Carel CloudGate Manuals

3 pdf manual(s) Carel CloudGate for free download (Document Types: Assembly instruction manual, Assembly procedure, Assembly procedures)

Carel CloudGate Assembly instruction manual Thumbnail

Carel CloudGate Assembly instruction manual [PDF] (12 pages)

  • Identifier: id-2237704
  • Brand: Carel
  • Device: Carel CloudGate Gateway
  • Type: Assembly instruction manual, PDF
  • Key Aspects: Efficiency and Calibration Tips, Risk Mitigation and Accident Prevention, Detailed Installation Instructions
  • UPD Date: 24.07.2026
  • Source File: 2049928.pdf
  • Pages: 12
  • Description: Installation guide for the Carel CloudGate.
Pages Preview:
  • Carel CloudGate Assembly instruction manual preview - page 2
  • Carel CloudGate Assembly instruction manual preview - page 3
  • Carel CloudGate Assembly instruction manual preview - page 4
  • Carel CloudGate Assembly instruction manual preview - page 5
  • Carel CloudGate Assembly instruction manual preview - page 6
  • Carel CloudGate Assembly instruction manual preview - page 7
  • Carel CloudGate Assembly instruction manual preview - page 8
  • Carel CloudGate Assembly instruction manual preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT! TECHNICAL LEAFLET Cloudgate +0500151ML Up to date version available on www.carel.com Cloudgate Electrical panel assembly instruction
Carel CloudGate Assembly procedure Thumbnail

Carel CloudGate Assembly procedure [PDF] (2 pages)

