BLAUBERG Ventilatoren KOMFORT EC S 160 Manuals

1 pdf manual(s) BLAUBERG Ventilatoren KOMFORT EC S 160 for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

Air hAndling unit USER’S MANUAL EN KOMFORT EC S 160 KOMFORT EC S 160-E KOMFORT EC S1 160 KOMFORT EC S1 160-E KOMFORT EC SB 160 KOMFORT EC S1B 160 KOMFORT EC SB 160-E KOMFORT EC S1B 160-E KOMFORT EC SB 350 KOMFORT EC S1B 350 KOMFORT EC SB 350-E KOMFORT EC S1B 350-E KOMFORT EC SB 550 KOMFORT EC SB 550-E This user’s manual is a main operating document intended for technical, maintenance, and operating staff. The manual contains information about the purpose, technical details, operating principle, design, and installation of the KOMFORT EC S(1)(B) 160/350/550(-E) unit (-s) and all of its (their) modifications. Technical and maintenance staff must have theoretical and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country. The information in this user’s manual is correct at the time of the document’s preparation. The Company reserves the right to modify the technical characteristics, design, or configuration of its products at any time in order to incorporate the latest technological developments. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means in any information search system or translated into any language in any form without the prior written permission of the Company. CONTENTS Safety requirements .....................................................................................................................................................................2 Purpose ................................................................................................................................................................................................4 Delivery set ........................................................................................................................................................................................4 Designation key ..............................................................................................................................................................................4 Technical data ..................................................................................................................................................................................5 Design and operating principle ...........................................................................................................................................7 Installation and set-up................................................................................................................................................................9 Connection to power mains ..................................................................................................................................................12 Technical maintenance ..............................................................................................................................................................15 Storage and transportation regulations ..........................................................................................................................16 Possible reasons and troubleshooting .............................................................................................................................16 Manufacturer’s warranty ...........................................................................................................................................................17 Certificate of acceptance ..........................................................................................................................................................19 Seller information ..........................................................................................................................................................................19 Installation certificate ..................................................................................................................................................................19 Warranty card ...................................................................................................................................................................................19 SAFETY REQUIREMENTS All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical norms and standards must be observed when installing and operating the unit. Disconnect the unit from power supply prior to any connection, servicing, maintenance, and repair operations. Only qualified electricians with a work permit for electrical units up to 1000 V are allowed for installation and maintenance. The present user’s manual should be carefully read before beginning works. • Single-phase power mains must comply with the acting local electrical norms and standards. • Fixed electrical wiring must be equipped with an automatic circuit breaker. • The unit must be connected to power mains through a double pole circuit breaker of suitable rating integrated into the fixed wiring system with opening of contacts at all poles. The gap between the circuit breaker contacts at all poles must be not less than 3 mm. • Check the unit for any visible damage of the impeller, the casing, and the grille before starting installation. The casing internals must be free of any foreign objects that can damage the impeller blades. www.blaubergventilatoren.de KOMFOrt EC S(1)(B) 160/350/550(-E) 2 THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE. DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE. • While mounting the unit, avoid compression of the casing! Deformation of the casing may result in motor jam and excessive noise. • Misuse of the unit and any unauthorized modifications are not allowed. • Do not expose the device to adverse atmospheric agents (rain, sun, etc.). • Take steps to prevent ingress of smoke, carbon monoxide, and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. • The unit may adversely affect the safe operation of appliances burning gas or other fuels (including those in other rooms) due to back flow of combustion gases. These gases can potentially result in carbon monoxide poisoning. After installation of the unit the operation of flued gas appliances should be tested by a competent person to ensure that back flow of combustion gases does not occur. • Transported air must not contain any dust or other solid impurities, sticky substances, or fibrous materials. • Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, insecticides, etc. • Do not close or block the intake or extract vents in order to ensure the efficient air flow. • Do not sit on the unit and do not put objects on it. • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. • Do not allow children to play with the unit. • Cleaning and user maintenance shall not be made by children without supervision. • The information in this user’s manual was correct at the time of the document’s preparation. • The Company reserves the right to modify the technical characteristics, design, or configuration of its products at any time in order to incorporate the latest technological developments. • No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means in any information search system or translated into any language in any form without the prior written permission of the Company. WARNING! Similar to the use of any other household electrical appliances when operating this fan, the following basic rules must be followed: • Never touch the fan with wet or damp hands. • Never touch the fan when barefoot. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent. www.blaubergventilatoren.de KOMFOrt EC S(1)(B) 160/350/550(-E) 3 DELIVERY SET DESIGNATION KEY Name Number Air handling unit 1 pc. User's manual 1 pc. Control panel 1 pc. Packing box 1 pc. *Control panel is not included in delivery set of units equipped with S21 controller. PURPOSE The unit is designed to ensure continuous mechanical air exchange in houses, offices, hotels, cafes, conference halls, and other utility and public spaces as well as to recover the heat energy contained in the air extracted from the premises to warm up the filtered stream of intake air. The unit is not intended for organizing ventilation in swimming pools, saunas, greenhouses, summer gardens, and other spaces with high humidity. Due to the ability to save heating energy by means of energy recovery, the unit is an important element of energy-efficient premises. The unit is a component part and is not designed for stand-alone operation. It is rated for continuous operation. Transported air must not contain any flammable or explosive mixtures, evaporation of chemicals, sticky substances, fibrous materials, coarse dust, soot and oil particles or environments favourable for the formation of hazardous substances (toxic substances, dust, pathogenic germs). www.blaubergventilatoren.de KOMFOrt EC S(1)(B) 160/350/550(-E) 4 KOMFORT EC S 1 B 160 E S21 Control S14 S21 Heat exchanger type _: heat recovery air handling unit E: energy recovery air handling unit Rated air flow [m3/h] Extra components _: no additional components B: bypass Casing design Spigot orientation S: vertical spigot orientation Motor type EC: electronically commutated Series