SERVICE MANUAL
ELECTRONIC CASH REGISTER
(without price)
Printer Model : M-42V
120CR (EX-268B)
160CR (EX-268B)
SEP. 2000
CONTENTS
120CR
160CR
Page
1. SPECIFICATIONS........................................................................................ 1
2. INITIALIZE (MAC) OPERATION.................................................................. 2
3. BLOCK DIAGRAM....................................................................................... 3
3-1. PCB CONNECTION ..................................................................................................... 3
3-1. BLOCK DIAGRAM....................................................................................................... 4
4. DISASSEMBLY ............................................................................................ 5
5. CIRCUIT EXPLANATION ............................................................................ 8
5-1. Power supply circuit .................................................................................................. 8
5-2. Reset circuit ................................................................................................................ 9
5-3. Data communication between CPU and EEPROM ................................................ 10
5-4. Printer drive circuit................................................................................................... 12
5-5. Pin description (CPU uPD78043FGF) ..................................................................... 12
6. DIAGNOSTIC OPERATIONS .................................................................... 14
6-1. To start the diagnostic operation............................................................................ 14
6-2. Check items .............................................................................................................. 14
6-3. Operations................................................................................................................. 15
7. ERROR CODE LIST................................................................................... 19
7-1. Operation error code ................................................................................................ 19
8. IC DATA ..................................................................................................... 20
9. PCB LAYOUT ............................................................................................ 21
10. CIRCUIT DIAGRAM ................................................................................... 22
11. PARTS LIST............................................................................................... 29
— 1 —
• CPU
Name
µPD78043FGF076-3B9
Number of control bit
8bit
RAM (Built-in)
624 Kbits
• ROM
Name
BR93LC46A
Capacity
1024 bits
• Printer
Name
M-42V-009-040
Print method
Print wheel selecting type serial printer
MCBF
700,000 lines
Life
• Roll paper
Type
Fine-quality paper
Size
Width 57.5 ± 0.5 mm
Roll diameter
80 mm or less
1. SPECIFICATIONS
1-1.
Electrical specifications
120 V
220 V
230 V
240 V
• Power consumption
In operation
Max.
0.11 A
0.05 A
0.06 A
0.06 A
Min.
0.07 A
0.04 A
0.05 A
0.05 A
Power OFF
0.06 A
0.03 A
0.04 A
0.04 A
• Memory protection
Back-up battery
Mangan Battery (UM-3 × 3 pcs)
Back-up period
1 year (25 °C)
Battery life
Replace the battery every 1 years.
• Clock & Calendar
Accuracy
Within ± 30 sec. per month
Auto calendar
Effective until 2099 A.D.
1-2.
Environmental specifications
• Operating temperature
0 °C ~ 40 °C
• Operating humidity
10 % ~ 90 %
• Storage temperature
-25 °C ~ 65 °C
• Storage humidity
10 % ~ 95 %
• Vibration strength
1.5 G (The machine must be in the carton box)
1-3.
Main components
— 2 —
DEVICE NAME
MODEL
NOTE
• Wet cover
WT-80
• INK ROLL
IR-40
1-5.
Option List
1-4.
Drawer List
DRAWER NAME
Specification
NOTE
• DL-1838
(S type)
Europe, UK, Germany, Other countries
• DL-2768
(M type)
Europe, UK, Other countries
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type
recommended by the manufacturer.
Dispose of used batteries according
to the manufacture’s instructions.
VORSICHT !
Explosionsgefahr bei unsachgemäßem Austausch der Batterie.
Ersatz nur durch denselben oder einen vom
Hersteller empfohlenen gleichwertigen Typ.
Entsorgung gebrauchter Batterien nach
Angaben des Herstellers.
ADVARSEL !
Lithiumbatteri - Eksplosionsfare ved fejlagtig hándtering.
Udskiftning má kun ske med batteri
af samme fabrikat og type.
Levér det brugte batteri tilbage til leverandØren.
2. INITIALIZE (MAC) OPERATION
1. Set the Mode Switch to OFF.
2. Plug the power cord of the ECR off an AC outlet.
3. Remove the memory protection batteries.
4. Leave the ECR a few minutes and plug the power cord into an AC outlet.
5. Set the memory protection batteries.
6. Turn the Mode Switch to REG position.