  • Identifier: id-1910952
  • Brand: Carel
  • Device: Carel CloudGate Gateway
  • Type: Assembly procedure, PDF
  • Key Aspects: Device Specifications Overview, Standard Operating Procedures, Risk Mitigation and Accident Prevention
  • UPD Date: 26.07.2026
  • Source File: 1811808.pdf
  • Pages: 2
  • Description: Manual for installation and usage of the Carel CloudGate.
Pages Preview:
  • Carel CloudGate Assembly procedure preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
G G0 2 24V~/24V 20VA/9W LAN FIELD 6 7 9 11 13 8 1 10 12 4 2 5 3 IP A C D B A C D B E 70 60 110 45 IP KONEKTÖR AÇIKLAMASI / CONNECTOR’S DESCRIPTION düğme / key: Tanım Description 1 Güç kaynağı konektörü [G(+), G0(-)] 24Vac/Vdc Power supply connector [G(+), G0(-)] 24Vac/Vdc 2 LED güç açık lambası (yeşil) / LED power-on (green) 3 Ethernet sinyali Led lambası / Ethernet signal Led 4 Geçici IP etkinleştir / WPS / buluta bağlantı kontrolü (yalnızca 2G/4G mod.için) Enable temporary IP / WPS / connection check to cloud (only for 2G/4G mod.) 5 USB standart HOST Port, A tipi konektör, FW yükseltiliyor ve log dosyaları indiriliyor USB standard HOST Port, type A connector, upgrading FW and log files downloading 6 RS485 seri opto izole / RS485 serial opto-isolated; 7 RS485 seri opto izole değil / RS485 serial not opto-isolated; 8 FIELD Ethernet / FIELD Ethernet; 9 LAN Ethernet / LAN Ethernet; 10 Korumalı ethernet portu toprak bağlantısı için Faston terminal / Faston for shield ethernet port earth connection 11 2G/4G Konektör anteni / 2G/4G Antenna connector (*) 12 Wi-Fi Konektör anteni / Wi-Fi Antenna connector (*) 13 LED sinoptiği / LED synoptic (*)İki Wi-Fi ve 2G/4G seçeneği biri diğerine alternatif olarak mevcuttur / The two options Wi-Fi and 2G / 4G are available as an alternative to the other LED LAMBALARIN ANLAMLARI / LEDS MEANINGS Ethernet versiyonu / Ethernet version Tanım Description A Bulut bağlantısı / Cloud connection B IP adresi atandı / IP address assigned C Ethernet bağlantısı / Ethernet connection D Yazılım motoru: yanıp sönüyor: yükleniyor; sabit: işliyor Software engine: flashing: loading; steady: functioning CloudGate Mobile (wi-fi veya 2G/4G) vers. / CloudGate Mobile (wi-fi or 2G/4G) vers. Tanım Description A Bulut bağlantısı / Cloud connection B IP adresi atandı / IP address assigned C Radyo bağlantısı / Radio connection D Yazılım motoru: yanıp sönüyor: yükleniyor; sabit: işliyor Software engine: flashing: loading; steady: functioning E Radyo bağlantısı gücü: yeşil Led: 2G/4G; sarı Led: Wi-Fi Radio signal strength: green Led: 2G/4G; yellow Led: Wi-Fi BOYUTLARI / DIMENSIONS DIN montajı: DIN 43880 ve IEC EN 50022’e göre DIN ray üzerine kurulur; DIN mounting: fitted on DIN rail in accordance with DIN 43880 and IEC EN 50022; "CloudGate" +0500150TR - rel. 1.1 - 20.10.2020 CloudGate: Montaj prosedürü / Assembly procedure UYARI Bu cihaz, yalnızca, uygun teknik bilgi ve tecrübeye sahip olan ve cihazın hatalı şekilde konfigüre edilmesi halinde maruz kalacakları tehlikelerin farkında olan teknik personel tarafından monte edilmelidir. GENEL NOT Herhangi bir işlem gerçekleştirmeden önce, CloudGate’in aşağıdakileri içerdiğini denetleyin: 1. cihazın kendisi; 2. kablosuz model için: bir anten ( Wi-Fi veya 2G/4G tipi); 3. teknik belgeler; 4. uçbirimler kiti ve seri hat sonu için iki adet 120Ω direnç. Ürünleri aşağıda belirtilen özellikleri taşıyan ortamlara kurmayın: • teknik şartnamelerde belirtilen değerden fazla bağıl nem; • kuvvetli titreşimler veya vurmalar; • korozyon ve/veya oksidasyonu önlemek için agresif ve kirletici atmosferlere (örn: sülfür ve amonyak dumanları, tuz buharları, duman) maruz kalma; • güçlü manyetik ve/veya radyo frekansı enterferansı (bu nedenle üniteleri iletken antenlerin yakınına kurmaktan kaçının); • doğrudan güneş ışığına veya genel olarak öğelere maruz kalma; • oda sıcaklığında geniş ve hızlı dalgalanmalar; • patlayıcıların veya alev alır gaz karışımlarının