AUTOFLAME Mk8 MM Manuals

6 pdf manual(s) AUTOFLAME Mk8 MM for free download (Document Types: Installation & commissioning manual, End user manual, Installation and commissioning manual)

Document Preview & Text Transcription

Mini Mk8 M.M. Installation & Commissioning Guide Mini Mk8 MM Installation and Commissioning Guide Issued by: AUTOFLAME ENGINEERING LTD Unit 1-2, Concorde Business Centre Airport Industrial Estate, Wireless Road Biggin Hill, Kent TN16 3YN Tel: +44 (0)845 872 2000 Fax: +44 (0)845 872 2010 Email: [email protected] Website: http://www.autoflame.com/ Registered Holder: Company: Department: This manual and all the information contained herein is copyright of Autoflame Engineering Ltd. It may not be copied in the whole or part without the consent of the Managing Director. Autoflame Engineering Ltd’s policy is one of continuous improvement in both design and manufacture. We therefore reserve the right to amend specifications and/or data without prior notice. All details contained in this manual are correct at the time of going to print.
AUTOFLAME Mk8 MM End user manual Main Page Preview

End user manual [PDF] (72 pages)

  • Updated: 05.04.2026

Document Preview & Text Transcription

Mk8 MM End User Guide Mk8 MM End User Guide Issued by: AUTOFLAME ENGINEERING LTD Unit 1-2, Concorde Business Centre Airport Industrial Estate, Wireless Road Biggin Hill, Kent TN16 3YN Tel: +44 (0)845 872 2000 Fax: +44 (0)845 872 2010 Email: [email protected] Website: http://www.autoflame.com/ Registered Holder: Company: Department: This manual and all the information contained herein is copyright of Autoflame Engineering Ltd. It may not be copied in the whole or part without the consent of the Managing Director. Autoflame Engineering Ltd’s policy is one of continuous improvement in both design and manufacture. We therefore reserve the right to amend specifications and/or data without prior notice. All details contained in this manual are correct at the time of going to print. Important Notes A knowledge of combustion related procedures and commissioning is essential before embarking work on any of the M.M./E.G.A. systems. This is for safety reasons and effective use of the M.M./ E.G.A. system. Hands on training is required. For details on schedules and fees relating to group training courses and individual instruction, please contact the Autoflame Engineering Ltd. offices at the address listed on the front. Short Form - General Terms and Conditions A full statement of our business terms and conditions are printed on the reverse of all invoices. A copy of these can be issued upon application, if requested in writing. The System equipment and control concepts referred to in this Manual MUST be installed, commissioned and applied by personnel skilled in the various technical disciplines that are inherent to the Autoflame product range, i.e. combustion, electrical and control. The sale of Autoflame’s systems and equipment referred to in this Manual assume that the dealer, purchaser and installer has the necessary skills at his disposal. i.e. A high degree of combustion engineering experience, and a thorough understanding of the local electrical codes of practice concerning boilers, burners and their ancillary systems and equipment. Autoflame’s warranty from point of sale is two years on all electronic systems and components. One year on all mechanical systems, components and sensors. The warranty assumes that all equipment supplied will be used for the purpose that it was intended and in strict compliance with our technical recommendations. Auto- flame’s warranty and guarantee is limited strictly to product build quality, and design. Excluded absolutely are any claims arising from misapplication, incorrect installation and/or incorrect commissioning.

Document Preview & Text Transcription

Mk8 MM Expansion Features Installation and Commissioning Guide Mk8 MM Expansion Features Installation and Commissioning Guide Issued by: AUTOFLAME ENGINEERING LTD Unit 1-2, Concorde Business Centre Airport Industrial Estate, Wireless Road Biggin Hill, Kent TN16 3YN Tel: +44 (0)845 872 2000 Fax: +44 (0)845 872 2010 Email: [email protected] Website: http://www.autoflame.com/ Registered Holder: Company: Department: This manual and all the information contained herein is copyright of Autoflame Engineering Ltd. It may not be copied in the whole or part without the consent of the Managing Director. Autoflame Engineering Ltd’s policy is one of continuous improvement in both design and manufacture. We therefore reserve the right to amend specifications and/or data without prior notice. All details contained in this manual are correct at the time of going to print.

