Run a drain line from the evaporator coil drain to the pump. Use the flexible plastic pipe where the code permits. Insert the pipe 1” below the pump cover. Do not install inlet drain line that would interfere with operation of floats. Connect outlet tubing (copper or vinyl) to discharge on pump. Do not run tubing vertical more than is recommended by the lift on each unit. For good flow, slant the horizontal run downward toward the drain. Each unit comes standard with a check valve for connecting to ½” O.D. copper tubing. A copper tube adapter is included for vinyl hose hook-up. RULES FOR SAFE OPERATION 1. Carefully read the Owners Manual and rules for safe operation. 2. All wiring must conform to local codes. Use the National Electric Code if local code is nonexistent. 3. CAUTION! To reduce risk of electric shock disconnect from power supply before servicing, pull the plug on models which have plug-in connections. 4. Do not handle the pump with wet hands or when standing in water as fatal shock could occur. Disconnect main power before handling unit for ANY REASON! 5. Protect the power cable from coming in contact with sharp objects. 6. Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces or chemicals. 7. Make certain that line voltage conforms to the voltage specified on motor and nameplate. 8. WARNING! To reduce risk of electrical shock, connect only to a properly grounded grounding type receptacle. INSTALLATION Select a location for the pump. It should be as near as possible to the air conditioning coil but avoid any water spray or drops on or near the motor and switch cover. The pump must be level. The inlet hole must be below the coil drain. Carefully unpack the pump. Remove the switch cover. Check each float rod for “free” action. PIPING COVER PRIMARY SWITCH TERMINAL BLOCK FLOAT TANK STAND OUTLET INLET MOTOR SAFETY SWITCH Designated Pump Lift Copper Tube Vinyl Hose Evaporator (“A” Coil) Inner Ring 92318_RevC MODEL: CB501ULHTS, CB502ULHTS, CB504ULHTS, CP651ULHTS, CP654ULHTS Nut Check Valve Ball-Cage Snap Ring Ball Adapter Read and Follow all Safety Instructions. Save This Manual for Future Reference. CONDENSATE REMOVAL PUMP LIMITED WARRANTY Each Beckett Corporation (“Beckett”) product is warranted to be free from defects in material and workmanship for the applicable Warranty Period (herein so called) set forth below. The Warranty Period for each product commences on the date of purchase by the original purchaser. The Warranty Periods are as follows: Product Type or Name Warranty Period Product Type or Name Warranty Period Pump Models: Liner Material: FR Series, DP800-1800, G Series, W Series …………2 Years 35 mil PVC…………………………………..20 Years UL6500A; XL-6500A………………………. 2 Years 40 mil EPDM………………………...………20 Years Other Pump Models……………………….. 1 Year 20 mil PVC…………………………………..15 Years Pre-Formed Poly Ponds………………………..………. 15 Years UV9/UV13 Filter……………………………. 1 Year Waterfall Weir & Skimmer………………………..……… 5 Years All Other Beckett Products.……………………………90 Days APPLICATION: The warranty covers only properly installed and maintained Beckett products and is limited to application at normal temperature 32º F to 212º F, (0º C to 100º C) pumping fluids with a specific gravity up to 1.1 and with a pH range of 5 to 9 (fresh water). Other liquid applications and extreme temperature uses must be approved in advance by Beckett. The warranty does not apply to or cover damages or defects caused by external causes, including, but not limited to, improper or faulty installation or unauthorized modification, lightning, electrical surges, abuse, misuse or abnormal use or misapplication, including use in a manner inconsistent with the product’s intended function. The purchaser is responsible for determining the suitability of the product for its intended use. If products are damaged in transit, a claim should be filed with the carrier. REMEDY: If there has been a failure to conform to the warranty, Beckett will, at Beckett’s option, repair, replace or issue a credit or refund for the particular nonconforming product or part. Repair, replacement, credit or refund, at Beckett’s option, is the exclusive remedy in the event of a failure to conform to the warranty. Warranty claims must be made within 3 months after expiration of the applicable Warranty Period. ADMINISTRATION: Warranty claims must be made by returning the nonconforming Beckett product, freight prepaid, along with proof of purchase, to: Beckett Corporation, Customer Service Dept., Irving, Texas, telephone (888) 232-5388. Telephone authorization from Beckett is required prior to returning nonconforming products or parts. All products or parts returned will be inspected to determine cause of failure before warranty is approved. INSTALLATION, REMOVAL AND/OR SHIPPING CHARGES: The warranty does not cover any costs associated with the installation, removal or shipping of products subject to warranty claims. DISCLAIMER AND LIMITATION: THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. TO THE FULL EXTENT PERMITTED BY LAW, BECKETT EXPRESSLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF IMPLIED WARRANTIES CANNOT BE