Run a drain line from the evaporator
coil drain to the pump. Use the flexible
plastic pipe where the code permits.
Insert the pipe 1” below the pump
cover. Do not install inlet drain line that
would interfere with operation of floats.
Connect outlet tubing (copper or vinyl)
to discharge on pump. Do not run
tubing vertical more than is
recommended by the lift on each unit.
For good flow, slant the horizontal run
downward toward the drain. Each unit
comes standard with a check valve for
connecting to ½” O.D. copper tubing. A
copper tube adapter is included for vinyl
hose hook-up.
RULES FOR SAFE OPERATION
1.
Carefully read the Owners Manual and rules for safe operation.
2.
All wiring must conform to local codes. Use the National Electric Code if
local code is nonexistent.
3.
CAUTION! To reduce risk of electric shock disconnect from power supply
before servicing, pull the plug on models which have plug-in connections.
4.
Do not handle the pump with wet hands or when standing in water as fatal
shock could occur. Disconnect main power before handling unit for ANY
REASON!
5.
Protect the power cable from coming in contact with sharp objects.
6.
Do not kink power cable and never allow the cable to come in contact with
oil, grease, hot surfaces or chemicals.
7.
Make certain that line voltage conforms to the voltage specified on motor
and nameplate.
8.
WARNING! To reduce risk of electrical shock, connect only to a properly
grounded grounding type receptacle.
INSTALLATION
Select a location for the pump. It should be
as near as possible to the air conditioning
coil but avoid any water spray or drops on or
near the motor and switch cover. The pump
must be level. The inlet hole must be below
the coil drain.
Carefully unpack the pump. Remove the
switch cover. Check each float rod for “free”
action.
PIPING
COVER
PRIMARY SWITCH
TERMINAL BLOCK
FLOAT
TANK
STAND
OUTLET
INLET
MOTOR
SAFETY SWITCH
Designated
Pump Lift
Copper Tube
Vinyl Hose
Evaporator
(“A” Coil)
Inner Ring
92318_RevC
MODEL: CB501ULHTS, CB502ULHTS, CB504ULHTS, CP651ULHTS, CP654ULHTS
Nut
Check Valve
Ball-Cage
Snap Ring
Ball
Adapter
Read and Follow all Safety Instructions.
Save This Manual for Future Reference.
CONDENSATE REMOVAL PUMP
LIMITED WARRANTY
Each Beckett Corporation (“Beckett”) product is warranted to be free from defects in material and workmanship for the applicable Warranty Period (herein so called) set forth below. The
Warranty Period for each product commences on the date of purchase by the original purchaser. The Warranty Periods are as follows:
Product Type or Name
Warranty Period
Product Type or Name
Warranty Period
Pump Models:
Liner Material:
FR Series, DP800-1800, G Series, W Series …………2 Years
35 mil PVC…………………………………..20 Years
UL6500A; XL-6500A………………………. 2 Years
40 mil EPDM………………………...………20 Years
Other Pump Models……………………….. 1 Year
20 mil PVC…………………………………..15 Years
Pre-Formed Poly Ponds………………………..………. 15 Years UV9/UV13 Filter……………………………. 1 Year
Waterfall Weir & Skimmer………………………..……… 5 Years
All Other Beckett Products.……………………………90 Days
APPLICATION: The warranty covers only properly installed and maintained Beckett products and is limited to application at normal temperature 32º F to 212º F, (0º C to 100º C)
pumping fluids with a specific gravity up to 1.1 and with a pH range of 5 to 9 (fresh water). Other liquid applications and extreme temperature uses must be approved in advance by
Beckett. The warranty does not apply to or cover damages or defects caused by external causes, including, but not limited to, improper or faulty installation or unauthorized
modification, lightning, electrical surges, abuse, misuse or abnormal use or misapplication, including use in a manner inconsistent with the product’s intended function. The purchaser is
responsible for determining the suitability of the product for its intended use. If products are damaged in transit, a claim should be filed with the carrier.
REMEDY: If there has been a failure to conform to the warranty, Beckett will, at Beckett’s option, repair, replace or issue a credit or refund for the particular nonconforming product or
part. Repair, replacement, credit or refund, at Beckett’s option, is the exclusive remedy in the event of a failure to conform to the warranty. Warranty claims must be made within 3
months after expiration of the applicable Warranty Period.
ADMINISTRATION: Warranty claims must be made by returning the nonconforming Beckett product, freight prepaid, along with proof of purchase, to: Beckett Corporation, Customer
Service Dept., Irving, Texas, telephone (888) 232-5388. Telephone authorization from Beckett is required prior to returning nonconforming products or parts. All products or parts
returned will be inspected to determine cause of failure before warranty is approved.
INSTALLATION, REMOVAL AND/OR SHIPPING CHARGES: The warranty does not cover any costs associated with the installation, removal or shipping of products subject to
warranty claims.
DISCLAIMER AND LIMITATION: THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND
REMEDIES, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. TO THE FULL EXTENT PERMITTED BY LAW, BECKETT EXPRESSLY DISCLAIMS ANY AND ALL IMPLIED
WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF IMPLIED
WARRANTIES CANNOT BE DISCLAIMED, ALL SUCH IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY.
