COBHAM EXPLORER 540 Manuals

8 pdf manual(s) COBHAM EXPLORER 540 for free download (Document Types: Installation manual, Setup manual, User & integrator's manual)

COBHAM EXPLORER 540 Installation manual [PDF] (2 pages)

  • Identifier: id-823736
  • Brand: COBHAM
  • Device: EXPLORER 540 Conference System
  • Type: PDF
  • Key Aspects: Troubleshooting Information, User Training Recommendations, Safety Recommendations and Warnings
  • UPD Date: 13.07.2026
  • Source File: 816026.pdf
  • Pages: 2
  • Description: Setup and usage guide for the COBHAM EXPLORER 540.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
What’s in the box? Step 2: Connect cables Step 3: Install the EXPLORER 540 EXPLORER 540 Installation guide Step 1: Insert SIM card If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Cleaning: Clean the exterior of the EXPLORER 540 with a damp cloth. X2: Ethernet, RJ-45 X1: Ethernet, Spring-loaded terminals X4: DC input, Screw terminals X5: I/O, Spring-loaded terminals X6: USB Micro B (in the side wall - not visible here) X7: Chassis GND, Screw terminal LED = LED = EXPLORER 540 terminal with pole mount kit Disclaimer: Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by Thrane & Thrane A/S. The information in this manual is provided for information purposes only, is subject to change without notice and may contain errors or inaccuracies. The manuals are periodically revised and updated. Anyone relying on this information should acquire the most current version e.g. from cobham.com/satcom or from the distributor. Thrane & Thrane A/S is not responsible for the content or accuracy of any translations or reproductions, in whole or in part, of this manual from any other source. Thrane & Thrane A/S trading as Cobham SATCOM. Copyright © 2016 Thrane & Thrane A/S. All rights reserved. Manufacturer address: Thrane & Thrane A/S, Lundtoftegaardsvej 93 D, DK-2800, Kgs. Lyngby, Denmark You need a BGAN SIM card for either BGAN M2M or BGAN class 2 services. To insert the SIM card, do as follows: NOTE: Make sure the EXPLORER 540 is not powered when you insert or remove the SIM card! 1. Open the cover for the interface enclosure at the back of the EXPLORER 540. Use the included Torx bit to unscrew the screws. 2. Locate the SIM holder in the middle of the compartment. 3. Slide the lock to release the SIM holder. 4. Lift the end of the SIM holder and insert the SIM card as shown. 5. Lower the SIM card holder with the SIM card inserted and lock it. 6. When all cables are connected, put the cover back on and tighten the screws. NOTE: Make sure the PIN for the SIM card is either disabled or set up for automatic valida- tion. For details, see the EXPLORER 540 User and integrator’s manual. A pole mount kit is included in the package. To mount the EXPLORER 540 on a pole, do as follows: 1. Attach the base of the pole mount bracket to the EXPLORER 540 using the included Hex L key on the 4 screws. Caution! Max. length of the screws is 9 mm! Longer screws can damage the EXPLORER 540. 2. Unscrew two of the long screws from the pole mount kit to leave one side open for the pole. 3. Place the pole mount kit with the EXPLORER 540 around the pole as shown. 4. Remount the two remaining long screws. Do not tighten the screws completely until you have pointed the antenna. 5. Power up the system. Observe the LED between the cable glands (see LED description on the back). •� LED�flashing�rapidly�green:�Starting�up •� LED�flashing�yellow:�Pointing •� LED steady yellow: Warning! See Verification on the back. When�LED�flashes�yellow:�Turn�and�tilt�the� EXPLORER 540 and use the pointing sound to obtain the highest possible signal strength (continuous sound = best signal). When you have the highest possible signal strength, tighten all the screws on the pole mount kit to keep the EXPLORER 540 in the pointed position. The EXPLORER 540 will automatically exit the pointing process once it has detected a stable BGAN signal. When the pointing process has ended, the LED changes as follows: •� LED�flashing�green:� Verifying network connection •� LED steady green and then off: Ready - installation process has ended successfully. The LED is disabled (off) after a few minutes. Note: If the LED is steady yellow, it means the installation failed and there is a warning. If you can connect a computer locally to the EXPLORER 540, you can use the web interface to follow the progress on screen, see any warnings, and restart the installation if necessary. See Verification on the back. Note:�The�installation�will�fail�if�the�SIM�card�requires�a�user�defined�APN value and you have not yet entered this in the EXPLORER 540. Specify the APN value and restart the installation. For details, see the EXPLORER 540 User and integrator’s manual. To maintain the Ingress Protection rating of the EXPLORER 540 and to avoid cables acciden- tally being disconnected, all cable connections are made inside the interface enclosure at the back of the EXPLORER 540. Tools: •� Use the provided Torx bit to open the interface enclosure at the back of the terminal •� Use�a�flat�blade�screw�driver�(max.