DISCLAIMED, ALL SUCH IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY. BECKETT DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES EXPRESSLY SET FORTH IN THIS WARRANTY. IN NO EVENT SHALL BECKETT BE LIABLE OR RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. BECKETT’S AGGREGATE LIABILITY UNDER THIS WARRANTY OR WITH RESPECT TO ANY PRODUCT COVERED HEREBY, UNDER ANY LEGAL THEORY, SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE NONCONFORMING PRODUCT. THE LIMITATIONS CONTAINED IN THIS PARAGRAPH SHALL NOT APPLY TO INJURY TO THE PERSON. Some States do not allow the exclusion or limitation of incidental or consequential damages or exclusions or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights that vary from State to State. FOR YOUR RECORDS: Date of Purchase __________________________________ Model Number __________________________________ Name of Dealer __________________________________ PLEASE KEEP RECEIPT IN CASE OF WARRANTY SERVICE. MAINTENANCE AND TROUBLE SHOOTING 1. Remove dirt that may collect in bottom sump. 2. Look at vinyl DISCHARGE LINE to see that it is open and water can pass through freely. 3. Always replace cover to keep electrical parts clear of dust and grime. 4. See item 7 of Introduction. BECKETT CORPORATION Irving, Texas www.beckettpumps.com Toll Free: 1-888-232-5388 © 2017 BECKETT CORPORATION All Rights Reserved WIRING The wiring must comply with local codes. WARNING Turn the electric power off at the fuse box before making any line voltage connections. To test safety float switch, temporarily stop flow of discharge line by sharply bending vinyl tubing. Pour more water into pump inlet. Water level will rise beyond high level of control float until safety float switch breaks the “Y” thermostat circuit shutting down air conditioner condensing unit. Unbend the tube and the pump will empty the entire sump. Replace inlet line into pump inlet. Pump Micro Switch Safety Micro Switch Green Ground Conn. Terminal Block Voltage as shown on Name Plate Attach to “Y” on Relay “Y” on Thermostat NEC. Class 2 (Low Voltage) Pump Black White Green MODELO: CB501ULHTS, CB502ULHTS, CB504ULHTS, CP651ULHTS y CP654ULHTS NORMAS PARA OPERACIÓN SEGURA 1. Lea cuidadosamente el Manual del Usuario y las reglas para operación segura. Si no sigue las reglas de operación segura y las instrucciones, podría causar lesiones personales o daños a propiedad. 2. Todo el alambrado debe estar en conformidad con los códigos locales. Si no existe un código local, use el Código Eléctrico Nacional. 3. ¡PRECAUCIÓN! Para Reducir el riesgo de choque eléctrico, desconecte el suministro de energía antes de darle servicio. En los modelos que tienen una conexión de enchufe, desenchúfela. 4. No maneje la bomba con las manos mojadas o con los pies en agua, debido a que podría ocurrir un choque eléctrico fatal. ¡Desconecte el tablero principal antes de manejar la unidad por CUALQUIER RAZÓN! 5. Proteja El cable de potencia del contacto con objetos filudos. 6. No doble el cordón de energía y jamás permita que el cable esté contacto con aceite, grasa, superficies calientes o químicos. 7. Asegúrese de que la línea esté en conformidad con el voltaje especificado en el motor y en la placa. 8. ¡ADVERTENCIA! para reducir el riesgo de choque eléctrico, conéctela solamente a una toma de corriente propiamente conectada a tierra. INSTALACIÓN Seleccione un lugar para la bomba. Debe estar lo más cerca posible al serpentín del aire acondicionado pero evite cualquier rociado de agua o gotas sobre o cerca del motor y la cubierta del interruptor. La bomba tiene que estar nivelada. El agujero de entrada de la bomba debe por debajo del nivel de drenaje del serpentín. Desempaque la bomba cuidadosamente. Remueva la cubierta del interruptor. Revise el rotor de cada flotador para ver si tiene acción libre. TUBERÍA Instale una línea de drenaje desde el drenaje del serpentín del evaporado hasta la bomba. Donde los códigos lo permitan, use tubería de plástico flexible. Inserte el tubo una pulgada debajo de la cubierta de la bomba. No instale una línea de drenaje de entrada que pueda interferir con la operación de los flotadores. Conecte la tubería de desagüe (ya sea de cobre o de vinilo) al tubo de descarga de la bomba. No instale la tubería de desagüe (ya sea de cobre o de vinilo) al tubo de descarga de la bomba. No instale la tubería verticalmente más de la altura de impulsión recomendada para cada unidad. Para un buen flujo, incline el recorrido horizontal un poco hacia el desagüe. Cada unidad viene típicamente con una válvaula de retención, CU2 para conectar con el tubo de cobre de ½” D.E. Un adaptador de cobre es incluido para conexiones con tubería de vinilo. Motor La Cubierta El Soporte Flotador Tanque El Interruptor de Seguridad Interruptor Primario El Bloque de Terminal Tubería de Vinilo Evaporador (Serpentín en “A”) Altura de Impulsión Indicada Salida Tubo del Cobre Anillo Interno Tuerca Válvula de Cheque Bola-Jaula Anillo-Chasquido Bola Adaptador Lea y siga todas las instrucciones de seguridad. Guarde este manual para referencia en el futuro. Entrada BOMBA PARA REMOVER CONDENSACION