Autonics SPR1 Series Manuals
4 pdf manual(s) Autonics SPR1 Series for free download (Document Types: Instruction manual, Operation & user’s manual, User manual for communication)
Autonics SPR1 Series Instruction manual [PDF] (2 pages)
- Identifier: id-1533340
- Brand: Autonics
- Device: SPR1 Series Controller
- Type: PDF
- Key Aspects: Additional Modules and Accessories Guide, Unpacking and Inspection Guidelines, Detailed Installation Instructions
- UPD Date: 09.04.2026
- Source File: 1467936.pdf
- Pages: 2
- Description: Full user manual for the Autonics SPR1 Series.
Click to expand and read text
4-Ø6 55 48 223 181 21.3 155 197.6 30 168.5 80° 55 48 223 196 21.3 15 155 212.6 30 168.5 80° 4-Ø6 80 71 250.1 238 21.3 25 187 252.6 40 184.4 4-Ø6 80° ① Bracket ② Indicator Indicator Color Function RUN Operation indicator Green LED Turns on in the RUN mode. MAN Manual control indicator Green LED Turns on when adjusting load output in the manual control mode. ALM Alarm indicator Red LED Flashes in alarming status. OUT Output indicator Red LED Turns on when load control outputs. ③ Display part: Displays settings of the front display [ DIS] parameter in RUN mode, and displays parameter and setting value in setting mode. ④ Unit indicator ( : Light ON/ : Light OFF) Indicator Display V A Resistance, load Voltage Current Power I N S T R U C T I O N M A N U A L Thank you for choosing our Autonics product. Please read the following safety considerations before use. Specifications ※1: The weight includes packaging. The weight in parenthesis is for unit only. ※Environment resistance is rated at no freezing or condensation. Ordering Information DRW171280AB Connections Wire Specification by Load Current Unit Description Model SPR1-1 SPR1-2 SPR1-3 SPR1-4 Control phase 1-phase Rated load voltage (50/60Hz) 110VACᜠ 220VACᜠ 380VACᜠ 440VACᜠ Power supply 100-240VACᜠ 50/60Hz Min. load current 1A Permissible voltage range 90 to 110% of rated voltage Power consumption Rated load current 25A/35A/50A: max. 7VA Rated load current 70A/100A/150A: max. 12VA Display method 3-digit 7-segemnet LED Indicator Operation indicator/Manual control indicator: green LED Alarm indicator/output indicator/unit (V, A) indicator: red LED Control method Phase control: normal control mode, constant current/constant voltage/ constant power feedback control mode Cycle control: fixed cycle control mode, variable cycle control mode ON/OFF control Applied load Phase control, ON/OFF control: resistance load, inductive load Cycle control: resistance load Control input Auto control: DC4-20mA, 1-5VDCᜡ, ON/OFF contact (no-voltage input), pulse voltage (5-12VDCᜡ) Manual control: outside adjuster (10kΩ), inside adjuster (output limit) Digital input (DI) RUN/STOP switching, AUTO/MAN switching, RESET Output Alarm 250VACᜠ 3A, 30VDCᜡ 3A, 1c resistive load Communication RS485 communication output (Modbus RTU method), max. connection: 31 units Output range Phase control: 0 to 98% Cycle control: 0 to 100% ON/OFF control: 0%, 100% Output accuracy Normal control: within ±10% F.S. of rated load voltage Constant current feedback control: within ±3% F.S. of rated load current Constant voltage feedback control: within ±3% F.S. of rated load voltage Constant power feedback control: within ±3% F.S. of rated load power Set method By front keys, by communication Functions Output limit (OUT ADJ), AUTO/MAN selection, control method selection, RESET, SOFT START, SOFT UP/DOWN, output high/low limit, input correction, input slope correction, monitoring (control input, load voltage/current/power/resistance, power supply frequency, heatsink temperature) Alarm Overcurrent alarm, overvoltage alarm, fuse break alarm, element error alarm, heater break alarm, heatsink overheat alarm Cooling method Rated load current 25A/35A/50A: natural cooling Rated load current 70A/100A/150A: forced air cooling (with the cooling fan) Insulation resistance Over 200MΩ (at 500VDC megger) Dielectric strength 2,000VAC 50/60Hz for 1 min (between input terminals and power terminals) Output leakage current Max. 10mArms Noise immunity ±2kV the square wave noise (pulse width: 1㎲) by the noise simulator Memory retention Approx. 