Document Preview & Text Transcription

Mk8 MM Installation and Commissioning Guide Mk8 MM Installation and Commissioning Guide Issued by: AUTOFLAME ENGINEERING LTD Unit 1-2, Concorde Business Centre Airport Industrial Estate, Wireless Road Biggin Hill, Kent TN16 3YN Tel: +44 (0)845 872 2000 Fax: +44 (0)845 872 2010 Email: [email protected] Website: http://www.autoflame.com/ Registered Holder: Company: Department: This manual and all the information contained herein is copyright of Autoflame Engineering Ltd. It may not be copied in the whole or part without the consent of the Managing Director. Autoflame Engineering Ltd’s policy is one of continuous improvement in both design and manufacture. We therefore reserve the right to amend specifications and/or data without prior notice. All details contained in this manual are correct at the time of going to print.
AUTOFLAME Mk8 MM Manual  Main Page Preview

Manual  [PDF] (395 pages)

  • Updated: 02.07.2026

Document Preview & Text Transcription

MK8 MM MANUAL MM80001 19.05.2020 MK8 MM MANUAL MM80001 Combustion Management Systems 19 MAY 2020 Autoflame Engineering Ltd. Unit 1-2 Concorde Business Centre Airport Industrial Estate Wireless Road, Biggin Hill Kent TN16 3YN United Kingdom COMBUSTION MANAGEMENT SYSTEMS +44 (0)1959 578 820 Tel: [email protected] Email: www.autoflame.com Web: MK8 MM MANUAL MM80001 19 MAY 2020 This manual and all the information contained herein is copyright of Autoflame Engineering Ltd. It may not be copied in the whole or part without the consent of the Managing Director. Autoflame Engineering Ltd’s policy is one of continuous improvement in both design and manufacture. We therefore reserve the right to amend specifications and/or data without prior notice. All details contained in this manual are correct at the time of going to print. Important Notes A knowledge of combustion related procedures and commissioning is essential before embarking work on any of the MM / EGA systems. This is for safety reasons and effective use of the MM / EGA system. Hands on training is required. For details on schedules and fees relating to group training courses and individual instruction, please contact the Autoflame Engineering Ltd. offices at the address listed on the front. Short Form - General Terms and Conditions A full statement of our business terms and conditions are printed on the reverse of all invoices. A copy of these can be issued upon application, if requested in writing. The System equipment and control concepts referred to in this Manual MUST be installed, commissioned and applied by personnel skilled in the various technical disciplines that are inherent to the Autoflame product range, i.e. combustion, electrical and control. The sale of Autoflame’s systems and equipment referred to in this Manual assume that the dealer, purchaser and installer has the necessary skills at his disposal. i.e. A high degree of combustion engineering experience, and a thorough understanding of the local electrical codes of practice concerning boilers, burners and their ancillary systems and equipment. Autoflame’s warranty from point of sale • Two years on all electronic systems and components. • One year on all mechanical systems, components and sensors. The warranty assumes that all equipment supplied will be used for the purpose that it was intended and in strict compliance with our technical recommendations. Autoflame’s warranty and guarantee is limited strictly to product build quality, and design. Excluded absolutely are any claims arising from misapplication, incorrect installation and/or incorrect commissioning. CONTENTS 1 MK8 MM OVERVIEW, SPECIFICATIONS AND WIRING ........................................................... 13 1.1 Mk8 MM Overview ........................................................................................................................... 13 1.1.1 Mk8 MM Main Features ........................................................................................................... 14 1.1.2 Overview of Micro-Modulation (MM) ........................................................................................ 15 1.1.3 Fixing Holes and Dimensions .................................................................................................. 16 1.2 Wiring Schematic ............................................................................................................................. 17 1.2.1 Main Board ............................................................................................................................... 17 1.2.2 Expansion Board ..................................................................................................................... 18 1.2.3 Fuse Ratings ............................................................................................................................ 19 1.3 Electrical Specifications ................................................................................................................... 20 1.3.1 MM Inputs and Outputs ........................................................................................................... 20 1.3.2 Expansion Board Inputs and Outputs ...................................................................................... 21 1.3.3 Cable Specifications ................................................................................................................ 22 1.3.4 MM Terminals Description ....................................................................................................... 23 1.3.5 Expansion Board Terminals Description ................................................................................. 26 1.4 Connection Between Mk8 MM and Mk8 EGA EVO ........................................................................ 29 1.5 Connection Between Mk8 MM and Mk8 DTI ................................................................................... 30 1.6 Sequencing Connection Diagram .................................................................................................... 31 1.7 Standards......................................................................................................................................... 32 2 OPTIONS AND PARAMETERS................................................................................................... 33 2.1 Options ............................................................................................................................................. 33 2.2 Parameters ...................................................................................................................................... 57 3 COMMISSIONING PROCEDURE ................................................................................................ 67 3.1 Overview .......................................................................................................................................... 67 3.2 Installation Checks ........................................................................................................................... 68 3.2.1 Commissioning Checks ........................................................................................................... 68 3.2.2 Operational Checks ................................................................................................................. 68 3.2.3 Installation Precautions ............................................................................................................ 68 3.2.4 Maintenance and Servicing ..................................................................................................... 68 3.3 Servomotors..................................................................................................................................... 69 3.3.1 Adjusting the Servomotor Potentiometer ................................................................................. 69 3.3.2 Servomotor Feedback Voltage ................................................................................................ 70 3.3.3 Servomotors – Direction Change............................................................................................. 70 3.3.4 Servomotors with Autoflame Valves ........................................................................................ 71 3.4 Commissioning Fuel and Air Positions ............................................................................................ 72 3.4.1 Starting Commissioning ........................................................................................................... 73 3.4.2 Enter CLOSED Position ........................................................................................................... 74 3.4.3 Enter OPEN Position ............................................................................................................... 75 3.4.4 Set up START Position ............................................................................................................ 76 3.4.5 Phase Hold .............................................................................................................................. 77 3.4.6 Add Trim Data During Commissioning .................................................................................... 78 3.4.7 Commissioning VSD ................................................................................................................ 80 3.4.8 Set GOLDEN START Position ................................................................................................. 81 3.4.9 Set FGR Position ..................................................................................................................... 83 3.4.10 Set HIGH Position .................................................................................................................... 85 3.4.11 Set INTER Position .................................................................................................................. 86
AUTOFLAME Mk8 MM Technical manual Main Page Preview

