CMC Patient Tie-In System Manuals

2 pdf manual(s) CMC Patient Tie-In System for free download (Document Types: Important information)

CMC Patient Tie-In System Important information Thumbnail

CMC Patient Tie-In System Important information [PDF] (2 pages)

  • Identifier: id-1624745
  • Brand: CMC
  • Device: CMC Patient Tie-In System Medical Equipment
  • Type: Important information, PDF
  • Key Aspects: Hardware Setup Instructions, Risk Mitigation and Accident Prevention, System Connectivity and Wiring Basics
  • UPD Date: 08.06.2026
  • Source File: 1605578.pdf
  • Pages: 2
  • Description: Operating manual for the CMC Patient Tie-In System.
Pages Preview:
  • CMC Patient Tie-In System Important information preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
CMC Rescue, Inc. 6740 Cortona Drive, Goleta CA 93117 USA 805-562-9120 / 800-235-5741 cmcpro.com ISO 9001 Certified ©2018 CMC Control No. 724152.01.012418 WARNING • SERIOUS INJURY OR DEATH MAY RESULT FROM THE IMPROPER USE OF THIS EQUIPMENT. • THIS EQUIPMENT HAS BEEN DESIGNED AND MANUFAC- TURED FOR USE BY EXPERIENCED PROFESSIONALS ONLY. • DO NOT ATTEMPT TO USE THIS EQUIPMENT WITHOUT PRIOR TRAINING. • THOROUGHLY READ AND UNDERSTAND ALL LABELS AND INSTRUCTIONS BEFORE USE. • USE, INSPECT AND REPAIR ONLY IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS. IMPORTANT INFORMATION - PLEASE READ AND SAVE Patient Tie-In System, Two-Piece Litter Made in USA of US and foreign components USER INFORMATION User Information shall be provided to the user of the product. CMC recommends separating the User Information from the equipment and retaining the information in a permanent record. CMC also recommends making a copy of the information to keep with the equipment and that the information should be referred to before and after each use. INSPECTION Inspect the equipment according to your department's policy for inspecting life safety equipment. Inspect the equipment prior to entry into service, after each use, and at least once every 12 months. The equipment should be thoroughly inspected by an inspector that meets your department's training standard for inspection of life safety equipment. Keep a record of the date, person performing the inspection and results, as well as the date of first use, name of users and any other pertinent information necessary to keep accurate track of the equipment’s usage history in the equipment log or on a tag that attaches to the equipment. Each user should be trained in equipment inspection and should inspect the equipment before each use. When inspecting the equipment, check the webbing and rope for cuts, worn or frayed areas, broken fibers, soft or hard spots, discoloration, or melted fibers. Check the stitching for pulled threads, abrasion, or breaks. Check the hardware for damage, sharp edges, and improper operation. If any of the above is noted, or if the equipment has been subjected to shock loads, fall loads, or abuse other than normal use, remove the equipment from service and destroy it. If there is any doubt about the serviceability of the equipment, remove the equipment from service and destroy it. The service life of equipment depends greatly on the type of use and the environment of use. Because these factors vary greatly, a precise service life of the equipment cannot be provided. CARRYING, MAINTENANCE & STORAGE During use, carrying and storage keep the equipment away from acids, alkalis, exhaust emissions, rust and strong chemicals. Do not expose the equipment to flame or high temperatures. Carry the equipment where it will be protected as the equipment could melt or burn and fail if exposed to flame or high tempera- tures. If the equipment becomes soiled, it can be washed in cold water with a mild detergent that is safe for use with nylon and polyester. Dry out of direct sunlight. Do not dry in an automatic dryer. Store in a cool, dry location. Do not store where the equipment may be exposed to moist air, particularly where dissimilar metals are stored together. REPAIR All repair work shall be performed by the manufacturer. All other work or modifications void the warranty and releases CMC from all liability and responsibility as the manufacturer. SAMPLE LOG The sample log suggests records that should be maintained by the purchaser of the life safety equipment. Equipment Inspection and Maintenance Log Item __________ # __________ Date in Service ____________ Brand/Model _______________ Strength ___________________ Date How Used or Maintained Comments Name
CMC Patient Tie-In System Important information Thumbnail

CMC Patient Tie-In System Important information [PDF] (2 pages)

