Autocall TrueAlert ES Manuals

1 pdf manual(s) Autocall TrueAlert ES for free download (Document Types: Installation instructions manual)

Autocall TrueAlert ES Installation instructions manual Thumbnail

Autocall TrueAlert ES Installation instructions manual [PDF] (6 pages)

  • Identifier: id-1750730
  • Brand: Autocall
  • Device: Autocall TrueAlert ES Racks & Stands
  • Type: Installation instructions manual, PDF
  • Key Aspects: Detailed Installation Instructions, Cleaning and Sanitization Methods, Pre-Installation Safety Requirements
  • UPD Date: 29.07.2026
  • Source File: 1789551.pdf
  • Pages: 6
  • Description: Official product manual for the Autocall TrueAlert ES.
Pages Preview:
  • Autocall TrueAlert ES Installation instructions manual preview - page 2
  • Autocall TrueAlert ES Installation instructions manual preview - page 3
  • Autocall TrueAlert ES Installation instructions manual preview - page 4
  • Autocall TrueAlert ES Installation instructions manual preview - page 5
  • Autocall TrueAlert ES Installation instructions manual preview - page 6
Document Preview & Text Transcription (Main Page)
Click to expand and read text
579-1227AC Rev D TrueAlert ES Addressable Ceiling Mount Visual Indoor Notification Appliances Installation Instructions *05791227ACD* Cautions, warnings, and regulatory information Important: When the notification appliance emits light or sound, it indicates the possibility of an emergency situation that requires immediate atten- tion of all occupants. SAFETY: Always install, maintain, and test notification appliances within their specifications. Failure to follow all safety precautions and instructions may result in loss of life and property due to non-functioning notification appliances. Some notification appliances use high voltage. To avoid electrical hazards and avoid damage to appliances, make sure that the electrical power for the Notification Appliance Circuit is disconnected at the control panel before installing, repairing, or internally adjusting any notification appliances. Even with electrical power removed, some notification appliances (such as visible strobes) store a high voltage charge. The high voltage can cause injury resulting in death from electrical shock. DO NOT TOUCH EXPOSED CIRCUITRY. LOCATION REFERENCE: Location and quantity of appliances required must conform to the applicable local standards and guidelines (the National Fire Alarm and Signaling Code (NFPA 72); ULC Standard CAN/ULC-S524, Installation of Fire Alarm Systems; the appropriate model building codes, etc.) and specific requirements of the Local Authority Having Jurisdiction (AHJ). These notification appliances are not intended for installation within hazardous locations as defined by the National Electrical Code (NEC) or NFPA. UL Listed TrueAlert ES indoor product identification reference Type Models Cover colors Operation TrueAlert ES Ceiling Mount Visible Only (VO) Appliance Components: A49VO-APPLC A49VO-APPLC-BA A49VOH-APPLC A49VOH-APPLC-BA A49VOH-APPLCA A49VOH-APPLCA-BA A49VOH-APPLCB A49VOH-APPLCB-BA Accessories: 49VO-APCS Covers: A49VOC-CRALT A49VOC-CRBF A49VOC-CRFEU A49VOC-CRF A49VOC-CRS A49VOC-CWALT A49VOC-CWBF A49VOC-CWFEU A49VOC-CWF A49VOC-CWS A49VOC-CK A49VOC-CRBAF A49VOC-CRBCF A49VOC-CWBAF A49VOC-CWBCF A49VOC-CRBAA A49VOC-CWBAA • Red • White • Black These appliances provide a visible only (VO) warning of an alarm condition when activated from the control panel of a compatible UL/ ULC Listed, Autocall Fire Alarm System. Consult Autocall Fire Alarm panel documentation for compatibility information. VO models ‘49VOH’ have Hi intensity strobes; models ‘49VO’ have standard range strobes. Kit Contents Appliance x1, with 8-32 1 in. mounting screws x 2. Not Included Order a cover separately for each appliance. Electrical box, 1.5 in. (3.81 cm) minimum depth required, 4 in. (10.16 cm) square or single gang with an adapter plate. 49VO-APCS adapter plate for use with the single gang electrical box, with 4-40 screws x2, and 6-32 screws x 2. Note: For information about appliance testing, see TrueAlert ES Addressable Appliances Troubleshooting Guide (579-1049AC). Mounting instructions 1. Select the correct location and install the electrical box using screws suitable for the mounting surface. 2. Connect the building wires to the terminal block on the rear of the appliance. See Wiring instructions. 3. Use the hardware provided to secure the appliance to the electrical box. Installing the appliance using a single gang electrical box requires a 49VO-APCS adapter plate. You can mount the adapter plate in two orientations, see Wiring instructions. 4. Set the appliance settings. See Setting the address DIP switch. 5. Attach the cover to the appliance.

Similar Manuals in the Racks & Stands Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Humminbird SCBK1

Humminbird SCBK1 User Guide (Manual ), @Y9347O

4 1314 290 01-09-2026 view all manuals
PLD MOBO-CX50

PLD MOBO-CX50 Manual (Quick start manual), @LPT5HT

8 774 132 11-05-2026 view all manuals
Kenko Skymemo RS

Skymemo RS (Racks & Stands ePDF Guide, #Q4V6LQ)

10 1466 338 02-07-2026 view all manuals
Rehadapt Floorstand PentaFloat Eco

#1723KJ: Floorstand PentaFloat Eco Racks & Stands Operation & user’s manual

4 795 167 03-07-2026 view all manuals
Menabo JUZA

JUZA Fitting instructions manual - A1N2DJ

8 342 76 20-04-2026 view all manuals
Polycom Polycom VVX 500

Polycom IP Phone Quick cloud quick manual (File: PDF, 21-04-2026)

2 42 9 21-04-2026 view all manuals