUIDE 05 September 2018 05 September 2018 2 1 Unit Install Date Unit Location in Facility Unit S/N (From Label) Supplied By Original PO No. ASI Order No. TABLE OF CONTENTS PRE-INSTALLATION INFORMATION Important: All plumbing is to be installed in accordance with applicable codes and regulations. CheCk Contents Separate all parts from the packaging and check each part with the “Pack contents” section. Pay attention to the different models variations. Make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not attempt to install your electronic faucet until you obtain the missing parts. Warnings Do not install facing a mirror or any other electronic system operated by an infrared sensor. To prevent reflection problems, it is recommended to keep a minimum distance of 1.50 meters between the faucet and any other objects. PreParation for installation Flush water supply lines thoroughly before installing the faucet. Do not allow dirt, Teflon tape or metal particles to enter the faucet. Shut off water supply. Installations in Australia and New Zealand must comply with the requirements of AS/NZS 3500. RECOMMENDED HOLE SIZE 2 PRE-INSTALLATION INFORMATION 3 PACK CONTENTS 4 TECHNICAL DATA 5-7 INSTALLATION 8-9 SETTINGS ADjUSTMENT 10 BATTERY REPLACEMENT INSTRUCTIONS 11 SPARE PARTS LIST 11 MAINTENANCE 12 WARRANTY 13 TROUBLESHOOTING 05 September 2018 05 September 2018 3 4 PACK CONTENTS EZFILL™ FAUCET Familiarize yourself with the part names and confirm that the parts are included. Batteries not included B VERSION E VERSION BATTERy BOx FOR 1.5V BATTERIES x 6 9V TRANSFORMER 1 x FAUCET AND ATTACHMENTS 1 x FILTER 1 x ALLEN KEY TECHNICAL DATA EZFILL™ FAUCET (battery powered) - 235100 EZFILL™ FAUCET (transformer powered) - 235200 Power supply: 6 x 1.5V AA batteries or 9V transformer Recommended water pressure: 8.0-0.5 bar (116-7 PSI) With water pressure of more than 8 bars, use a pressure reducing valve for reduction. Preset sensor range: 200mm / 7.87” (customizable with optional remote control) Minimum sensor range: 35mm / 1.38” Maximum sensor range: 300mm / 11.81” Security time: 90 seconds (can be reduced with optional remote control) Hot water temperature: Max 70˚C 05 September 2018 05 September 2018 5 6 INSTALLATION STEP 1 – PREPARATION FOR MOUNTING THE FAUCET 1 Shut off the water supply. 2 Remove the hexagonal nut, the disk and the gasket. Do not remove the O-ring from the base of the faucet. NUT DISC GASKET O-RING STEP 2 – INSTALLING THE FAUCET 1 Place the faucet with O-ring into the hole in deck or lavatory. Make sure the O-ring is located between the deck or lavatory and the bottom of the faucet. O-RING 2 Slide the gasket, disk and hexagonal nut over the flexible hose and secure the faucet into place. NUT DISC GASKET NUT DISC GASKET O-RING O-RING INSTALLATION STEP 3 – CONNECTING THE WATER SUPPLY 1 Connect the flexible pipe to the water supply. For models with temperature control connect the red flexible pipe to the hot water supply and the blue flexible pipe to the cold water supply. MAKE SURE THAT THE FILTER(S) IS/ARE INSTALLED BETWEEN THE FLExIBLE PIPE AND THE SHUT OFF VALVE (ANGLE VALVE) (NOT SUPPLIED). 2 Turn on the central water supply and the shut-off valves (angle valves) and check for leaks.
ASI EZ FILL Installation and maintenance manual Main Page Preview

Installation and maintenance manual [PDF] (12 pages)

  • Brand: ASI
  • Model: EZ FILL
  • Format: PDF
  • Key Aspects: Risk Mitigation and Accident Prevention, Cleaning and Sanitization Methods, Emergency Shutdown Procedures
  • Updated: 21.05.2026
  • Source File: 1885829.pdf
  • Pages: 12
  • Description: Instruction and reference manual for the ASI EZ FILL.

Document Preview & Text Transcription

1311070623 Rev G EZFILL™ KIT* EZFILL™ TOP FILL MULTIFEED KIT WITH 1.6 GAL. (6L) CONTAINER INSTALLATION AND MAINTENANCE GUIDE Model 0390 2019 Space Provided For Owner Notes * EZFILL™ KIT pictured with optional mounting bracket (0390-BR). See page 6 1311070623 Rev G 2019 1311070623 Rev G TABLE OF CONTENTS 3 PRE-INSTALLATION INFORMATION 4 PACK CONTENTS 5-6 TECHNICAL DATA 7 INSTALLATION 8 FILLING THE SOAP TANK 9 MAINTENANCE 9 TROUBLESHOOTING 9 SPARE PARTS LIST 10 WARRANTY 2 2019 1311070623 Rev G 3 PRE-INSTALLATION INFORMATION CHECK CONTENTS Separate all parts from the packaging and check each part with the PACK CONTENTS section. Make sure all parts are received and separated before discarding any packaging material. If any parts are missing, do not attempt to install the system until you obtain the missing parts. IMPORTANT Ensure there is adequate space and clearance under the vanity to accommodate the tank in the desired location before drilling the hole in the counter top. Ensure there is adequate space to place the Tank and Support Bracket within reach of the Fill Hose from the Top Fill Port. 2019
ASI EZ FILL Troubleshooting and maintenance manual Main Page Preview

Troubleshooting and maintenance manual [PDF] (4 pages)

  • Brand: ASI
  • Model: EZ FILL
  • Format: PDF
  • Key Aspects: Storage and Care Recommendations, Basic Configuration Guidelines, Hardware Setup Instructions
  • Updated: 29.07.2026
  • Source File: 1885831.pdf
  • Pages: 4
  • Description: Practical user guide for the ASI EZ FILL.