  • Identifier: id-1734674
  • Brand: CMC
  • Device: CMC Patient Tie-In System Medical Equipment
  • Type: Important information, PDF
  • Key Aspects: Documentation and Revision History, Hardware Verification Checklists, Storage and Care Recommendations
  • UPD Date: 07.07.2026
  • Source File: 1805608.pdf
  • Pages: 2
  • Description: Installation and maintenance guide for the CMC Patient Tie-In System.
Pages Preview:
  • CMC Patient Tie-In System Important information preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
IMPORTANT INFORMATION - PLEASE READ AND SAVE Patient Tie-In System, One-Piece Litter Made in USA of US and foreign components USER INFORMATION User Information shall be provided to the user of the product. CMC recommends separating the User Information from the equipment and retaining the information in a permanent record. CMC also recommends making a copy of the information to keep with the equipment and that the information should be referred to before and after each use. INSPECTION Inspect the equipment according to your department's policy for inspecting life safety equipment. Inspect the equipment prior to entry into service, after each use, and at least once every 12 months. The equipment should be thoroughly inspected by an inspector that meets your department's training standard for inspection of life safety equipment. Keep a record of the date, person performing the inspection and results, as well as the date of first use, name of users and any other pertinent information necessary to keep accurate track of the equipment’s usage history in the equipment log or on a tag that attaches to the equipment. Each user should be trained in equipment inspection and should inspect the equipment before each use. When inspecting the equipment, check the webbing and rope for cuts, worn or frayed areas, broken fibers, soft or hard spots, discoloration, or melted fibers. Check the stitching for pulled threads, abrasion, or breaks. Check the hardware for damage, sharp edges, and improper operation. If any of the above is noted, or if the equipment has been subjected to shock loads, fall loads, or abuse other than normal use, remove the equipment from service and destroy it. If there is any doubt about the serviceability of the equipment, remove the equipment from service and destroy it. The service life of equipment depends greatly on the type of use and the environment of use. Because these factors vary greatly, a precise service life of the equipment cannot be provided. CARRYING, MAINTENANCE & STORAGE During use, carrying and storage keep the equipment away from acids, alkalis, exhaust emissions, rust and strong chemicals. Do not expose the equipment to flame or high temperatures. Carry the equipment where it will be protected as the equipment could melt or burn and fail if exposed to flame or high tempera- tures. If the equipment becomes soiled, it can be washed in cold water with a mild detergent that is safe for use with nylon and polyester. Dry out of direct sunlight. Do not dry in an automatic dryer. Store in a cool, dry location. Do not store where the equipment may be exposed to moist air, particularly where dissimilar metals are stored together. REPAIR All repair work shall be performed by the manufacturer. All other work or modifications void the warranty and releases CMC from all liability and responsibility as the manufacturer. SAMPLE LOG The sample log suggests records that should be maintained by the purchaser of the life safety equipment. Equipment Inspection and Maintenance Log Item __________ # __________ Date in Service ____________ Brand/Model _______________ Strength ___________________ Date How Used or Maintained Comments Name CMC Rescue, Inc. 6740 Cortona Drive, Goleta CA 93117 USA 805-562-9120 / 800-235-5741 cmcpro.com ISO 9001 Certified ©2018 CMC Control No. 724151.01.012418 WARNING • SERIOUS INJURY OR DEATH MAY RESULT FROM THE IMPROPER USE OF THIS EQUIPMENT. • THIS EQUIPMENT HAS BEEN DESIGNED AND MANUFAC- TURED FOR USE BY EXPERIENCED PROFESSIONALS ONLY. • DO NOT ATTEMPT TO USE THIS EQUIPMENT WITHOUT PRIOR TRAINING. • THOROUGHLY READ AND UNDERSTAND ALL LABELS AND INSTRUCTIONS BEFORE USE. • USE, INSPECT AND REPAIR ONLY IN ACCORDANCE WITH MANUFACTURER’S INSTRUCTIONS.

Similar Manuals in the Medical Equipment Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Kyoto Kagaku MW2A

PDF Manual (@4DX4I6), Kyoto Kagaku MW2A Medical Equipment (30-03-2026)

50 443 111 30-03-2026 view all manuals
DMP Electronics XTLtouch

DMP Electronics Touch Panel Installation manual (File: PDF, 02-08-2026)

28 284 63 02-08-2026 view all manuals
Gima 27399

27399 (Baby & Toddler Furniture ePDF Manual, #7V4L9L)

8 943 151 26-05-2026 view all manuals
CAIRE Liberator 30

Oxygen Equipment #DLNF71

16 438 92 09-08-2026 view all manuals
Stryker T/Pump Series

T/Pump Series (Medical Equipment ePDF Guide, #NO7747)

54 1245 262 27-07-2026 view all manuals
Philips M3001A

Manual: Philips M3001A (Y6E142, Upd.02-05-2026)

293 296 74 02-05-2026 view all manuals