10 years (when using non-volatile semiconductor memory type) Vibration Mechanical 0.75mm amplitude at frequency of 5 to 55Hz in each X, Y, Z direction for 2 hours Malfunction 0.5mm amplitude at frequency of 5 to 55Hz in each X, Y, Z direction for 10 min Environ ment Ambient temp. -10 to 55℃, storage: -20 to 80℃ Ambient humi. 35 to 85%RH, storage: 35 to 85%RH Accessory 11-pin connector Approval ᜢ Weight※1 Rated load current 25A/35A/50A: approx. 1.6kg (approx. 1.3kg) Rated load current 70A: approx. 1.65kg (approx. 1.35kg) Rated load current 100A/150A: approx. 3.2kg (approx. 2.8kg) Spacing ※�When installing multiple power controllers, please keep space at least 50mm in horizontal and 100mm in vertical between power controllers for heat radiation. While supplying power to the load or right after turning off the power of the load, do not touch the body and heatsink. Failure to follow this instruction may result in a burn due to the high temperature. High Temperature Caution 100 100 100 4-Ø6 50 Panel Panel Safety Considerations 1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.) Failure to follow this instruction may result in fire, personal injury, or economic loss. 2. Install on the device panel, and ground to the bracket separately. Failure to follow this instruction may result in electric shock or fire. 3. Do not connect, repair, or inspect the unit while connected to a power source. Failure to follow this instruction may result in electric shock or fire. 4. Check 'Connections' before wiring. Failure to follow this instruction may result in fire. 5. Do not disassemble or modify the unit. Failure to follow this instruction may result in electric shock or fire. Warning 1. Use the unit within the rated specifications. Failure to follow this instruction may result in fire or product damage. 2. Use dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in electric shock or fire. 3. Do not use the unit in the place where flammable/explosive/corrosive gas, humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present. Failure to follow this instruction may result in fire or explosion. 4. Keep metal chip, dust, and wire residue from flowing into the unit. Failure to follow this instruction may result in fire or product damage. 5. Since leakage current still flows right after turning off the power or in the output OFF status, do not touch the load terminal. Failure to follow this instruction may result in electric shock. Caution ※�The above specifications are subject to change and some models may be discontinued without notice. ※�Be sure to follow cautions written in the instruction manual, user manual, and the technical descriptions (catalog, homepage). LED Display Slim Power Controller SPR1 Series ※1: This is only for models with RS485 communication output (SPR1- T ). ※2: When connecting noise filter and capacitor, it is appropriate for EMC. CAP : Rated load voltage 110VAC-220VAC → 1uF/250VAC : Rated load voltage 380VAC-440VAC → 0.47uF/500VAC ※2 ※2 Noise filter Rapid fuse CAP Load ※Tighten the terminal screw with the below tightening torque. Rated load current Specification