Bticino PIVOT Manuals

2 pdf manual(s) Bticino PIVOT for free download (Document Types: Technical data, Operation & user’s manual)

Bticino PIVOT Technical data Main Page Preview

Technical data [PDF] (2 pages)

  • Updated: 31.05.2026

Document Preview & Text Transcription

1 68,5 mm 210 mm 210 mm 6 5 4 1 2 8 3 7 OFF ON 5 BUS 1 ET 2 1 N P 9 10 11 12 344122 14/10/2013 BT00652-a- Dimensional data Description 2 WIRE PIVOT video handset for wall mounted, flush mounted, or table top installation. TFT colour 4” flat monitor. It has door lock release, staircase light, and entrance panel activation keys. The device offers the possibility of selecting among 16 already programmed bells for floor call, main entrance panel, intercom call, and secondary entrance panel. The call volume can be set on three levels: high, medium and disabled (this condition is signalled by a flashing red LED). It also has a call secrecy function. It is connected to the system using the removable clamp supplied. Wall mounting bracket supplied as standard. Technical data Power supply from SCS BUS: 18 – 27 Vdc Stand by absorption: 5 mA Max. operating absorption: 290 mA Operating temperature: 5 - 40°C Related items 346812 4 key small block for auxiliary functions - white 337122 table-top support - white NOTE: for flush mounted installation refer to the specific accessories of the MULTIBOX range. PIVOT colour video handset Legend 1. 4” TFT colour monitor 2. Monitor colour, contrast, and brightness adjustment 3. Extensible cord capped on both ends with RJ connectors 4. Door lock key 5. Staircase light key 6. Entrance panel activation/cycling 7. Electronic call with volume adjustable on 3 levels: high, medium, disabled (the excluded call is signalled by a flashing red LED) 8. 4-key block housing (optional) 9. Line termination ON/OFF micro-switch 10. Configurator socket 11. MASTER-SLAVE Jumper (remove to enable SLAVE) 12. Plug-in clamp for the connection of the 2 WIRE BUS, additional power supply, and auxiliary floor call function, as well as extra bell. 2 WIRE Video Door Entry system EN 2 SLAVE N P 1 MASTER N P 1 SLAVE N P 1 MASTER N P 1 4 1 1 16 2 RESET 1 16 2 RESET 1 16 2 RESET 1 16 2 RESET OK OK OK OK 2 4 3 1 2 4 3 1 2 4 3 1 2 4 3 1 4 1 1 16 2 RESET 1 16 2 RESET 1 16 2 RESET 1 16 2 RESET OK OK OK OK 2 4 3 1 2 4 3 1 2 4 3 1 2 4 3 1 4 1 1 16 2 RESET 1 16 2 RESET 1 16 2 RESET 1 16 2 RESET OK OK OK OK 2 4 3 1 2 4 3 1 2 4 3 1 2 4 3 1 4 1 1 16 2 RESET 1 16 2 RESET 1 16 2 RESET OK OK 2 4 3 1 2 4 3 1 2 4 3 1 344122 14/10/2013 BT00652-a- Configuration N – handset number The N configurator assigns each video handset an identification number within the system. The handsets must be configured in progressive order. The handsets must be configured in progressive order.Handsets with parallel connection (max 3 are allowed inside apartments without 346850) must be configured using the same N configurator. In parallel with the main video handset, additional handsets, video handsets and/or bells may be installed. P – entrance panel association The P configurator identifies the entrance panel associated, or the first entrance panel to activate before pressing the key and which door lock is activated when the key is pressed while the video handset is idle. Connected jumper Disconnected jumper MASTER – SLAVE selection jumper In multi-family systems with several video handsets (max. 3) connected in parallel inside the same apartment (without using 346850), both the MASTER and the SLAVE handsets must be set, by connecting or removing the selection jumper. When a call is received, the MASTER video handset of the system rings and switches on, while the video handsets configured as SLAVE only rings. If the call is answered from a SLAVE unit, the MASTER unit switches off again, while the monitor of the SLAVE unit the call has been answered from comes on. When a pushbutton of SLAVE unit is pressed before answering, the MASTER handset monitor switches off, while the monitor of SLAVE on which the pushbutton has been pressed switches on, but without audio connection. Bell selection from MAIN ENTRANCE PANEL (S=0 - S=4) FLOOR CALL bell selection Bell selection from SECONDARY ENTRANCE PANEL (S=0 - S=5) INTERCOM CALL bell selection Programming of bells PIVOT colour video handset EN

Document Preview & Text Transcription

1 BT00653-a 346812 1 2 3 4 1 2 3 4 1 2 3 4 MOD -EN TECHNICAL SHEETS Description 4 key accessory for handsets item 344032, and video handsets item 344102, 344122, . It must be installed inside the handset, in the preset location. It can be used to perform the listed functions, based on the type of configuration set: - Intercom call among various system devices and apartments (max. 5) - control of actuators for additional door locks - control of actuators for general uses and auto-switching on of the entrance panel - mixed activations - paging function through the 2 WIRE sound system - enabling/disabling of home automation scenarios - apartment intercom in two-family system Legend 1 - Key 1 2 - Key 2 3 - Key 3 4 - Key 4 PIVOT 4 key handset accessory Configuration Configuration The device must be configured fisicamente per stabilirne la operating mode: M - Operating mode It sets the operating mode allocated to the individual keys of the accessory block. The mode changes depending on whether the apartment interface, item 346850, has been installed or not. MODE FUNCTION OF KEYS WITHOUT item 346850 FOR MULTI-FAMILY SYSTEMS WITHIN THE APARTMENT WITH item 346850 MOD= Direct switching on of the EPs Direct switching on of the EPs configured with P+1 Direct switching on of the EPs configured with P+2 Direct switching on of the EPs configured with P+3 Direct switching on of the EPs configured with P+4 Control of the actuator for generic loads (Item 346200) 346200 configured with MOD=9 and P=P+1 346200 configured with MOD=9 and P=P+2 346200 configured with MOD=9 and P=P+3 346200 configured with MOD=9 and P=P+4 MOD= 1 Intercom among the apartment with N-1-5 Intercom among Handsets with N=1-5 MOD= 2 Intercom among apartments with interface item 346850 – N=1-4 Intercom among apartments configured with N=1-4 4 3 2 1 4 3 2 1 Selection of MOD configurators 2 BT00653-a 346812 -EN TECHNICAL SHEETS Configuration Selection of MOD configurators MODE FUNCTION OF KEYS WITHOUT item 346850 FOR MULTI-FAMILY SYSTEMS WITHIN THE APARTMENT WITH item 346850 MOD = 3 1 Auto-switching on of EPs configured with P+1 1 Auto-switching on of local entrance panels 2 Door lock control for EPs configured with P+1 2 Door lock control for the local EP (direct mode) Keys 3 and 4 for intercom among the handsets Keys 3 and 4 for intercom among the handsets of the of different apartments config. with N=1-3 apartment configured with N=1-3 MOD = 5 Control of door lock relay with: Actuator for generic loads (Item 346200) 1 346200 configured with MOD=5 and P=P+1 2 346200 configured with MOD=5 and P=P+2 3 346200 configured with MOD=5 and P=P+3 4 346200 configured with MOD=5 and P=P+4 Door lock actuator (Item 346230 - Item 346260) 1 Actuator configured with P=1 2 Actuator configured with P=2 3 Actuator configured with P=3 4 Actuator configured with P=4 MOD = 6 Keys 1 , 2 and 3 for intercom among handsets configured with N=1 - 4 4 Paging function MOD = 7 1 Intercom among apart. devices (general call) (two-family 2 Intercom with devices of other apart. (general call) installations) 3 Door lock control for EPs config. with P+1 Door lock control for EPs config. with P+2 MOD = 7 1 Intercom within the same apartment (multy-family 2 NOT USED installations 3 Door lock control for EPs config. with P+1 config. with N = 3) 4 Door lock control for EPs config. with P+2 MOD = 9 Scenario central unit control (Item F420) A=0 and PL=1 1 Activate scenario 1 2 Activate scenario 2 3 Activate scenario 3 4 Activate scenario 4 3 PS BUS TK BUS PI 2 1 4 3 6 5 8 7 NC NO C 2 2 2 1 2 3 4 O 1 346830 2 1 4 3 6 5 8 7 NC NO C 2 2 1 4 3 6 5 8 7 NC NO C 3 2 1 4 3 6 5 8 7 NC NO C 4 BUS 2 1 346000 230V a.c. 230V a.c. 230V a.c. 230V a.c. BUS MOD=0 346200 346200 346200 MOD=9 P=1 MOD=9 P=3 MOD=9 P=4 PE principale Alimentatore 346200 MOD=9 P=2 230V a.c. BUS BUS 230V a.c. PS BUS TK BUS PI 2 2 2 1 2 3 4 1 346830 2 1 4 3 6 5 8 7 NC NO C 230V a.c. 2 2 1 4 3 6 5 8 7 NC NO C 230V a.c. 3 2 1 4 3 6 5 8 7 NC NO C 230V a.c. 4 BUS 2 1 2 O 346000 BUS MOD=0 346200 346200 346200 MOD=9 P=2 MOD=9 P=3 MOD=9 P=4 BUS BUS P=0 P=1 PE principale PE secondario (P+1) Alimentatore 346812 BT00653-a-EN TECHNICAL SHEETS Configuration Example 1 - MOD = 0 Activation of general use actuators Direct auto-switching on of the second entrance panel and activation of general use actuators