�2�mm�wide)�to�press�down�the�spring-loaded�terminals •� Use�a�flat�blade�screw�driver�(max.�3.5�mm�wide)�to�unscrew�and�fasten�the�screw�termi- nals 1. Lead the cable(s) through the cable gland(s) and gasket(s) (suitable for cable diameter 5-10 mm). For C1D2 installations, use cable glands that comply with NEC501.10b. Make sure�the�cable�glands�fit�tightly. 2. Connect the cables according to your configuration.�See�the�reverse�of�this� guide�for�pinout,�specifications�and� example�configuration�drawing. The RJ-45 connector of the LAN cable can pass through the cable gland. (see picture) 3. If you are not using PoE to power the EXPLORER 540, connect a power cable between the DC input terminals and a current-limited power supply or an external battery as described below. 4. When all cables are connected, mount the cover for the interface enclosure and tighten the screws with the included Torx bit. Important! If you only need to install one cable, mount the provided blind plug in the unu- sed hole to maintain the Ingress Protection (IP grade) of the terminal. To connect to the DC input: 1. Lead the cable through the cable gasket at the DC input. 2. If the DC cable is shielded, insert the end of the shield into the terminal marked 3-GND in the DC terminal block and tighten the screw to torque 4.5 lbf in. 3. Insert the negative wire into the terminal marked 2-DCIN- in the DC terminal block and tighten the screw to torque 4.5 lbf in. 4. Insert the positive wire into the terminal marked 1-DCIN+ in the DC terminal block and tighten the screw to torque 4.5 lbf in. 5. Tighten the cable gland. The following items are included in the delivery: •� EXPLORER 540 terminal •� Pole mount kit •� 2 ATEX-approved cable glands and 1 Blind plug •� Torx bit Size TX10 (tamper resi- stant, 1/4” Hex drive) for mounting/ unmounting the cover for the interface enclosure •� Installation guide (this guide) EXPLORER 540 User and integrator’s manual (part no. 98-148232) as well as other language versions of this installation guide are available for download at the Cobham SYNC Partner Portal. Go to www.cobham.com/satcom and select Cobham SYNC Partner Portal > Downloads.

COBHAM EXPLORER 540 Installation manual [PDF] (2 pages)

  • Identifier: id-2014642
  • Brand: COBHAM
  • Device: EXPLORER 540 Touch terminals
  • Type: PDF
  • Key Aspects: Detailed Installation Instructions, End-of-Life Handling and Disposal, Model Variations and Compatibility
  • UPD Date: 08.08.2026
  • Source File: 2273216.pdf
  • Pages: 2
  • Description: Complete instruction guide for the COBHAM EXPLORER 540.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
What’s in the box? Step 2: Connect cables Step 3: Install the EXPLORER 540 EXPLORER 540 Installation guide Step 1: Insert SIM card If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Cleaning: Clean the exterior of the EXPLORER 540 with a damp cloth. X2: Ethernet, RJ-45 X1: Ethernet, Spring-loaded terminals X4: DC input, Screw terminals X5: I/O, Spring-loaded terminals X6: USB Micro B (in the side wall - not visible here) X7: Chassis GND, Screw terminal LED = LED = EXPLORER 540 terminal with pole mount kit Disclaimer: Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by Thrane & Thrane A/S. The information in this manual is provided for information purposes only, is subject to change without notice and may contain errors or inaccuracies. The manuals are periodically revised and updated. Anyone relying on this information should acquire the most current version e.g. from cobham. com/satcom or from the distributor. Thrane & Thrane A/S is not responsible for the content or accuracy of any translations or reproductions, in whole or in part, of this manual from any other source. Thrane & Thrane A/S trading as Cobham SATCOM. Copyright © 2019 Thrane & Thrane A/S. All rights reserved. Manufacturer address: Thrane & Thrane A/S, Lundtoftegaardsvej 93 D, DK-2800, Kgs. Lyngby, Denmark You need a BGAN SIM card for either BGAN M2M or BGAN class 2 services. To insert the SIM card, do as follows: NOTE: Make sure the EXPLORER 540 is not powered when you insert or remove the SIM card! 1. Open the cover for the interface enclosure at the back of the EXPLORER 540. Use the included Torx bit to unscrew the screws. 2. Locate the SIM holder in the middle of the compartment. 3. Slide the lock to release the SIM holder. 4. Lift the end of the SIM holder and insert the SIM card as shown. 5. Lower the SIM card holder with the SIM card inserted and lock it. 6. When all cables are connected, put the cover back on and tighten the screws. NOTE: Make sure the PIN for the SIM card is either disabled or set up for automatic valida- tion. For details, see the EXPLORER 540 User and integrator’s manual. A pole mount kit is included in the package. To mount the EXPLORER 540 on a pole, do as follows: To maintain the Ingress Protection rating of the EXPLORER 540 and to avoid cables acciden- tally being disconnected, all cable connections are made inside the interface enclosure at the back of the EXPLORER 540. Tools: • Use the provided Torx bit to open the interface enclosure at the back of the terminal • Use a flat blade screw driver (max. 2 mm/ 0.08” wide) to press down the spring-loaded terminals • Use a flat blade screw driver (max. 3.5 mm/ 0.14” wide) to unscrew and fasten the screw terminals 1. Lead the cable(s) through the cable gland(s) and gasket(s) (suitable for cable diameter 5-10 mm/ 0.2”-0.4”). For C1D2 installations, use the supplied C1D2 approved cable glands. Make sure the cable glands fit tightly. 2. Connect the cables according to your configuration. See the reverse of this guide for pinout, specifications and example configuration drawing. The RJ-45 connector of the LAN cable can pass through the standard cable gland. (see picture) 3. If you are not using PoE to power the EXPLORER 540, connect a power cable between the DC input terminals and a current-limited power supply or an external battery as described below. 4. When all cables are connected, mount the cover for the interface enclosure and tighten the screws with the included Torx bit. Important! If you only need to install one cable, mount the provided blanking plug in the unused hole to maintain the Ingress Protection (IP grade) of the terminal. To connect to the DC input: 1. Lead the cable through the cable gasket at the DC input. 2. If the DC cable is shielded, insert the end of the shield into the screw terminal marked 3-GND and tighten the screw to torque 0.5 N m/ 4.5 lbf in. 3. Insert the negative wire into the termi- nal marked 2-DCIN - in the DC terminal block and tighten the screw to torque 0.5 N m /4.5 lbf in. 4. Insert the positive wire into the terminal marked 1-DCIN + in the DC terminal block and tighten the screw to torque 0.5 N m/ 4.5 lbf in. 5. Tighten the cable gland. The following items are included in the delivery: • EXPLORER 540 terminal • Pole mount kit • 2 standard cable glands • 2 C1D2 approved cable glands • 1 Blanking plug • Torx bit Size TX10 (tamper resi- stant, 1/4” Hex drive) for mounting/ unmounting the cover for the interface enclosure • Installation guide (this guide) EXPLORER 540 User and integrator’s manual (part no. 98-148232) as well as other language versions of this installation guide are available for download at the Cobham SYNC Partner Portal. Go to www.cobham.com/satcom and select Cobham SYNC Partner Portal > Downloads. Caution! Do not connect the positive or negative wire to 3-GND! Pole size 1” to 1.5” (33.7 to 48.3 mm) Note: If the LED is steady yellow, it means the installation failed and there is a warning. If you can connect a computer locally to the EXPLORER 540, you can use the web interface to follow the progress on screen, see any warnings, and restart the installation if necessary. See Verifying and troubleshooting the installation on the back. Note: The installation will fail if the SIM card requires a user defined APN value and you have not yet entered this in the EXPLORER 540. Specify the APN value and restart the installation. For details, see the EXPLORER 540 User and integrator’s manual. 1. Attach the base of the pole mount bracket to the EXPLORER 540 using the included Hex L key on the 4 screws. Cau- tion! Max. length of the screws is 9 mm/ 0.35”! Longer screws can damage the EXPLORER 540. 2. Unscrew two of the long screws from the pole mount kit to leave one side open for the pole. 3. Place the pole mount kit with the EXPLORER 540 around the pole as shown. 4. Remount the two remaining long screws. Do not tighten the screws completely until you have pointed the antenna. 5. Power up the system. Observe the LED between the cable glands (see LED description on the back). • LED flashing rapidly green: Starting up • LED flashing yellow: Pointing • LED steady yellow: Warning! See Verifying and troubleshooting the installation on the back. 6. When LED flashes yellow: Turn and tilt the EXPLORER 540 and use the pointing sound to obtain the highest possible signal strength (continuous sound = best signal). 7. When you have the highest possible signal strength, tighten all the screws on the pole mount kit to keep the EXPLORER 540 in the pointed positionThe EXPLORER 540 will automatically exit the pointing process once it has detected a stable BGAN signal. 8. When the pointing process has ended, the LED changes as follows: • LED flashing green: Verifying network connection • LED steady green and then off: Ready - installation process has ended successfully. The LED is disabled (off) after a few minutes.

COBHAM EXPLORER 540 Installation manual [PDF] (2 pages)

  • Identifier: id-2014643
  • Brand: COBHAM
  • Device: EXPLORER 540 Touch terminals
  • Type: PDF
  • Key Aspects: Initial Startup Checklist, Manufacturer Contact and Support Data, Performance Optimization Tips
  • UPD Date: 06.05.2026
  • Source File: 2273215.pdf
  • Pages: 2
  • Description: Technical operation manual for the COBHAM EXPLORER 540.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
What’s in the box? Step 2: Connect cables Step 3: Install the EXPLORER 540 EXPLORER 540 Installation guide Step 1: Insert SIM card If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Cleaning: Clean the exterior of the EXPLORER 540 with a damp cloth. X2: Ethernet, RJ-45 X1: Ethernet, Spring-loaded terminals X4: DC input, Screw terminals X5: I/O, Spring-loaded terminals X6: USB Micro B (in the side wall - not visible here) X7: Chassis GND, Screw terminal LED = LED = EXPLORER 540 terminal with pole mount kit Disclaimer: Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by Thrane & Thrane A/S. The information in this manual is provided for information purposes only, is subject to change without notice and may contain errors or inaccuracies. The manuals are periodically revised and updated. Anyone relying on this information should acquire the most current version e.g. from cobham. com/satcom or from the distributor. Thrane & Thrane A/S is not responsible for the content or accuracy of any translations or reproductions, in whole or in part, of this manual from any other source. Thrane & Thrane A/S trading as Cobham SATCOM. Copyright © 2019 Thrane & Thrane A/S. All rights reserved. Manufacturer address: Thrane & Thrane A/S, Lundtoftegaardsvej 93 D, DK-2800, Kgs. Lyngby, Denmark You need a BGAN SIM card for either BGAN M2M or BGAN class 2 services. To insert the SIM card, do as follows: NOTE: Make sure the EXPLORER 540 is not powered when you insert or remove the SIM card! 1. Open the cover for the interface enclosure at the back of the EXPLORER 540. Use the included Torx bit to unscrew the screws. 2. Locate the SIM holder in the middle of the compartment. 3. Slide the lock to release the SIM holder. 4. Lift the end of the SIM holder and insert the SIM card as shown. 5. Lower the SIM card holder with the SIM card inserted and lock it. 6. When all cables are connected, put the cover back on and tighten the screws. NOTE: Make sure the PIN for the SIM card is either disabled or set up for automatic valida- tion. For details, see the EXPLORER 540 User and integrator’s manual. A pole mount kit is included in the package. To mount the EXPLORER 540 on a pole, do as follows: To maintain the Ingress Protection rating of the EXPLORER 540 and to avoid cables acciden- tally being disconnected, all cable connections are made inside the interface enclosure at the back of the EXPLORER 540. Tools: • Use the provided Torx bit to open the interface enclosure at the back of the terminal • Use a flat blade screw driver (max. 2 mm/ 0.08” wide) to press down the spring-loaded terminals • Use a flat blade screw driver (max. 3.5 mm/ 0.14” wide) to unscrew and fasten the screw terminals 1. Lead the cable(s) through the cable gland(s) and gasket(s) (suitable for cable diameter 5-10 mm/ 0.2”-0.4”). For C1D2 installations, use the supplied C1D2 approved cable glands. Make sure the cable glands fit tightly. 2. Connect the cables according to your configuration. See the reverse of this guide for pinout, specifications and example configuration drawing. The RJ-45 connector of the LAN cable can pass through the standard cable gland. (see picture) 3. If you are not using PoE to power the EXPLORER 540, connect a power cable between the DC input terminals and a current-limited power supply or an external battery as described below. 4. When all cables are connected, mount the cover for the interface enclosure and tighten the screws with the included Torx bit. Important! If you only need to install one cable, mount the provided blanking plug in the unused hole to maintain the Ingress Protection (IP grade) of the terminal. To connect to the DC input: 1. Lead the cable through the cable gasket at the DC input. 2. If the DC cable is shielded, insert the end of the shield into the screw terminal marked 3-GND and tighten the screw to torque 0.5 N m/ 4.5 lbf in. 3. Insert the negative wire into the termi- nal marked 2-DCIN - in the DC terminal block and tighten the screw to torque 0.5 N m /4.5 lbf in. 4. Insert the positive wire into the terminal marked 1-DCIN + in the DC terminal block and tighten the screw to torque 0.5 N m/ 4.5 lbf in. 5. Tighten the cable gland. The following items are included in the delivery: • EXPLORER 540 terminal • Pole mount kit • 2 standard cable glands • 2 C1D2 approved cable glands • 1 Blanking plug • Torx bit Size TX10 (tamper resi- stant, 1/4” Hex drive) for mounting/ unmounting the cover for the interface enclosure • Installation guide (this guide) EXPLORER 540 User and integrator’s manual (part no. 98-148232) as well as other language versions of this installation guide are available for download at the Cobham SYNC Partner Portal. Go to www.cobham.com/satcom and select Cobham SYNC Partner Portal > Downloads. Caution! Do not connect the positive or negative wire to 3-GND! Pole size 1” to 1.5” (33.7 to 48.3 mm) Note: If the LED is steady yellow, it means the installation failed and there is a warning. If you can connect a computer locally to the EXPLORER 540, you can use the web interface to follow the progress on screen, see any warnings, and restart the installation if necessary. See Verifying and troubleshooting the installation on the back. Note: The installation will fail if the SIM card requires a user defined APN value and you have not yet entered this in the EXPLORER 540. Specify the APN value and restart the installation. For details, see the EXPLORER 540 User and integrator’s manual. 1. Attach the base of the pole mount bracket to the EXPLORER 540 using the included Hex L key on the 4 screws. Cau- tion! Max. length of the screws is 9 mm/ 0.35”! Longer screws can damage the EXPLORER 540. 2. Unscrew two of the long screws from the pole mount kit to leave one side open for the pole. 3. Place the pole mount kit with the EXPLORER 540 around the pole as shown. 4. Remount the two remaining long screws. Do not tighten the screws completely until you have pointed the antenna. 5. Power up the system. Observe the LED between the cable glands (see LED description on the back). • LED flashing rapidly green: Starting up • LED flashing yellow: Pointing • LED steady yellow: Warning! See Verifying and troubleshooting the installation on the back. 6. When LED flashes yellow: Turn and tilt the EXPLORER 540 and use the pointing sound to obtain the highest possible signal strength (continuous sound = best signal). 7. When you have the highest possible signal strength, tighten all the screws on the pole mount kit to keep the EXPLORER 540 in the pointed positionThe EXPLORER 540 will automatically exit the pointing process once it has detected a stable BGAN signal. 8. When the pointing process has ended, the LED changes as follows: • LED flashing green: Verifying network connection • LED steady green and then off: Ready - installation process has ended successfully. The LED is disabled (off) after a few minutes.

