I.
Introduction
The microprocessor-controlled Max Charge MC-612 is the most advanced regulator available. The MC-612 lets
you choose from a variety of selectable preset programs to best suit your charging needs. Its Universal Factory
Program allows you to connect the MC-612 to your alternator right out of the box. Six additional preset pro-
grams support most popular battery types, including standard and deep-cycle flooded batteries, AGM, gel, and
Optima (spiral wound) technologies, as well as special settings for systems supplying halogen lighting. An easy-
to-use magnetic reed switch delivers quick, precise regulator adjustment. Should your charging system require
individualized adjustment, the MC-612 provides additional advanced user-defined programming options.
When used with optional alternator and battery temperature sensors, the MC-612 automatically monitors ambi-
ent alternator and battery temperatures and compensates by adjusting field output to match conditions. Alarm
outputs connect to audible or visual alarms to provide warnings of dangerous system conditions.
II. Safety Considerations
Before installing your MC-612 marine regulator, please take a moment to consider these guidelines for safe reg-
ulator installation. Failure to work safely could result in injury or damage to your electrical system.
1.
Always disconnect your battery banks and ensure that switches are “OFF” prior to installing your regulator.
2.
Remove loose-fitting clothing or jewelry, which could become entangled in your motor or other machinery.
3.
Wear ANSI-approved safety glasses.
4.
DO NOT attempt to modify the regulator. Alterations could result in damage to your charging system, and will void
your warranty.
5.
Do not attempt installation if tired or fatigued.
6.
Ensure the engine has cooled before initiating installation.
7.
Do not attempt installation while using alcohol or medication that could impair your judgment or reaction time.
8.
Always use the right tool for the job. Improper tool use may damage regulator or your boat, and could result in per-
sonal injury.
9.
Take time to read the manual. Equipment damage and possible injuries may result from an incomplete understand-
ing of the installation and operation of the MC-612 regulator. If you are unfamiliar with marine electrical systems,
consult with a licensed marine electrician.
I.
Introduction ........................................................1
II.
Safety Considerations ........................................1
III. Installation Guide............................................2-5
IV. Optional Wiring Connections ........................5-6
V.
Regulator Operation ..........................................7
VI. Regulator Display Modes ..................................8
VII. Programming Modes ....................................9-11
VIII. System Troubleshooting............................12-13
IIX. Suggested Wiring Configurations..............14-15
Express Installation Instructions ..........................16
Warranty....................................................................16
TABLE OF CONTENTS
- 2 -
III. Installation Guide
The following information is intended to provide the installer with the basic information required to complete
installation. This section of the installation manual will deal with mounting, wiring connections and basic pro-
gramming for battery type. Additional information regarding advanced programming adjustments and trou-
bleshooting are addressed later in the manual.
Caution
The following instructions are intended for use by experienced marine electrical installers. If you
are not experienced at installing electrical system components, we recommend the use of a qual-
ified marine electrical technician.
A. Unpack The Box
Your Max Charge MC-612-H regulator kit is packaged with the
following items:
1.
Max Charge regulator
2.
54” wiring harness w/ fuse (10A) on RED power wire
3.
Fused (1A) battery sense wire pigtail
4.
Magnetic programming tool
5.
Installation and operation manual
If any of the listed items is not included with your regulator kit,
call our customer service department at 360-435-6100. Please note -- if your regulator box is marked Max
Charge MC-612, without the “H” designation, your kit will not include the wiring harness or fused battery sense
pigtail.
1
2
3
4
5
B. Locate And Mount The Regulator
Choosing a mounting location for your voltage regulator should be deter-
mined based on the following factors; distance from alternator, distance
from inverters, transmitters and other sources of RF noise, convenient
access and readability of the display. The regulator wiring harness is 54
inches long, providing a three to four foot radius for mounting.
Ample airflow is essential for the regulator’s proper operation. Ensure
that the regulator is free from obstructions that restrict air movement
around or below the regulator’s heat aluminum heat sink.
Should it be necessary to install the regulator further than the harness’s
54” length from the alternator, ensure that any wire extensions are prop-
erly connected, as resistance in the harness wiring can reduce charging
efficiency or hamper the regulator’s ability to accurately respond to bat-
tery conditions. If harness length must reach beyond approximately eight
feet, replace the existing harness wires with larger gauge wire.
C. Basic Wiring Installation (Topics D to K)
The regulator’s wiring harness includes six wires required for standard
installation. Four of those wires are connected to the regulator via a
Ford-style plug connector that’s pre-installed on the regulator. These
wires include the Ground (BLACK), Power (RED), Ignition (BROWN)
and Field (BLUE). Plug is shown at right. In addition, the harness
includes a separate Ground (BLACK) and Stator (WHITE) wire. The
proper terminal connection points for these, and additional wiring con-
nections, are illustrated on the pin location legend shown and discussed
on the following pages.
- 3 -
MC-612 Regulator Layout
1.
Magnetic Reed Switch - Activated by placing
magnetic tip of programming tool against one or
the other end. See illustration in “Programming”
section later in this manual.
2.
Positive Sense Wire - Connects to independent
fused wire included with regulator. Wire must
see battery voltage directly for proper operation.
See details in text.
3.
Ground (Independent) - Connects to individual
ground (BLACK) wire in wiring harness. Pre-
connected at factory in regulator packages with
harness included.
4.
Ground (BLACK) - Included in Ford-style plug.
5.
Power (RED) - Supplies power to operate the
regulator and delivers field current to excite
alternator. Included in Ford-style plug.
6.
Ignition (BROWN) - Serves as “ON/OFF switch”
for regulator. Must see zero volts when enging
ignition is off and battery voltage when the igni-
tion is on. May also be activated by an oil pres-
sure switch. Included in Ford-style plug.
7.
Field (BLUE) - Supplies amperage to the alter-
nators brushes to excite the regulator. The regu-
lator will increase or decrease voltage/amperage
on the field to maximize charging without
exceeding safe operating voltages. Included in
Ford-style plug.
8.
Digital Numeric Display - Three-digit numeric dis-
play provides an easy-to-use interface for operational
and programming modes.
9.
Stator Input - Connects (WHITE) stator input from
alternator to tach output to electric tachometer.
When the tachometer is connected to the alternator
via the regulator’s Stator Input and Tach Output
(#10), the regulator will automatically enable a min-
imum field current value, which will minimize tach
bounce when the batteries reach full charge.
10. Tach Out - Connects alternator stator output to an
electric tachometer via the regulator. See informa-
tion above.
11. Data RX - Not currently used. Provides input connec-
tion for planned remote display.
12. Data TX - Not currently used. Provides output con-
nection for planned remote display.
13. Alternator Temperature Sensor - Positive and nega-
tive terminal pins for use with optional Alternator
Temperature Sensor (MC-TS-A). When connected,
the temperature sensing function allows the regula-
tor to respond to over-temperature conditions at the
alternator by reducing field output to the alternator.
Reducing field output reduces load on alternator and
belts, allowing the alternator to cool down. In addi-
tion, the regulator activates the Dash Lamp terminal
(#17) so a warning lamp or audible alarm can be
used to indicate an over-temperature condition.
14. Battery #2 Temperature Sensor - Indicates over-
temperature condition at secondary battery bank,
when used with optional Battery Temperature
Sensor (MC-TS-B). Regulator discontinues field cur-
rent to the alternator when high battery temperature
is sensed. Activates Dash Lamp (#17) when condi-
tion is indicated.
15. Battery #1 Temperature Sensor - Automatically
compensates for changes in ambient battery temper-
ature when used with optional Battery Temperature
Sensor (MC-TS-B). Regulator discontinues field cur-
rent to the alternator when high battery temperature
is sensed. Activates Dash Lamp (#17) when condi-
tion is indicated.
16. Aux. 1 Output - Terminal goes to ground when the
following conditions occur: alternator output at full
capacity, Small Engine Mode activated, Equalization
Mode activated. Can be connected to ground side of
lamp or audible alert device.
17. Dash Lamp - Terminal goes to ground when the fol-
lowing conditions occur: low system voltage, high
system voltage, high alternator temperature, high
battery temperature. Can be connected to ground
side of lamp or audible alert device.
Pages Preview: