Operation & user’s manual [PDF] (16 pages)
- Updated: 25.03.2026
Document Preview & Text Transcription
Flow Sensors
Wireless Flow Sensor System
Series 228PV
User Manual
SEN-UM-01662-EN-05 (March 2017)
Flow Sensors, Wireless Flow Sensor System
Page ii
March 2017
SEN-UM-01662-EN-05
CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Series 228PV Wireless Flow Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Wireless ORION RF Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Wireless ORION RF Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Wireless 228PV Plastic Tee Sensor and Transmitter Mechanical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Wireless Receiver Mechanical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Antenna Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wireless Receiver Electrical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Theory of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Programming Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Wireless Receiver Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Wireless Flow Sensor Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Introduction
Page 3
March 2017
SEN-UM-01662-EN-05
INTRODUCTION
The Series 228PV wireless flow sensor system from Badger Meter® consists of the flow sensor mounted in a tee (flow sensor
assembly), ORION® radio frequency (RF) transmitter complete with mounting kit, and ORION RF receiver/pulse transmitter .
This system eliminates the need for expensive signal wires from the sensor output .
The battery powered flow sensor performs flow measurement and scaling and then transmits a total flow value to the RF
transmitter . The transmitter sends an RF signal approximately every four seconds that the RF receiver detects . The RF receiver
compares the previous flow total with the most recent flow total to generate a pulse output . Using the PC software, which
is part of the software installation kit, the pulse output can be scaled to represent the desired volume unit and number of
output pulses per unit volume that best fits the application . Pulse width can also be adjusted to meet the requirements of an
interfacing control system or monitor .
LICENSE REQUIREMENTS
ORION Fixed Network, Migratable and Classic endpoints comply with Part 15 of FCC Rules . ORION Cellular endpoints comply
with Part 15, Part 22 and Part 24 of FCC Rules . Operation is subject to the following conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation of the device .
In accordance with FCC Regulations, “Code of Federal Regulations” Title 47, Part 2, Subpart J, Section 1091, transmitters
pass the requirements pertaining to radiation exposure . However, to avoid public exposure in excess of limits for general
population (uncontrolled exposure), a 20 centimeter distance between the transmitter and the body of the user must be
maintained during operation .
No FCC license is required by a utility to operate an ORION meter reading system .
This device complies with Industry Canada license-exempt RSS standard(s) . Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device .
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence .
L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur
de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre
le fonctionnement .
IMPORTTNT
Transportation: The Federal Aviation Administration prohibits operating endpoints and receivers on all commercial aircraft. The
ORION endpoint is considered an operating transmitter and cannot be shipped by air.