COBHAM EXPLORER 540 Installation manual [PDF] (2 pages)

  • Identifier: id-2014644
  • Brand: COBHAM
  • Device: EXPLORER 540 Touch terminals
  • Type: PDF
  • Key Aspects: Standard Operating Procedures, Control Panel and Interface Navigation, Unpacking and Inspection Guidelines
  • UPD Date: 08.04.2026
  • Source File: 2273214.pdf
  • Pages: 2
  • Description: Official user handbook for the COBHAM EXPLORER 540.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
What’s in the box? Step 2: Connect cables Step 3: Install the EXPLORER 540 EXPLORER 540 Installation guide Step 1: Insert SIM card If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Cleaning: Clean the exterior of the EXPLORER 540 with a damp cloth. X2: Ethernet, RJ-45 X1: Ethernet, Spring-loaded terminals X4: DC input, Screw terminals X5: I/O, Spring-loaded terminals X6: USB Micro B (in the side wall - not visible here) X7: Chassis GND, Screw terminal LED = LED = EXPLORER 540 terminal with pole mount kit Disclaimer: Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by Thrane & Thrane A/S. The information in this manual is provided for information purposes only, is subject to change without notice and may contain errors or inaccuracies. The manuals are periodically revised and updated. Anyone relying on this information should acquire the most current version e.g. from cobham. com/satcom or from the distributor. Thrane & Thrane A/S is not responsible for the content or accuracy of any translations or reproductions, in whole or in part, of this manual from any other source. Thrane & Thrane A/S trading as Cobham SATCOM. Copyright © 2019 Thrane & Thrane A/S. All rights reserved. Manufacturer address: Thrane & Thrane A/S, Lundtoftegaardsvej 93 D, DK-2800, Kgs. Lyngby, Denmark You need a BGAN SIM card for either BGAN M2M or BGAN class 2 services. To insert the SIM card, do as follows: NOTE: Make sure the EXPLORER 540 is not powered when you insert or remove the SIM card! 1. Open the cover for the interface enclosure at the back of the EXPLORER 540. Use the included Torx bit to unscrew the screws. 2. Locate the SIM holder in the middle of the compartment. 3. Slide the lock to release the SIM holder. 4. Lift the end of the SIM holder and insert the SIM card as shown. 5. Lower the SIM card holder with the SIM card inserted and lock it. 6. When all cables are connected, put the cover back on and tighten the screws. NOTE: Make sure the PIN for the SIM card is either disabled or set up for automatic valida- tion. For details, see the EXPLORER 540 User and integrator’s manual. A pole mount kit is included in the package. To mount the EXPLORER 540 on a pole, do as follows: To maintain the Ingress Protection rating of the EXPLORER 540 and to avoid cables acciden- tally being disconnected, all cable connections are made inside the interface enclosure at the back of the EXPLORER 540. Tools: • Use the provided Torx bit to open the interface enclosure at the back of the terminal • Use a flat blade screw driver (max. 2 mm/ 0.08” wide) to press down the spring-loaded terminals • Use a flat blade screw driver (max. 3.5 mm/ 0.14” wide) to unscrew and fasten the screw terminals 1. Lead the cable(s) through the cable gland(s) and gasket(s) (suitable for cable diameter 5-10 mm/ 0.2”-0.4”). For C1D2 installations, use the supplied C1D2 approved cable glands. Make sure the cable glands fit tightly. 2. Connect the cables according to your configuration. See the reverse of this guide for pinout, specifications and example configuration drawing. The RJ-45 connector of the LAN cable can pass through the standard cable gland. (see picture) 3. If you are not using PoE to power the EXPLORER 540, connect a power cable between the DC input terminals and a current-limited power supply or an external battery as described below. 4. When all cables are connected, mount the cover for the interface enclosure and tighten the screws with the included Torx bit. Important! If you only need to install one cable, mount the provided blanking plug in the unused hole to maintain the Ingress Protection (IP grade) of the terminal. To connect to the DC input: 1. Lead the cable through the cable gasket at the DC input. 