Carrier SBP SMALL BYPASS HUMIDIFIER Manuals
1 pdf manual(s) Carrier SBP SMALL BYPASS HUMIDIFIER for free download (Document Types: Manual )
Carrier SBP SMALL BYPASS HUMIDIFIER Manual [PDF] (2 pages)
- Identifier: id-969316
- Brand: Carrier
- Device: Carrier SBP SMALL BYPASS HUMIDIFIER Humidifier
- Type: Manual , PDF
- Key Aspects: Operational Mode Explanations, Unpacking and Inspection Guidelines, Component Longevity Optimization
- UPD Date: 15.06.2026
- Source File: 1189189.pdf
- Pages: 2
- Description: Instruction and reference manual for the Carrier SBP SMALL BYPASS HUMIDIFIER.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
MANUAL HUMIDISTAT 24 VAC SOLENOID VALVE LEADS HUMIDIFIER 24 VAC TERMINALS ON FURNACE NOTE: CONNECT SOLENOID VALVE TO HOT WATER IF HUMIDIFIER WILL BE OPERATED INDEPENDENT OF HEATING CALLS. HUMIDIFIER TRANSFORMER (FIELD SUPPLIED) 120 VAC 24 VAC 24 VAC SOLENOID VALVE LEADS MANUAL HUMIDISTAT 120 VAC “EAC” TERMINALS ON FURNACE (R) 24 VAC HOT TERMINAL NOTE: FOR APPLICATIONS WITH THERMIDISTAT™REFER TO THERMIDISTAT™INSTALLATION INSTRUCTIONS. WARNING: DO NOT CONNECT FURNACE HUM TERMINAL DIRECTLY TO THERMIDISTAT™HUM TERMINAL INDOOR EQUIPMENT (HUM) TERMINAL HUMIDIFIER THERMIDISTAT™ CONTROL 24 VAC SOLENOID VALVE LEADS EQUIPMENT CONTROLLER HUMIDIFIER INDOOR UNIT 24 VAC SOLENOID VALVE LEADS HUMIDIFIER INDOOR UNIT 24 VAC SOLENOID VALVE LEADS READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock. This product must be installed in compliance with all local, state and federal codes. ATTENTION INSTALLER: SBP SMALL BYPASS HUMIDIFIER The humidifier can be installed on either the supply or return plenum of a forced air handling system and is easily reversible for installation with right hand or left hand bypass duct connections. The humidifier dimensions and serviceability must be considered when selecting the best location for the humidifier. RETURN SUPPLY S RETURN R SUPPLY S Horizontal Upflow 90-1115 90-1116 90-1117 90-1118 90-1119 90-1079 WARNING 1. ELECTRICAL SHOCK HAZARD. Disconnect electrical power to the furnace and install lock-out tag before starting installation. Failure to do so could result in serious injury from electrical shock. 2. SHARP EDGES HAZARD. Sharp edges may cause serious injury from cuts. Use care when making plenum openings and handling ductwork. 3. RISK OF SCALDING. Water temperature over 125°F can cause severe burns and scald instantly. Shut off the hot water supply before disconnecting or tapping into any hot water supply line. SPECIFICATIONS HUMIDIFIER DIMENSIONS Width (including solenoid valve): 15 5⁄8” Height (including drain spud): 13” Depth: 101⁄4” BYPASS DUCT OPENING 6” diameter PLENUM OPENING 9 1⁄2”W x 9 1⁄2”H WATER FEED RATE 3 gph ELECTRICAL DATA 24 VAC-60 Hz, 0.5 AMP CAUTION 1. Do not install humidifier where freezing temperatures could occur. The water line could freeze and crack causing water damage to the home. 2. Do not install humidifier or bypass connection on the furnace cabinet. 3. Do not install humidifier or bypass connection on a plenum face where the blanked off ends of the cooling coil will restrict air movement through the humidifier. 4. Do not set humidity level above recommended or to recommended level if condensation exists on inside windows of any unheated space, as condensation damage may result. Excess humidity can cause moisture accumulation which can allow the possibility for mold growth in the home. 5. Do not connect humidifier transformer to blower motor wiring. Premature component failure may result. 6. When installing Humidifier Control on downflow furnace, ensure blower continues to run after a heat call is satisfied to eliminate high temperatures from damaging the Control. 7. Do not install humidifier where water pressure exceeds 125 psi, since damage to the humidifier may result. Follow codes in effect concerning pressure reduction. 8. Do not install humidifier on systems with greater than 0.4 in. wg pressure differential between supply and return plenums. RISK OF PROPERTY AND EQUIPMENT DAMAGE. INSTALLATION OPTIONS WIRING DIAGRAMS HumidiTrac™ Automatic Humidifier Control For detailed Automatic Humidifier Control installation and wiring instructions, see Form IM-AHC-02 included with Control. DIAGRAM A FOR OPERATION DURING “HEAT CALL” ONLY DIAGRAM B FOR OPERATION WHEN BLOWER IS ENERGIZED DIAGRAM D ZONING HOOK-UP WITH EQUIPMENT CONTROLLER DIAGRAM E NEW COMMUNICATING CONTROL HOOK-UP WITH ALL INDOOR EQUIPMENT DIAGRAM C FOR HUMIDIFIER OPERATION WITH THERMIDISTAT™CONTROL ©2010 CAC/BDP 7310 West Morris St., Indianapolis, IN 46231 TEMPLATE MUST BE LEVEL
Similar Manuals in the Humidifier Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Elechomes SH8820W |
Manual: Elechomes SH8820W (C7V69M, Upd.27-06-2026) |
24 | 640 | 141 | 27-06-2026 | view all manuals | |
GeneralAire 800 |
PDF Manual (@UI2315), GeneralAire 800 Humidifier (24-04-2026) |
8 | 900 | 144 | 24-04-2026 | view all manuals | |
easywell EW-05HS |
#8J1658: EW-05HS Humidifier Operation manual |
10 | 1458 | 219 | 22-08-2026 | view all manuals | |
Hisense Breezy |
Manual: Hisense Breezy (249JXB, Upd.01-07-2026) |
8 | 2.39 Mb | 697 | 147 | 01-07-2026 | view all manuals |
Nortec GS 100 |
Nortec GS 100 User Guide (Installation, user & maintenance manual), @49MF13 |
78 | 1075 | 226 | 08-08-2026 | view all manuals | |
Philips HU4803 |
HU4803 (Humidifier ePDF Manual, #127NEY) |
66 | 692 | 118 | 01-07-2026 | view all manuals |