bulunduğu ortamlar. Radyo modelleri için kurulum uyarıları • Ürünün kurulumunu yapmadan önce, eğer kullanılacak model radyo bağlantısı içeriyorsa, alanı yeterli seviyede 2G/4G - Wi-Fi sinyalinin kapsadığından emin olun; • anteni metal donanımın dışına yerleştirin. TEKNIK ŞARTNAMELER Güç kaynağı G’den G0’a: 24 Vac +%10/-%15 50/60 Hz, 24 Vdc +%5 /-%5 Giriş gücü 9W Maks İşleme koşulları -40T60 °C, %90 B.N. yoğuşmasız Depolama koşulları -40T70 °C, %90 B.N. yoğuşmasız Seri Portlar 1 RS485 Master opto izole- 1 RS485 Master opto izole değil Pil (iç) Lityum “düğme” tipi, BR2032, 3 Vdc, Şarj EDİLMEZ Belgelendirme koşulları KIRMIZI: - WIFI - 2G/4G EN 301 489-1 EN 301 489-17 Ver. 3.1.1 - EN 300 328 Ver. 2.1.1 EN 301 489-52 Ver. 1.1.0 - EN 301 511 Ver. 12.5.1 - EN 301 908-1 Ver. 11.1.1 FCC: - WIFI+2G/4G FCC Bölüm 15 Alt bölüm B, ICES003 FCC Bölüm 15.31 (k) - ANSI C95.1. MPE - RSS-102. MPE Güvenlik: 60950; 62368 ANATEL Bu cihaz zararlı enterferanslara karşı korumaya yetkili değildir ve tam yetkili sistemlerde enterferansa neden olmaz. Boyutları 4 DIN modülü = 70x110x60 mm Kirlilik derecesi EN60950-1 / En62368-1’e göre 2 Koruma indeksi IP10 Kasa malzemesi teknopolimer Cihazın güç beslemesi açık iken cihazı açmayın. Güç kaynağı • Ürünün güç beslemesi yalnızca G ile G0 arasında bağlanmalıdır • Maksimum uzunluk =5 m. • Eğer AC güç beslemesi etkin ise, ikincisinin topraklama bağlantısı olmak zorunda olmadan kısa devrelere ve aşırı akıma karşı korumalı 2 24Vac, 20...30VA Sınıfı bir özel güvenlik transformatörü kullanın. • Eğer doğrudan akım güç beslemesi etkin ise PGTA00TRX0 güç kaynağı kullanın, 100/230Vac-24Vdc (10W ±%2 1 DIN-modülü, Minimum Sıcaklık = -25°C). Pozitif kutbu G’ye ve negatif kutbu G0’a bağlayın. DİKKAT: seri bağlantılar ve güç beslemesi için ayrı kablolar kulllanın. İLETİŞİM HATLARI RS485 iletişim hatları Maksimum uzunluk 1000m’nin üstünde olmamalıdır, AWG24 kılıflı kablo ile, GND’ye değil toprağa ekran bağlantısı ile olmalıdır. Ağın ilk ve son cihazlarına 1/4W olmak üzere, 120Ω uçbirim dirençleri, uzunluk 100 metreyi aşsa bile bağlanmalıdır. Ürüne dahil olan dirençler seri + ve - uçbirimleri arasına bağlanmalıdır: • kutupluluğu izleyin (+.-,GND); • hatta dallanmalar veya yıldız bağlantılar gerçekleştirmeyin; • hattı güç kablolarının yanına döşemekten kaçının. Kontrol cihazının elektromanyetik gürültüye karşı olan bağışıklığını iyileştirmek için, seri bağlantı kablosu korumalı bükümlü çift kablo tipi, seri bağlantının izolasyonuna bağlı olarak iki veya üç bükümlü telli olabilir. Aşağıdaki kural şu durumlarda geçerli olur: • eğer seri port güç beslemesinden yalıtılmış (işlevsel olarak) ise, kontrol cihazları için ortak bir referans rolünü gerçekleştirmek üzere üçüncü bir tel gereklidir; • Eğer seri port optik olarak izole değilse ve ortak referans zaten varsa, üçüncü tele gerek olmaz. RJ45 Ethernet Hattı 100 m Cat.5e SFTP ekranlı kabloları kullanın. Ekran ethernet kablosunun toprak bağlantısını (işlevsel bağlantı) yapmak için, şekilde gösterdiği gibi dişi bir Faston 6,3mm terminal kullanın. Ürün II. Sınıf kategorisindedir, ancak kablo ekranının toprak bağlantısı (işlevsel) için bir faston terminal vardır. Bağlantı, bir koruyucu toprak bağlantısına yönlendirilebilir veya, gerekirse, diğer harici güç kaynakları tarafından beslenen tehlikeli gerilimlerden ayrılmış bir işlevsel toprak bağlantısına yönlendirilebilir. WARNING This appliance must only be installed by service personnel with suitable technical training and experience and who are aware of the dangers they may be exposed to in the event of incorrect configuration (qualified installers). GENERAL NOTE Before performing any operations, check that the CloudGate contains: 1. the device itself; 2. for wireless version: an antenna ( Wi-Fi or 2G/4G type); 3. technical documents; 4. terminals kit and two resistors 120Ω for the end of the serial line. Do not install products in environments with the following