Alarm output/ power input Load output S R, U 25A, 35A, 50A, 70A Screw M3 M3 M6 Tightening torque 0.5N.m 0.5N.m 5.5 to 6.0N.m 100A, 150A Screw M3 M3 M8 Tightening torque 0.5N.m 0.5N.m 6.5 to 7.0N.ma b c Terminal type Terminal number a b c Input (11-pin) 1 to 11 6 to 7 Max. 1.5 Max. 3.5 ※Use crimp terminals or terminals of size specified below. a b Terminal type a b Alarm output/power input Min. 3.0 Max. 6.0 Load output S Min. 3.0 Max. 8.0 R, U Rated load current 25A/35A/50A/70A Min. 6.0 Max. 16.0 Rated load current 100A/150A Min. 8.0 Max. 26.0 (unit: mm) ⑤ key: Enters parameter group, returns to RUN mode, moves parameters, and saves the setting value. ⑥ Setting value adjustment key : Enters SV setting mode and move digits. ⑦ Output limit adjuster (OUT ADJ) : Limits output from 0 to 100%. ⑧ 11-pin connector terminal ⑨ Terminal cover ⑩ Alarm output and power input terminals ⑪ R, S, U load output terminals ⑫ Cooling fan: For models with the rated load current of 70A/100A/150A, a cooling fan is attached. ⑬ Heatsink Rated load current Wire specification Alarm output/ power input Load output S R, U 25A/35A/50A/70A AWG 18 to 14 AWG 18 to 14 AWG 13 to 4 100A/150A AWG 4 to 2/0 (unit: mm) ※Please observe all safety considerations for safe and proper product operation to avoid hazards. ※ symbol represents caution due to special circumstances in which hazards may occur. Warning Failure to follow these instructions may result in serious injury or death. Caution Failure to follow these instructions may result in personal injury or product damage. ※1: Product is not equipped with a rapid fuse inside. Install the suitable fuse for rated load current of the model separately. (The performance of the product is guaranteed only when using the fuse provided by us.) SPR Solid State Power Regulator N Non-fuse※1 F Fuse N Normal control F Normal/constant current/constant voltage/constant power control N Alarm output T Alarm+RS485 comm. output 1 110VAC 2 220VAC 3 380VAC 4 440VAC 1 1-phase 25 25A 35 35A 50 50A 70 70A 100 100A 150 150A 1 T F SPR 70 2 F Control phase Item Rated load current Rated load voltage Fuse Option output Feedback control ① ⑧ ⑨ ⑦ ⑤ ③ ② ⑫ R U ⑫ ⑬ S ⑩ ⑪ ⑥ ④ Control input/Comm. output Alarm output/power input Load output Alarm Output (250VAC 3A 1c) (30VDC 3A 1c) Resistive Load 100-240VAC 50/60Hz 1 2 3 4 5 N.C. N.O. L COM N ※1 ① ② ③ ④ ⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪ VR ON/OFF 4-20mA 1-5 VDC RUN/STOP AUTO/MAN RESET RS485 A(+) B(-) R S U Rated load current 25A/35A/50A Rated load current 100A/150A Rated load current 70A Dimensions 6.8 6.8 6.8 Removing the Case Replacement of Fuse ② ① Case fixing bolts Spec. of case fixing bolts Rated load current Spec. of bolts 25A, 35A, 50A, 70A M3 100A, 150A M4 Fuse fixing bolts Fuse For replacing the fuse, please use the recommended fuse which has the below specifications. (manufacture: BUSSMANN) ※The performance of the product is guaranteed only when using the fuse provided by us. Recommended fuse specifications Spec. of fuse fixing bolts Rated load current Spec. of bolts 25A, 35A, 50A, 70A M6 100A, 150A M8 Rated load current Model Rated load current Model Rated load current Model 25A 50FE 50A 80ET 100A FWH-150B 35A 63ET 70A 100FE 150A FWH-200B
Autonics SPR1 Series Operation & user’s manual [PDF] (14 pages)
- Identifier: id-1533341
- Brand: Autonics
- Device: SPR1 Series Controller
- Type: PDF
- Key Aspects: Component Overview and Descriptions, Risk Mitigation and Accident Prevention, Technical Support and Resource Links
- UPD Date: 18.07.2026
- Source File: 1467935.pdf
- Pages: 14
- Description: Professional manual for the Autonics SPR1 Series.
