Document Preview & Text Transcription
Chelan B-Vent
(700 B-Vent)
Gas Stove
and
Fireplace Insert
¥ Freestanding Stove
¥ Masonry Fireplace Insert
¥ Factory Built (Z.C.) Fireplace
Insert
Listed
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency, or the gas supplier.
-
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
- I nst al l at i on m us t be per for m ed by a qual i f ie d i ns ta l le r, s er vic e a gency or the ga s s uppl i er
IF YOU SMELL GAS
¥ Do not try to light any appliance.
¥ Do not touch any electrical switch; do not use any phone in your building.
¥ Immediately call gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
¥ If you cannot reach your gas supplier, call the fire department.
- April, 1999 -
Installer: After installation give this manual
to the homeowner and explain
operation of this heater.
$10.00
93508078
10850 117th Place N.E. Kirkland, WA 98033
PAGE 2
SAFETY PRECAUTIONS
¥ IF YOU SMELL GAS:
* Do not light any appliance
* Extinguish any open flame
* Do not touch any electrical switch or plug or unplug anything
* Open windows and vacate building
* Call gas supplier from neighbor's house, if not reached, call fire
department
¥
This unit must be installed by a qualified installer to prevent the possibility of
an explosion. Your dealer will know the requirements in your area and can
inform you of those people considered qualified. The room heater should be
inspected before use and at least annually by a qualified service person. More
frequent cleaning may be required due to excessive lint from carpeting,
bedding material, etc.
¥
The instructions in this manual must be strictly adhered to. Do not use
makeshift methods or compromise in the installation. Improper installation
will void the warranty and safety listing.
THIS CONTROL
HAS BEEN
CONVERTED TO
LP
THIS CONTROL
HAS BEEN
CONVERTED FOR
NATURAL GAS
¥
This heater is either approved for natural gas
(NG) or for propane (LP). Burning the incorrect
fuel will void the warranty and safety listing and
may cause an extreme safety hazard. Direct
questions about the type of fuel used to your
dealer. Check the label on top of the gas control
valve.
Ok
¥
Contact your local
building officials to
obtain a permit and
information on any
installation restrictions or
inspection requirements
in your area. Notify your
insurance company of this
heater as well.
¥
If the flame becomes
sooty, dark orange in
color, or extremely tall,
do not operate the heater.
Call your dealer and
arrange for proper
servicing.
¥
It is imperative that
control compartments,
screens, or circulating air
passageways of the heater
be kept clean and free of
obstructions. These areas
provide the air necessary
for safe operation.
?
¥
Do not operate the heater
if it is not operating
properly in any fashion or
if you are uncertain. Call
your dealer for a full
explanation of your heater
and what to expect.
Gas
¥
Do not store or use
gasoline or other
flammable liquids in the
vicinity of this heater.
¥
Keep all furniture or other
combustible items at least
36" away from the front
of the heater.
AAAA
AAAA
AAAA
AAAA
AAAA
AAAA
A
A
¥
Do not operate if any
portion of the heater was
submerged in water or if
any corrosion occurs.
SAFETY PRECAUTIONS (CONTINUED)
PAGE 3
¥
Do not place clothing or
other flammable items on
or near the heater.
Because this heater can be
controlled by a thermostat
there is a possibility of the
heater turning on and
igniting any items placed
on or near it.
AA
AA
AA
AA
A
¥
Light the heater using the
built-in piezo igniter. Do
not use matches or any
other external device to
light your heater.
¥
Never remove, replace,
modify or substitute any
part of the heater unless
¥
The viewing glass should
be opened for service
only (see the maintenance
section of this manual).
¥
Any safety screen or
guard removed for
servicing must be
replaced prior to
operating the heater.
instructions are given in
this manual. All other
work must be done by a
trained technician. Don't
modify or replace
orifices.
¥
Allow the heater to cool
before carrying out any
maintenance or cleaning.
¥
Operate the heater
according to the
instructions included in
this manual.
¥
If the main burners do not
start correctly turn the gas
off at the gas control
valve and call your dealer
for service.
¥
The pilot flame must
contact the thermopile
and thermocouple (see the
illustration to the left). If
it does not, turn the gas
control valve to "OFF"
and call your dealer.
A
A
A
A
¥
This unit is not for use
with solid fuel
¥
Do not place anything
inside the firebox (except
the included fiber logs).
¥
If the fiber logs become
damaged, replace with
Travis Industries log set.
This
Manual
¥
Do not throw this manual
away. This manual has
important operating and
maintenance instructions
that you will need at a
later time. Always follow
the instructions in this
manual.
¥
Do not touch the hot
surfaces of the heater.
Educate all children of the
danger of a high-
temperature heater.
Young children should be
supervised when they are
in the same room as the
heater.
¥
Plug the heater into a
115V grounded electrical
outlet. Do not remove the
grounding plug.
¥
Don't route the electrical
cord in front of, over, or
under the heater
¥
Instruct everyone in the
house how to shut gas off
to the appliance and at the
gas main shutoff valve.
The gas main shutoff
valve is usually next to
the gas meter or propane
tank and requires a
wrench to shut off.
¥
Travis Industries, Inc.
grants no warranty,
implied or stated, for the
installation or
maintenance of your
heater, and assumes no
responsibility of any
consequential
damage(s).