characteristics: • relative humidity greater than the value specified in the technical specifications; • strong vibrations or knocks; • exposure to aggressive and polluting atmospheres (e.g.: sulphur and ammonia fumes, saline mist, smoke) so as to avoid corrosion and/or oxidation; • strong magnetic and/or radio frequency interference (therefore avoid installing the units near transmitting antennae); • exposure to direct sunlight and to the elements in general; • large and rapid fluctuations in the room temperature; • environments where explosives or mixes of flammable gases are present. Installation warnings for Radio models • Before installing the product make sure the area is sufficiently covered by a 2G/4G - Wi-Fi signal, if the model to be used includes radio connectivity; • locate the antenna outside metal hardware. TECHNICAL SPECIFICATIONS Power supply from G to G0: 24 Vac +10%/-15% 50/60 Hz, 24 Vdc +5% /-5% Input power 9W Max Operating conditions -40T60 °C, 90% U.R. non-condensing Storage conditions -40T70 °C, 90% U.R. non-condensing Serial Ports 1 RS485 Master opto-isolated- 1 RS485 Master non opto-isolated Battery (internal) Lithium “button” type, BR2032, 3 Vdc, NON rechargeable Certification requirements RED: - WIFI - 2G/4G EN 301 489-1 EN 301 489-17 Ver. 3.1.1 - EN 300 328 Ver. 2.1.1 EN 301 489-52 Ver. 1.1.0 - EN 301 511 Ver. 12.5.1 - EN 301 908-1 Ver. 11.1.1 FCC: - WIFI+2G/4G FCC Part 15 Subpart B, ICES003 FCC Part 15.31 (k) - ANSI C95.1. MPE - RSS-102. MPE Safety: 60950; 62368 ANATEL This equipment is not entitled to protection against harmful interference and may not cause interference in duly authorized systems. Dimensions 4 DIN module = 70x110x60 mm Pollution degree 2 according to EN60950-1 / EN62368-1 Index of protection IP10 Case material tecnopolymer Do not open the device when powered. Power supply • Power supply to the product must only be connected between G and G0 • Maximum length =5 m. • If AC powered, use a dedicated safety transformer rated in Class 2 24Vac, 20...30VA, protected against short-circuits and overload, without secondary must be earthed connected. • If direct current powered use PGTA00TRX0 power supply, 100/230Vac- 24Vdc (10W ±2% 1 DIN-module, Minimum Temperature = -25°C). Connect the positive pole to G and negative pole to G0. CAUTION: use separate cables for serial connections and power supply. COMMUNICATION LINES RS485 communication lines The maximum length must not be over 1000m, via AWG24 shielded cable, with screen connection to earth and not to GND. The 120Ω terminal resistors, 1/4W into the first and the last devices of the network, must be connected even if the lenght exceeds 100 meters. The resistors, included in the product, are to be connected between the serial + and - terminals: • observe the polarity (+.-,GND); • do not make branches in the line or star connections; • avoid laying the line near power cables. To improve immunity of the controller to electromagnetic disturbance, the serial connection cable must be twisted pair shielded, twisted two- or three-wire depending on the insulation of the serial connection. The following rule applies: • if the serial port is insulated (functionally) from the power supply, a third wire is required in the serial cable to act as a common reference for the controllers; • if the serial port is not optically-isolated and the common reference is already present, the third wire is not needed. RJ45 Ethernet Linee Use shielded cables 100 m Cat.5e SFTP. To connect earth the screen ethernet cable (functional connection), use a female Faston 6,3mm, as indicated inthe figure. The product is class II classified, but there is a faston for the earth connection (functional) shiel cable. The connection could be directed to earth (protection) or, earth (functional) separated by dangerous voltages from to other external power supplies.
Carel CloudGate Assembly procedures Thumbnail

Carel CloudGate Assembly procedures [PDF] (2 pages)

  • Identifier: id-1767474
  • Brand: Carel
  • Device: Carel CloudGate Gateway
  • Type: Assembly procedures, PDF
  • Key Aspects: System Connectivity and Wiring Basics, Hardware Verification Checklists, Technical Data and Parameters
  • UPD Date: 28.03.2026
  • Source File: 1772801.pdf
  • Pages: 2
  • Description: Quick reference guide for the Carel CloudGate.
Pages Preview:
  • Carel CloudGate Assembly procedures preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
CloudGate: Istruzioni di montaggio / Assembly procedure "CloudGate" +0500150IE - rel. 1.0 - 11.09.2019 DESCRIZIONE CONNETTORI / CONNECTOR’S DESCRIPTION G G0 2 24V~/24V 20VA/9W LAN FIELD 6 7 9 11 13 8 1 10 12 4 2 5 3 Legenda / key: Descrizione Description 1 Connettore per l’alimentazione [G(+), G0(-)] 24Vac/Vdc Power supply connector [G(+), G0(-)] 24Vac/Vdc 2 LED power-on (verde) / LED power-on (green) 3 Led segnalazione Ethernet / Ethernet signal Led 4 Abilitazione IP temporaneo / WPS / check connessione al cloud (solo per mod. 2G/4G) Enable temporary IP / WPS / connection check to cloud (only for 2G/4G mod.) 5 Porta USB standard HOST, connettore tipo A, per upgrading FW e log files downloading USB standard HOST Port, type A connector, upgrading FW and log files downloading 6 Seriale RS485 Optoisolata / RS485 serial opto-isolated; 7 Seriale RS485 Non Optoisolata / RS485 serial not opto-isolated; 8 Ethernet FIELD / FIELD Ethernet; 9 Ethernet LAN / LAN Ethernet; 10 Faston collegamento a terra calza ethernet / Faston for shield ethernet port earth connection 11 Connettore per antenna 2G/4G / 2G/4G Antenna connector (*) 12 Connettore per antenna Wi-Fi / Wi-Fi Antenna connector (*) 13 Sinottico LED / LED synoptic (*) Le due opzioni Wi-Fi e 2G/4G sono disponibili l'una in alternativa all'altra / The two options Wi-Fi and 2G / 4G are available as an alternative to the other SIGNIFICATO DEI LEDS / LEDS MEANINGS Versione Ethernet / Ethernet version IP A C D B Descrizione Description A Connessione Cloud / Cloud connection B Ottenimento indirizzo IP / IP address assigned C Connessione Ethernet / Ethernet connection D Motore software: lampeggiante: in caricamento; fisso: in funzione Software engine: flashing: loading; steady: functioning Versione CloudGate Mobile (wi-fi o 2G/4G) / CloudGate Mobile (wi-fi or 2G/4G) vers. A C D B E Descrizione Description A Connessione Cloud / Cloud connection B Ottenimento indirizzo IP / IP address assigned C Connessione Radio / Radio connection D Motore software: lampeggiante: in caricamento; fisso: in funzione Software engine: flashing: loading; steady: functioning E Intensità segnale Radio: Led verdi: 2G/4G; Led gialli: Wi-Fi Radio signal strength: green Led: 2G/4G; yellow Led: Wi-Fi DIMENSIONI / DIMENSIONS 70 60 110 45 IP Montaggio DIN: agganciabile su guida DIN secondo DIN 43880 CEI EN 50022 DIN mounting: fitted on DIN rail in accordance with DIN 43880 and IEC EN 50022; ATTENZIONE Quest’apparecchiatura deve essere installata esclusivamente da personale di servizio con adeguato addestramento tecnico ed esperienza per essere consapevole dei pericoli a cui può essere esposto in caso di configurazione erronea (installatori abilitati). NOTE GENERALI Prima di passare a qualsiasi operazione si raccomanda di controllare che nella scatola di CloudGate siano presenti: 1. il dispositivo stesso; 2. nelle versioni wireless una antenna (tipo Wi-Fi o 2G/4G); 3. documentazione tecnica; 4. kit morsetti estraibili e due resistori da 120Ω per terminazione di linea seriale. Evitare il montaggio del prodotto in ambienti che presentino le seguenti caratteristiche: • umidità relativa maggiore di quanto indicato nelle specifiche tecniche; • forti vibrazioni o urti; • esposizione ad atmosfere aggressive ed inquinanti (es.: gas solforici e ammoniacali, nebbie saline, fumi) con conseguente corrosione e/o ossidazione; • elevate interferenze magnetiche e/o radiofrequenze (evitare quindi l’installazione delle macchine vicino ad antenne trasmittenti); • esposizione all’irraggiamento solare diretto e agli agenti atmosferici in genere; • ampie e rapide fluttuazioni della temperatura ambiente; • ambienti ove sono presenti esplosivi o miscele di gas infiammabili. Avvertenze per l’installazione per i modelli con radio • Prima di installare il prodotto verificare che la zona sia coperta adeguatamente dal segnale 2G/4G - Wi-Fi, se il modello da utilizzare prevede tale connettività radio; • Posizionare l’antenna al di fuori di carpenterie metalliche. CARATTERISTICHE TECNICHE Alimentazione tra G e G0: 24 Vac +10%/-15% 50/60 Hz, 24 Vdc +5% /-5% Potenza ingresso Max 9W Cond. di Funzionamento -40T60 °C, 90% U.R. non-condensante Cond. di Stoccaggio -40T70 °C, 90% U.R. non-condensante 2 uscite digitali Open-collector, per ogni uscita max carico 20mA 1 ingresso contatto pulito: max 20Vdc, max 5mA Porte seriali 1 RS485 Master optoisolata - 1 RS485 Master non optoisolata Batteria interna Batteria Lithium bottone, BR2032, 3 Vdc, NON ricaricabile Requisiti di certificazione: RED: - WIFI - 2G/4G EN 301 489-1 EN 301 489-17 Ver. 3.1.1 - EN 300 328 Ver. 2.1.1 EN 301 489-52 Ver. 1.1.0 - EN 301 511 Ver. 12.5.1 - EN 301 908-1 Ver. 11.1.1 FCC: - WIFI+2G/4G: FCC Part 15 Subpart B, ICES003 FCC Part 15.31 (k) - ANSI C95.1. MPE - RSS-102. MPE Safety: 60950; 62368 Dimensioni modulo 4 DIN = 70x110x60 mm Grado di inquinamento 2 secondo EN60950-1 / EN62368-1 Grado di protezione IP10 Materiale del contenitore tecnopolimero Non aprire il dispositivo quando alimentato. Alimentazione • L’alimentazione del prodotto si deve effettuare unicamente tra G e G0. • Lunghezza massima=5 m. • Se alimentato in alternata utilizzare un trasformatore dedicato di sicurezza di classe 2 da 24Vac, 20...30VA, protetto contro il cortocircuito e il sovraccarico, senza collegare il secondario a terra. • Se alimentato in continua usare l’alimentatore PGTA00TRX0, 100/230Vac-24Vdc (10W ±2% 1 modulo DIN, Temperatura minima = -25°C). Collegare il polo positivo a G e il negativo a G0. ATTENZIONE: utilizzare cavi separati per connessioni seriali e alimentazione. LINEE DI COMUNICAZIONE Linee di comunicazione RS485 La lunghezza massima non deve superare i 1000m, tramite cavo schermato AWG24, con connessione dello schermo a terra e non a GND. Le resistenze di terminazione 120 Ω, 1/4W sul primo e sull’ultimo dispositivo della rete vanno messe se la lunghezza della stessa supera i 100 m. Le resistenze, incluse nel prodotto, sono da collegare tra i morsetti seriale + e -: • rispettare la polarità (-,+,GND); • non realizzare biforcazioni della linea o collegamenti a stella; • evitare di posizionare la linea in prossimità delle linee di potenza. Per migliorare l’immunità del controllo ai disturbi elettromagnetici, il cavo di collegamento delle seriali deve essere a coppie ritorte (twisted pair) schermato, bipolare o tripolare in dipendenza dall’isolamento della seriale. Vale la seguente regola: • se la porta seriale è optoisolata (funzionalmente) rispetto all’alimentazione, occorre un terzo filo di collegamento nel cavo seriale per dare un riferimento comune ai controlli; • se la porta seriale non è optoisolata e il riferimento comune è già presente, il terzo filo non è usato. Linee Ethernet RJ45 Utilizzare cavo schermato 100 m Cat.5e SFTP. Per collegare lo schermo del cavo ethernet a terra funzionale, utilizzare un Faston femmina da 6,3mm come indicato in figura. Il prodotto è di classe II, ma è presente il faston per la messa a terra funzionale della schermatura del cavo Ethernet. Il collegamento potrebbe essere verso una terra di protezione o, eventualmente una terra funzionale separata da tensioni pericolose fornite da altre alimentazioni esterne. WARNING This appliance must only be installed by service personnel with suitable technical training and experience and who are aware of the dangers they may be exposed to in the event of incorrect configuration (qualified installers). GENERAL NOTE Before performing any operations, check that the CloudGate contains: 1. the device itself; 2. for wireless version: an antenna ( Wi-Fi or 2G/4G type); 3. technical documents; 4. terminals kit and two resistors 120Ω for the end of the serial line. Do not install products in environments with the following characteristics: • relative humidity greater than the value specified in the technical specifications; • strong vibrations or knocks; • exposure to aggressive and polluting atmospheres (e.g.: sulphur and ammonia fumes, saline mist, smoke) so as to avoid corrosion and/or oxidation; • strong magnetic and/or radio frequency interference (therefore avoid installing the units near transmitting antennae); • exposure to direct sunlight and to the elements in general; • large and rapid fluctuations in the room temperature; • environments where explosives or mixes of flammable gases are present. Installation warnings for Radio models • Before installing the product make sure the area is sufficiently covered by a 2G/4G - Wi-Fi signal, if the model to be used includes radio connectivity; • locate the antenna outside metal hardware. TECHNICAL SPECIFICATIONS Power supply from G to G0: 24 Vac +10%/-15% 50/60 Hz, 24 Vdc +5% /-5% Input power 9W Max Operating conditions -40T60 °C, 90% U.R. non-condensing Storage conditions -40T70 °C, 90% U.R. non-condensing 2 digital outputs Open-collector, on each output 20mA max. load 1 input free contact: 20Vdc max, 5mA max Serial Ports 1 RS485 Master opto-isolated- 1 RS485 Master non opto-isolated Battery (internal) Lithium “button” type, BR2032, 3 Vdc, NON rechargeable Certification requirements RED: - WIFI - 2G/4G EN 301 489-1 EN 301 489-17 Ver. 3.1.1 - EN 300 328 Ver. 2.1.1 EN 301 489-52 Ver. 1.1.0 - EN 301 511 Ver. 12.5.1 - EN 301 908-1 Ver. 11.1.1 FCC: - WIFI+2G/4G FCC Part 15 Subpart B, ICES003 FCC Part 15.31 (k) - ANSI C95.1. MPE - RSS-102. MPE Safety: 60950; 62368 Dimensions 4 DIN module = 70x110x60 mm Pollution degree 2 according to EN60950-1 / EN62368-1 Index of protection IP10 Case material tecnopolymer Do not open the device when powered. Power supply • Power supply to the product must only be connected between G and G0 • Maximum length =5 m. • If AC powered, use a dedicated safety transformer rated in Class 2 24Vac, 20...30VA, protected against short-circuits and overload, without secondary must be earthed connected. • If direct current powered use PGTA00TRX0 power supply, 100/230Vac- 24Vdc (10W ±2% 1 DIN-module, Minimum Temperature = -25°C). Connect the positive pole to G and negative pole to G0. CAUTION: use separate cables for serial connections and power supply. COMMUNICATION LINES RS485 communication lines The maximum length must not be over 1000m, via AWG24 shielded cable, with screen connection to earth and not to GND. The 120Ω terminal resistors, 1/4W into the first and the last devices of the network, must be connected even if the lenght exceeds 100 meters. The resistors, included in the product, are to be connected between the serial + and - terminals: • observe the polarity (+.-,GND); • do not make branches in the line or star connections; • avoid laying the line near power cables. To improve immunity of the controller to electromagnetic disturbance, the serial connection cable must be twisted pair shielded, twisted two- or three-wire depending on the insulation of the serial connection. The following rule applies: • if the serial port is insulated (functionally) from the power supply, a third wire is required in the serial cable to act as a common reference for the controllers; • if the serial port is not optically-isolated and the common reference is already present, the third wire is not needed. RJ45 Ethernet Linee Use shielded cables 100 m Cat.5e SFTP. To connect earth the screen ethernet cable (functional connection), use a female Faston 6,3mm, as indicated inthe figure. The product is class II classified, but there is a faston for the earth connection (functional) shiel cable. The connection could be directed to earth (protection) or, earth (functional) separated by dangerous voltages from to other external power supplies.

Similar Manuals in the Gateway, Network Hardware Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
RAKwireless RAK7258

RAKwireless RAK7258 Guide (Operation & user’s manual), @5GUG14

12 398 96 14-07-2026 view all manuals
Chamberlain EL Series

Chamberlain IP Access Controllers Programming manual (File: PDF, 15-04-2026)

144 430 104 15-04-2026 view all manuals
Chorus Hyperfibre XGS-250WX-A

#6DZL5Z: Hyperfibre XGS-250WX-A Gateway Operation & user’s manual

73 839 143 02-07-2026 view all manuals
Avaya S8500 Series

#C65P25: S8500 Series Server Manual 

146 89 19 23-05-2026 view all manuals
ZyXEL Communications P-792H

P-792H (Gateway ePDF User Guide, #R9581O)

472 9.05 Mb 1287 194 10-05-2026 view all manuals
D-Link VoIP Wireless Router DVG-G5402SP

#S6GK6F: VoIP Wireless Router DVG-G5402SP Wireless Router Operation & user’s manual

106 1.5 Mb 1096 274 15-06-2026 view all manuals