Installation manual [PDF] (16 pages)
- Updated: 30.06.2026
Document Preview & Text Transcription
Ultraview US23-0640-09
07-30-09
V4
© Copyright 2009 Besam US Inc. May not be reprinted without permission
1
Complies with ANSI/BHMA A156.10 Standard for Power Operated Pedestrian Doors. UL325 Listed
Besam UltraView
Installation Manual
AAE977
Contents
Important Information
Technical Specifications
Component Identification
Electrical Installation
Initial Sensor Setup
Mechanical Adjustments
Remote Control
1-Way Traffic Setup
Manual Setup
Troubleshooting
Retrofit Installation
Standard Inputs vs. Auxiliary Inputs
The Ultraview combines k-band microwave and focused active infrared technology to
provide superior activation and safety for the Unislide door system. For activation, the
unit provides digitally processed and sophisticated motion tracking technology for
unidirectional sensing when energy conservation is critical. For safety, the unit emits two
rows of 24 beams of focused presence technology that provides extraordinary safety in
and around the threshold Area. The active infrared curtains never shut off, even during
closing. Thus providing superior detection performance.
SPECIAL NOTE: The Ultraivew works differently than the BEA Wizard...
When making changes to the Ultraview reference the Ultraview users guide.
If you inadvertently make changes based on the BEA Wizard, you will cause
problems within the Ultraview system, which will result in callbacks.
Important notice!
To avoid bodily injury, material damage and malfunction of the product, the
instructions contained in this manual must be strictly observed.
Note!
Instructions, design, specifications and illustrations that are contained in
this manual are not binding. Rights reserved for changes without previous notice.
Environment
This operator may be equipped with batteries containing materials that are
hazardous to the environment. Remove the batteries from the operator before it
is scrapped. The batteries must be disposed of safely.
2
3
4
4
5-6
6
7-8
9
10
11
12-13
13
Product Overview
Important Information
Ultraview US23-0640-09
07-30-09
V4
© Copyright 2009 Besam US Inc. May not be reprinted without permission
2
Motion Sensor
Presence Sensor
Technical Specifications
Description
Spe cification
Supply voltage
12 to 24 VDC: -5% to + 10%
Power consumption
<125 mA @24 VDC per sensor
Mounting height:
Standard
High
5’9” to 8’2” (1753 mm to 2489 mm)
8’2” to 13’ (2489 mm to 3962 mm)
Output
Motion Sensor
Optocoupled Transistor (Activation)
Max output current: 200 mA
Max switching power:48 VDC
Hold time 0.5 sec (fixed)
Presence Sensor
Optocoupled Transistor (Safety)
Max output current: 200 mA
Max switching voltage:48 VDC
Hold time 1 sec (fixed)
Monitoring
P1: Test (0V)
P2: C-Switch
3-color LED
GREEN
: motion detection
RED
: presence detection
ORANGE : monitoring / error code
Temperature range
-30°F to +131°F (-34° C to + 55° C)
Degree of protection
NEMA 3S / (IP54)
Sensor dimension (exposed)
11.9” (302mm) L x 1.9” (48mm) W x 0.9”
(24mm) D
Weight
0.55 lbs / 250 g
Housing material
ABS & LURAN S
Cable description:
Quick-disconnect Harness (sensor)
Short Extension Harness (black)
Long Extension Harness (gray)
1’ (300 mm), plug and play, 10-conductor
6’ (1530 mm), plug and play, 10-conductor
16’ (4580 mm), plug and play, 10-conductor
Product conformity
R&TTE 1999/5/EC & EMC 89/336/EEC, FCC
Interface
Factory Installed
Technology
Microwave and microprocessor
Transmitter frequency: 24.125 GHz
Transmitter radiated power: <20 dBm EIRP
Transmitter power density: < 5 mW/cm²
Focused active infrared with background track-
ing and self-monitored microprocessor
Spot diameter (standard) : 4” max
Number of spots : 24 or 12 spots by curtain
Number of curtains : 2
Detection field at 7’ (2130mm) mount height
Wide field
Narrow field
13’0” W x 6’6” D (3962 mm W x 1981 mm D)
6’6” W x 8’2” D (1981mm W x 2489 mm D)
6’6” W x 13.75” D (1981mm W x 349 mm D)
3’3” W x 13.75” D (991 mm W x 349 mm D)
Detection mode
Minimum detection speed
2 inches / sec. (measured in the sensor axis)
Response time : < 128ms
Angular adjustments
from 15° to 45° in elevation (adjustable)
from - 4° to + 4° (adjustable)
Manual adjustment
Orientation of sensing field (mechanically)
Shape of the sensing field (choice of antenna)
Multiple functions (using push buttons).
Orientation of sensing field
Shape of the sensing field (choice of lens)
Multiple functions (using push buttons).
Remote control adjustments
Sensitivity
Detection mode
Immunity
Sensitivity
Auto-learn time
Ultraview US23-0640-09
07-30-09
V4
© Copyright 2009 Besam US Inc. May not be reprinted without permission
3
Component Identification
Electrical Installation
Connect the Extension Harnesses to the Ultraview Interface Board at the control as follows:
1. Designate the sensors as P1 or P2.
Important: The side of the door “not intended for use” when door is in one-way mode will be
designated P2.
2. The longer extension harness has a gray jacket and will be connected to the sensor on the
plank side. The shorter extension harness has a black jacket and is connected to the header
access side. Based on Step 1, connect the appropriate extension harness to the appropriate
connector on the Ultraview Interface Board.
Ultraview US23-0640-09
07-30-09
V4
© Copyright 2009 Besam US Inc. May not be reprinted without permission
4
MOUNTING SCREWS
INFRARED LENS
SHROUD
SENSOR
COVER
ULTRAVIEW
INTERFACE BOARD
QUICK DISCONNECT HARNESS(2 per system)
SHORT (black)
EXTENSION HARNESS
LONG (gray)
EXTENSION HARNESS
WIDE IR US21-0640-07
NARROW IR US21-0640-08
US02-0640-01
US21-0640-06
US02-0640-02
US02-0640-05
DIP SWITCH
STOP/IMPULSE(BREAKOUT INPUT)
P2
P1
STD/AUX SWITCH
KNOWING ACT INPUT (AUX)
US02-0640-04
US02-0640-03
Ultraview Replacement Sensor Kit - US15-0640-14
One assembled unit consisting of sensor, shroud, cover, wide lens, narrow lens,
mounting screws and quick disconnect harness.
(Not available as a spare part)
(Not available as a spare part)
Pages Preview: