Manual [PDF] (40 pages)
- Updated: 18.07.2026
Document Preview & Text Transcription
AYM-07P
Local airconditioner
Specialist’s Manual.................................................................................................35
Content
Operation Notices
The Refrigerant .........................................................................................................1
Operation Environment ............................................................................................3
Safety Warning .........................................................................................................2
Part's Name ..............................................................................................................4
Operation Guide
Operation Introduction for Control Panel .................................................................5
Buttons on Remote Controller .................................................................................7
Introduction for Icons on Display Screen .................................................................7
Introduction for Buttons on Remote Controller .........................................................8
Function Introduction for Combination Buttons ......................................................12
Operation Guide .................................................................................................... 13
Replacement of Batteries in Remote Controller .....................................................1 3
Maintenance
Clean and Maintenance..........................................................................................14
Malfunction
Malfunction Analysis ..............................................................................................16
Installation Notice
Installation Precaution ...........................................................................................19
Preparation before Installation ...............................................................................21
Installation
Removing Collected Water ....................................................................................23
Install Wire Hook ...................................................................................................22
Operation Test .......................................................................................................34
Installation in a double-hung sash window(Optional) ............................................25
Installation in a sliding sash window(Optional) ......................................................28
Installation and Disassembly of Heat Discharge Pipe ...........................................31
Attached Sheet
Electric Schematic Diagram...................................................................................34
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from un-
controlled waste disposal, recycle it responsibly to promote the sustainable reuse of mate-
rial resources. To return your used device, please use the return and collection systems or
contact the retailer where the product was purchased. They can take this product for envi-
ronmental safe recycling.
R290: 3
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
The Refrigerant
WARNING
To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The used refrigerant is the fluoride R290, which is specially cleaned.
The refrigerant is flammable and inodorous. Furthermore, it can leads to explosion
under certain conditions.
Compared to common refrigerants, R290 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R290
has got very good thermodynamic features which lead to a really high energy
efficiency. The units therefore need a less filling.
Please refer to the nameplate for the charging quantity of R290.
Ducts connected to an appliance shall not contain an ignition source.
Appliance filled with flammable gas R290.
Before install and use the appliance, read the owner’s manual first.
Before install the appliance, read the installation manual first.
Before repair the appliance, read the service manual first.
Appliance filled with flammable gas R290.
Appliance shall be installed, operated and stored in a room with a floor area larger
The appliance shall be stored in a room without continuously operating ignition sources .
(for example: open flames, an operating gas appliance or an operating electric heater.)
The appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specified for operation.
The appliance shall be stored so as to prevent mechanical damage from occurring.
Keep any required ventilation openings clear of obstruction.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
Servicing shall be performed only as recommended by the manufacturer.
Should repair be necessary, contact your nearest authorized Service Centre.
Any repairs carried out by unqualified personnel may be dangerous.
Compliance with national gas regulations shall be observed.
Read specialist’s manual.
than 11 m .
2
1