BECKETT DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES EXPRESSLY SET FORTH IN THIS WARRANTY. IN NO EVENT SHALL BECKETT BE LIABLE OR
RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. BECKETT’S AGGREGATE LIABILITY UNDER THIS WARRANTY OR WITH RESPECT TO ANY PRODUCT
COVERED HEREBY, UNDER ANY LEGAL THEORY, SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE NONCONFORMING PRODUCT. THE LIMITATIONS
CONTAINED IN THIS PARAGRAPH SHALL NOT APPLY TO INJURY TO THE PERSON.
Some States do not allow the exclusion or limitation of incidental or consequential damages or exclusions or limitations on the duration of an implied warranty, so the above limitations or
exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights that vary from State to State.
FOR YOUR RECORDS:
Date of Purchase __________________________________
Model Number __________________________________
Name of Dealer __________________________________
PLEASE KEEP RECEIPT IN CASE OF WARRANTY SERVICE.
MAINTENANCE AND TROUBLE SHOOTING
1.
Remove dirt that may collect in bottom sump.
2.
Look at vinyl DISCHARGE LINE to see that it is open and water can pass through freely.
3.
Always replace cover to keep electrical parts clear of dust and grime.
4.
See item 7 of Introduction.
BECKETT CORPORATION
Irving, Texas
www.beckettpumps.com
Toll Free: 1-888-232-5388
© 2017 BECKETT CORPORATION All Rights Reserved
WIRING
The wiring must comply with local codes.
WARNING
Turn the electric power off at the fuse box before making any line voltage connections.
To test safety float switch, temporarily stop flow of discharge line by sharply bending vinyl tubing. Pour more water into pump
inlet. Water level will rise beyond high level of control float until safety float switch breaks the “Y” thermostat circuit shutting down
air conditioner condensing unit. Unbend the tube and the pump will empty the entire sump. Replace inlet line into pump inlet.
Pump
Micro Switch
Safety Micro Switch
Green Ground
Conn.
Terminal
Block
Voltage as
shown on
Name Plate
Attach to
“Y” on Relay
“Y” on Thermostat
NEC. Class 2
(Low Voltage)
Pump
Black
White
Green
MODELO: CB501ULHTS, CB502ULHTS, CB504ULHTS, CP651ULHTS y CP654ULHTS
NORMAS PARA OPERACIÓN SEGURA
1.
Lea cuidadosamente el Manual del Usuario y las reglas para operación
segura. Si no sigue las reglas de operación segura y las instrucciones,
podría causar lesiones personales o daños a propiedad.
2.
Todo el alambrado debe estar en conformidad con los códigos locales.
Si no existe un código local, use el Código Eléctrico Nacional.
3.
¡PRECAUCIÓN! Para Reducir el riesgo de choque eléctrico, desconecte
el suministro de energía antes de darle servicio. En los modelos que
tienen una conexión de enchufe, desenchúfela.
4.
No maneje la bomba con las manos mojadas o con los pies en agua,
debido a que podría ocurrir un choque eléctrico fatal. ¡Desconecte el
tablero principal antes de manejar la unidad por CUALQUIER RAZÓN!
5.
Proteja El cable de potencia del contacto con objetos filudos.
6.
No doble el cordón de energía y jamás permita que el cable esté
contacto con aceite, grasa, superficies calientes o químicos.
7.
Asegúrese de que la línea esté en conformidad con el voltaje
especificado en el motor y en la placa.
8. ¡ADVERTENCIA! para reducir el riesgo de choque eléctrico, conéctela
solamente a una toma de corriente propiamente conectada a tierra.
INSTALACIÓN
Seleccione un lugar para la bomba. Debe estar lo
más cerca posible al serpentín del aire
acondicionado pero evite cualquier rociado de
agua o gotas sobre o cerca del motor y la cubierta
del interruptor.
La bomba tiene que estar nivelada. El agujero de
entrada de la bomba debe por debajo del nivel de
drenaje del serpentín.
Desempaque la bomba cuidadosamente.
Remueva la cubierta del interruptor. Revise el rotor
de cada flotador para ver si tiene acción libre.
TUBERÍA
Instale una línea de drenaje desde el drenaje del serpentín del
evaporado hasta la bomba. Donde los códigos lo permitan, use
tubería de plástico flexible. Inserte el tubo una pulgada debajo
de la cubierta de la bomba. No instale una línea de drenaje de
entrada que pueda interferir con la operación de los flotadores.
Conecte la tubería de desagüe (ya sea de cobre o de vinilo) al
tubo de descarga de la bomba. No instale la tubería de
desagüe (ya sea de cobre o de vinilo) al tubo de descarga de la
bomba. No instale la tubería verticalmente más de la altura de
impulsión recomendada para cada unidad. Para un buen flujo,
incline el recorrido horizontal un poco hacia el desagüe. Cada
unidad viene típicamente con una válvaula de retención, CU2
para conectar con el tubo de cobre de ½” D.E. Un adaptador
de cobre es incluido para conexiones con tubería de vinilo.
Motor
La Cubierta
El Soporte
Flotador
Tanque
El Interruptor de Seguridad
Interruptor
Primario
El Bloque de Terminal
Tubería de
Vinilo
Evaporador
(Serpentín
en “A”)
Altura de
Impulsión
Indicada
Salida
Tubo del Cobre
Anillo Interno
Tuerca
Válvula de
Cheque
Bola-Jaula
Anillo-Chasquido
Bola
Adaptador
Lea y siga todas las instrucciones de seguridad.
Guarde este manual para referencia en el futuro.
Entrada
BOMBA PARA REMOVER CONDENSACION