B.E.G. LUXOMAT PD2-M-1C Manuals

1 pdf manual(s) B.E.G. LUXOMAT PD2-M-1C for free download (Document Types: Installation and operating instruction)

B.E.G. LUXOMAT PD2-M-1C Installation and operating instruction [PDF] (2 pages)

  • Identifier: id-1290339
  • Brand: B.E.G.
  • Device: LUXOMAT PD2-M-1C Security Sensors
  • Type: PDF
  • Key Aspects: Cleaning and Sanitization Methods, Device Specifications Overview, Unpacking and Inspection Guidelines
  • UPD Date: 15.04.2026
  • Source File: 1297363.pdf
  • Pages: 2
  • Description: User operation guide for the B.E.G. LUXOMAT PD2-M-1C.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 1 2 2 120 6050 40 30 15 10 A 16 10 5 2 1 30 15 TEST 2000 1200 600 200 40 5 2000 1200 600 200 40 B.I.T. Q.C. PASSED 1 2000 1200 600 200 40 120 6050 40 30 15 10 A 16 10 5 2 1 30 15 TEST 2000 1200 600 200 40 5 120 6050 40 30 15 10 A 16 10 5 2 1 30 15 TEST 2000 1200 600 200 40 5 IR-PD IR-PD-Mini 3. Putting into operation / Settings Follow-up time for light control The time can be set infinitely variably at between 15 seconds and 16 minutes. Symbol : impulse < 1sec. Symbol TEST: Test mode (Every movement switches on the light for a period of 1 second, switching it off for a period of 2 seconds after that regardless of the level of brightness.) Twilight-switch for light control (relay 1) The switch-on value for the light can be set at between 10 and 2000 Lux. Using the rotary control, the luminance set points can be set as desired. Symbol : Night-time operation Symbol : Daytime/Night-time operation Installation and Operating Instruction for B.E.G. - Occupancy detectors PD2-M-1C-SM/-FC/-FM The detector can be installed in conventional inlet-sockets mounted on the ceiling. The assembly plate enclosed must be stripped off prior to installation and secured to the ceiling using 4 screws and ensuring that it is not laterally transposed. Having connected up the cables in accordance with regulations, the detector can be placed in position as shown in the drawing opposite and, applying a little pressure, can then be locked into position with the assistance of the spring clips. 2a. Installation of the LUXOMAT® PD2-M-1C-SM 2c. Installation of the LUXOMAT® PD2-M-1C-FM The detector must be in- stalled on a solid and level surface. There is no need for frames. For mounting remove lens (C) (turn anticlockwise). Fasten the mounting pod to the ceiling. Having connected up the wires in accordance with regulations, secure the detector with 2 screws as per the illustration above. In order to assemble the detector outside, the PD2-IP54 base-plate, which is available as an accessory, must be mounted between the detector and the surface on which it is to be installed. Unlocking device Lock device 4. Settings carried out using remote control (optional) Remote control LUXOMAT IR-PD 1. Check Battery: open battery compartment by pressing the plastic springs together and removing the battery-holder. 2. IMPORTANT Please pay attention, that the setting is Potentio- meter 1 at “TEST” and Potentiometer 2 not at “SUN”. All values which have been programmed using the remote control will be deleted in the event of power failure in the position “TEST/ SUN”. Please switch Potentiometer 2 over to “MOON” or any other value. Caution: Settings with remote control supersede the settings by courtesy of potentiometers. LUXOMAT® PD2-M-1C 1. Mounting preparations Work on the 230V mains supply may only be carried out by qualified professionals or by instructed persons under the direction and supervision of qualified skilled electrical person- nel in accordance with electrotechni- cal regulations. Disconnect supply before installing! When in Master/Slave mode of operation, the Master-appliance must always be installed at the location where there is least daylight. Lock device Test mode Reset to deactivate Resetting when closed The lighting relay is switched off, i.e. opened and the follow-up times reset. Permanent protection against sabotage This function blocks the unit permanently (green LED is illuminated). This operating mode can only be activated during the period of 5 seconds after pressing the “lock“ button. This status will only permit actuating the function “Light on/Light off”. The procedure for leaving this mode is as follows: 1. Switch off the current 2. Apply current for 31 – 59 seconds 3. Switch of the current again 4. Apply current 5. Open detector Light on/off The light will remain switched on/off for as long as movements are detected in the areas of coverage. Once the last movement has been detected, the light will remain on for the duration of the follow-up time as per setting. The appliance will then return independently to the mode selected (Fully or Semi-automatic). 2b. Installation of the LUXOMAT® PD2-M-1C-FC The detector has been designed and developed specifically for instal- lation in suspended ceilings. A circular opening of diameter 68 – 70mm must be produced in the ceiling. Having connected up the cables in accor­ dance with regulations, the detector is inserted into the opening as shown in the drawing opposite and fixed into position with the assistance of the spring clips. Option: Wall bracket for remote control IR-PD 2d. Self test cycle The product enters an initial 60-sec- ond self-test cycle, when the supply is first connected. The occupancy detector is ready for operation.   max 50 Lux 1500 Lux ON OFF max 50 Lux 1500 Lux ON OFF       max 50 Lux 1500 Lux ON OFF Luminance set point Automatic reading in the current light value as new luminance set point Individual light value 2 - 2500Lux Follow-up time (relay and channel 1) 15sec. up to 30min. Impulse function (relay and channel 1) 1sec. ON, 9sec. OFF Preset/user mode Fully automatic/semi automatic mode => (see page 2, point 5) Semi automatic: red LED (flashing), Fully automatic: red LED on for approx. 3sec. Resetting when open All values which have been programmed using the remote control IR-PD are deleted, and those values which have been set by potentiometer are activated. 120 6050 40 30 15 10 A 16 10 5 2 1 30 15 TEST 2000 1200 600 200 40 5 120 6050 40 30 15 10 A 16 10 5 2 1 30 15 TEST 2000 1200 600 200 40 5 GB

B.E.G. LUXOMAT PD2-M-1C: Security Sensors Category Related Instructions

iWave RWX95
Risco iWave RWX95
24.07.2026 2 pages

x 2 x 3 < 36kg (80lb) x 2 T 1 4 5 6 -10°C > 55°C (14°F > 131°F) IT ES FR PR EN NL PIR 915 MHz Model: RWX95 Registering the Detector into the system The iWave must identify itself to the system receiver. This can be done by typing the 11 digit serial numbe Operation and maintenance manual for the Risco iWave RWX95 Security Sensors. This documentation provides step-by-step guidance on menu navigation, regulatory notices, testing procedures, reset instructions.

MILLER 1032363
Honeywell MILLER 1032363
17.08.2026 48 pages

1 90023116 ind B 26/08/2013 NT90023116 IND B.indd 1 9.9.2013 14:19 all-guides. com Device setup manual for the Honeywell MILLER 1032363 Security Sensors. The manual outlines system configuration and testing procedures, technical guidelines, application scenarios, installation steps.

Searchline Excel
Honeywell Searchline Excel
03.05.2026 2 pages

1 2 11 12 13 14 Installation Guide Issue 6 07/2017 MAN0558_EMEAI 2104M0510 © 2017 Honeywell Analytics Searchline Excel Open Path Infrared Gas Detector Find out more www.honeywellanalytics.com Contact Honeywell Analytics: Europe, Middle East, Africa, India Lif Instruction reference guide for the Honeywell Searchline Excel Other. It provides technical information on compatibility information, hardware instructions, product specifications, troubleshooting tips.

EK4000 Series
Intermatic EK4000 Series
28.07.2026 2 pages

• Disconnect power at the circuit breaker(s) or disconnect switch(es) before beginning installation or servicing. • Do NOT use the OFF state of the photocontrol for equipment servicing. Risk of Fire or Electric Shock ELECTRONIC PHOTOCONTROL Installation an Instruction and usage manual for the Intermatic EK4000 Series Security Sensors. This guide includes software updates, compatibility information, hardware components, startup procedures.