Technical manual [PDF] (98 pages)

  • Updated: 20.08.2026

Document Preview & Text Transcription

Combustion Management Systems MM APPLICATION POSSIBILITIES Technical Manual 18.12.2019 AUTOFLAME ENGINEERING LTD Unit 1-2, Concorde Business Centre Airport Industrial Estate Wireless Road, Biggin Hill Kent TN16 3YN United Kingdom Combustion Management Systems +44 (0)1959 578 820 Tel: [email protected] Email: www.autoflame.com Website: Technical Manual MM Application Possibilities 18 December 2019 This manual and all the information contained herein is copyright of Autoflame Engineering Ltd. It may not be copied in the whole or part without the consent of the Managing Director. Autoflame Engineering Ltd’s policy is one of continuous improvement in both design and manufacture. We therefore reserve the right to amend specifications and/or data without prior notice. All details contained in this manual are correct at the time of going to print. Important Notes A knowledge of combustion related procedures and commissioning is essential before embarking work on any of the MM./EGA systems. This is for safety reasons and effective use of the MM/EGA system. Hands on training is required. For details on schedules and fees relating to group training courses and individual instruction, please contact the Autoflame Engineering Ltd. offices at the address listed on the front. Short Form - General Terms and Conditions A full statement of our business terms and conditions are printed on the reverse of all invoices. A copy of these can be issued upon application, if requested in writing. The System equipment and control concepts referred to in this Manual MUST be installed, commissioned and applied by personnel skilled in the various technical disciplines that are inherent to the Autoflame product range, i.e. combustion, electrical and control. The sale of Autoflame’s systems and equipment referred to in this Manual assume that the dealer, purchaser and installer has the necessary skills at his disposal. i.e. A high degree of combustion engineering experience, and a thorough understanding of the local electrical codes of practice concerning boilers, burners and their ancillary systems and equipment. Autoflame’s warranty from point of sale • Two years on all electronic systems and components. • One year on all mechanical systems, components and sensors. The warranty assumes that all equipment supplied will be used for the purpose that it was intended and in strict compliance with our technical recommendations. Autoflame’s warranty and guarantee is limited strictly to product build quality, and design. Excluded absolutely are any claims arising from misapplication, incorrect installation and/or incorrect commissioning.