Document Preview & Text Transcription

Foam Soap Dispenser Troubleshooting and Maintenance Nozzle Sensor Part number: 08002337 Compressor Part number: 07222010 Pump Part number: 07222028 AUX connectors Outlet pipe Inlet pipe 2 Illustration Solution Cause Investigation Indication O-RING VISIBLE – NOT CONNECTED PROPERLY ONLY THE GROOVES ARE VISIBLE – CONNECTED PROPERLY The connector should be inserted fully until white o-ring is not visible. Remove the o-ring if necessary AUX connector not fully inserted Continuous discharge from the nozzle False activation: Foam dispensing Min 300 mm. Bottom of the washbasin Eliminate any cause of reflection and if necessary use appropriate remote control PN 07100005 to shorten detection range. Reflection issue from basin or other object Random discharge from the nozzle Replace the Pump: Pump assembly for wall and deck-mounted dispenser PN 07222028; Multifeed Pump assembly for wall and deck-mounted dispenser PN 07222034. Rinse warm water through the pipe and the body of the soap dispenser all the way to the nozzle. Soap discharging from pump housing. Fill with soap with correct viscosity (up to 100 cPs) and prime pipes using the fill button on remote control. Soap tank is empty. Pump and compressor are making a sound when sensor is activated Foam not dispensing Press FILL Button Prime the soap dispenser by pressing the fill button on the remote or by pressing the refill button located at the bottom of the pump, until foam exits the nozzle. Soap dispenser has not been primed Replace the Pump: Pump assembly for wall and deck-mounted dispenser PN 07222028; Multifeed Pump assembly for wall and deck-mounted dispenser PN 07222034. Damaged pump (discharge from housing) Run warm water through pipe, pump, and body all the way to the nozzle. Replace with soap of correct viscosity. NOTE: Using the soap dispenser with high viscosity soap may cause permanent damage to the pump and shorten the lifecycle. Debris or dried soap in the pipe or tank Soap Viscosity (up to 100 cPs) High viscosity soap (>100 cPs) Unbend or straighten pipes. Bent pipes 3 Illustration Solution Cause Investigation Indication Ensure that the tip of the inlet pipe is fully immersed in the soap. For earlier models check that the pipe has not been pushed so far that the tip has risen above soap level. The new models have an additional sleeve for the pipes preventing this from occuring. Tip of inlet pipe is not immersed in soap Pump and compressor are making a sound when sensor is activated Multifeed units only Foam not dispensing Check that all pipes are connected firmly to the pump. If necessary remove pipe, cut 7 mm and replace firmly. 6mm pipe connecting pump to dispenser outlet has come loose 8 mm pipe connecting pump to tank has come loose Replace the Pump: Pump assembly for wall and deck- mounted dispenser PN 07222028; Multifeed Pump assembly for wall and deck-mounted dispenser PN 07222034 Damaged pump Pump is making a sound when sensor is activated, but the compressor is not. O-RING VISIBLE – NOT CONNECTED PROPERLY ONLY THE GROOVES ARE VISIBLE – CONNECTED PROPERLY Insert fully, remove the O ring if necessary AUX connector not fully inserted Compressor is making a sound when sensor is activated, but the pump is not. Replace the Pump: Pump assembly for wall and deck- mounted dispenser PN 07222028; Multifeed Pump assembly for wall and deck-mounted dispenser PN 07222034 Damaged Pump O-RING VISIBLE – NOT CONNECTED PROPERLY ONLY THE GROOVES ARE VISIBLE – CONNECTED PROPERLY The connector should be inserted fully until the white o-ring is not visible. Remove the o-ring if necessary AUX connector not fully inserted Sensor is blinking when hand is placed in front Pump is not making sound when the sensor is activated Foam not dispensing Press Replace the Pump: Pump assembly for wall and deck- mounted dispenser PN 07222028; Multifeed Pump assembly for wall and deck-mounted dispenser PN 07222034. Rinse warm water through the pipe and the body of the soap dispenserall the way to the nozzle. Refill button on pump does not activate the pump. Damaged pump (discharge from housing). Run warm water through pipe, pump, and body all the way to the nozzle. Replace with soap of correct viscosity. NOTE: Using the soap dispenser with high viscosity soap may cause permanent damage to the pump and shorten the lifecycle. Debris or dried soap in the tank or tubing 4 Illustration Solution Cause Investigation Indication Refill button Transformer: Check operation with functioning transformer. Where necessary replace with appropriate transformer. For part numbers see spare parts list. Refill button on pump does not activate the pump. Sensor is not blinking when hand is placed in front Pump is not making sound when the sensor is activated Foam not dispensing Min 300 mm. Bottom of the washbasin Eliminate any cause of reflection and use appropriate remote control to shorten detection range. Remote Control ref. number: 07100005 Reflection issue from basin or other object Replace sensor If the above two solutions have not resolved this issue replace with appropriate sensor. For part numbers see spare parts list. Sensor part number: 08002337 Damaged sensor 1. Increase the air to soap ratio. Liquid rather than foam is being dispensed out of the nozzle Foam not dispensing 2. Verify that the filter is clean. 3. Replace compressor (supplied with pump). For part numbers see spare parts list. Use remote to decrease soap volume by pressing the "- Soap" key. Foam dosage is too large Foam is dispensing Use remote to increase soap volume by pressing the "+ Soap" key. Foam dosage is too small Use remote to decrease the amount of air in the foam by pressing the "- Air" Key. Foam is too dense Use remote to increase the amount of air in the foam by pressing the " + Air" key. Foam is too liquefied

EZ FILL: Related Instructions

Manuals from Other Manufacturers