Click to expand and read text
I-30 SPR1 Series LED Display, Single-Phase, Slim, Power Controller Manual Ordering Information ● For the detail information and instructions, please refer to user manual for communication, and be sure to follow cautions written in the technical descriptions (catalog, homepage). Visit our homepage (www.autonics.com) to download manuals. ● User manual for communication manual describes for RS485 communication (Modbus RTU protocol) and parameter address map data. Comprehensive Device Management Program (DAQMaster) ※1: Product is not equipped with a rapid fuse inside. Install the suitable fuse for rated load current of the model separately. (The performance of the product is guaranteed only when using the fuse provided by us.) Control phase Item Rated load current Rated load voltage Fuse Option output Feedback control N Non-fuse※1 F Fuse N Normal control F Normal/constant current/constant voltage /constant power control N Alarm output T Alarm+RS485 comm. output 25 25A 70 70A 35 35A 100 100A 50 50A 150 150A 1 110VAC 2 220VAC 3 380VAC 4 440VAC 1 Single-phase SPR Solid State Power Regulator (slim type) 1 T F SPR 70 2 F ● DAQMaster is a comprehensive device management software for setting parameters and monitoring processes. ● Visit our website (www.autonics.com) to download user manual and comprehensive device management program. < DAQMaster screen > < Computer specification for using software > Item Minimum specifications System IBM PC compatible computer with Pentium Ⅲ or above Operations Windows 98/NT/XP/Vista/7/8/10 Memory 256MB+ Hard disk 1GB+ of available hard disk space VGA Resolution: 1024×768 or higher Others RS232C serial port (9-pin), USB port Please read “Safety considerations” in operation manual before using. Features Refine and slim body design LED display for real time monitoring (control input, load voltage, load current, load power, load resistance and heatsink temperature) and checking parameter settings Stable control by feedback control (constant current/constant voltage/constant power control) Communication output model available: RS485 (Modbus RTU method) Convenient parameter settings via PC (RS485 communication) : Free download the comprehensive device management program (DAQMaster) Various alarm functions (alarm output) : overcurrent, overvoltage, heatsink overheat, fuse break, SCR error Easy installation of the bracket Simple fuse replacement structure for easy maintenance Highly reliable SCR (IXYS) element
Autonics SPR1 Series User manual for communication [PDF] (22 pages)
- Identifier: id-1819010
- Brand: Autonics
- Device: SPR1 Series Controller
- Type: PDF
- Key Aspects: Additional Modules and Accessories Guide, Control Panel and Interface Navigation, Unpacking and Inspection Guidelines
- UPD Date: 06.09.2026
- Source File: 1903756.pdf
- Pages: 22
- Description: Official operating instructions for the Autonics SPR1 Series.
Click to expand and read text
© Copyright Reserved Autonics Co., Ltd. i
Autonics SPR1 Series User manual for communication [PDF] (26 pages)
- Identifier: id-1990123
- Brand: Autonics
- Device: SPR1 Series Controller
- Type: PDF
- Key Aspects: Component Longevity Optimization, Cleaning and Sanitization Methods, Initial Startup Checklist
- UPD Date: 16.03.2026
- Source File: 2297735.pdf
- Pages: 26
- Description: User guide for the Autonics SPR1 Series.
Click to expand and read text
User Manual for Communication Power Controllers SPR Series Thank you for purchasing an Autonics product. This user manual contains information about the product and its proper use, and should be kept in a place where it will be easy to access. www.autonics.com
Autonics SPR1 Series: Controller Category Related Instructions
Reference Guide It’s Under Control® KX7s In-Wall Controller If you are encountering any problems or have a question about your RTI product, please contact RTI Technical Support for assistance (see the Contacting RTI section of this guide for contact details Comprehensive operating guide for the RTI KX7s Controller. This guide explains technical procedures for operating modes, installation guides, safety protocols.
Document Revision: 8.D Web Configurator Template Revision: 72 ProtoNode FPC-N34 and ProtoNode FPC-N35 Start-up Guide For Interfacing Weil-McLain Products: Unity 1.0 Control, SlimFit 1000-2000 Series 1 (SF_SOLA) To Building Automation Systems: BACnet MS/TP, Complete device guide for the Weil-McLain ProtoNode FPC-N34 Controller. It details operating modes and service contacts, product safety, safety protocols, error codes.
Solenoid Kit ic dosetroniicc English Instruction Manual Version B1.0 : 270812 ©copyright 2012, all rights reserved, Bluelab Corporation Limited Batch Controller User operation guide for the bluelab Dosetronic Controller. It explains software configuration, network configuration, menu navigation.
OPERATING GUIDE Put Bar Code Here 63-2730-01 Stryker VAV Zio Configuration TABLE OF CONTENTS Zio Configuration Scope ..................................................................................................................................2 Home Screen Device operation guide for the Honeywell Stryker VAV Controller. The manual elaborates on features and setup tips, device instructions, performance guidelines, connectivity options.