2. If the DC cable is shielded, insert the end of the shield into the screw terminal marked 3-GND and tighten the screw to torque 0.5 N m/ 4.5 lbf in. 3. Insert the negative wire into the termi- nal marked 2-DCIN - in the DC terminal block and tighten the screw to torque 0.5 N m /4.5 lbf in. 4. Insert the positive wire into the terminal marked 1-DCIN + in the DC terminal block and tighten the screw to torque 0.5 N m/ 4.5 lbf in. 5. Tighten the cable gland. The following items are included in the delivery: • EXPLORER 540 terminal • Pole mount kit • 2 standard cable glands • 2 C1D2 approved cable glands • 1 Blanking plug • Torx bit Size TX10 (tamper resi- stant, 1/4” Hex drive) for mounting/ unmounting the cover for the interface enclosure • Installation guide (this guide) EXPLORER 540 User and integrator’s manual (part no. 98-148232) as well as other language versions of this installation guide are available for download at the Cobham SYNC Partner Portal. Go to www.cobham.com/satcom and select Cobham SYNC Partner Portal > Downloads. Caution! Do not connect the positive or negative wire to 3-GND! Pole size 1” to 1.5” (33.7 to 48.3 mm) Note: If the LED is steady yellow, it means the installation failed and there is a warning. If you can connect a computer locally to the EXPLORER 540, you can use the web interface to follow the progress on screen, see any warnings, and restart the installation if necessary. See Verifying and troubleshooting the installation on the back. Note: The installation will fail if the SIM card requires a user defined APN value and you have not yet entered this in the EXPLORER 540. Specify the APN value and restart the installation. For details, see the EXPLORER 540 User and integrator’s manual. 1. Attach the base of the pole mount bracket to the EXPLORER 540 using the included Hex L key on the 4 screws. Cau- tion! Max. length of the screws is 9 mm/ 0.35”! Longer screws can damage the EXPLORER 540. 2. Unscrew two of the long screws from the pole mount kit to leave one side open for the pole. 3. Place the pole mount kit with the EXPLORER 540 around the pole as shown. 4. Remount the two remaining long screws. Do not tighten the screws completely until you have pointed the antenna. 5. Power up the system. Observe the LED between the cable glands (see LED description on the back). • LED flashing rapidly green: Starting up • LED flashing yellow: Pointing • LED steady yellow: Warning! See Verifying and troubleshooting the installation on the back. 6. When LED flashes yellow: Turn and tilt the EXPLORER 540 and use the pointing sound to obtain the highest possible signal strength (continuous sound = best signal). 7. When you have the highest possible signal strength, tighten all the screws on the pole mount kit to keep the EXPLORER 540 in the pointed positionThe EXPLORER 540 will automatically exit the pointing process once it has detected a stable BGAN signal. 8. When the pointing process has ended, the LED changes as follows: • LED flashing green: Verifying network connection • LED steady green and then off: Ready - installation process has ended successfully. The LED is disabled (off) after a few minutes.

COBHAM EXPLORER 540 Installation manual [PDF] (2 pages)

  • Identifier: id-895964
  • Brand: COBHAM
  • Device: EXPLORER 540 Touch terminals
  • Type: PDF
  • Key Aspects: Risk Mitigation and Accident Prevention, Information on Regular Maintenance, Manufacturer Contact and Support Data
  • UPD Date: 10.08.2026
  • Source File: 848593.pdf
  • Pages: 2
  • Description: Product documentation for the COBHAM EXPLORER 540.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
What’s in the box? To maintain the Ingress Protection of the EXPLORER 540 and to avoid cables accidentally being disconnected, all cable connections are made inside the small compartment at the back of the EXPLORER 540. •� Use the provided Torx bit to open the small compartment at the back of the terminal. •� Use�a�flat�blade�screw�driver�(max.�2�mm�wide)�to�press�down�the� spring-loaded terminals. •� Use�a�flat�blade�screw�driver�(max.�3.5�mm�wide)�to�unscrew�and�fasten� the�screw�terminals. 1. Lead�the�cable(s)�through�the�cable�gland(s)�and�gasket(s)�(suitable�for� cable�diameter�5-10�mm).�Make�sure�the�cable�glands�fit�tightly. 2.� Connect the cables accor- ding�to�your�configuration.� See�the�reverse�of�this�guide� for�pinout�and�example�con- figuration�drawing. The RJ-45 connector of the LAN�cable�can�pass�through� the�cable�gland.�(see�picture) 3.� If�you�are�not�using�PoE�to� power�the�EXPLORER�540,� connect�a�power�cable� between�the�DC�input�terminals�and�an�external�battery�or�power�supply. 4. When�all�cables�are�connected,�mount�the�cover�for�the�compartment� and�tighten�the�screws�with�the�included�Torx�bit. Important!�If�you�only�need�to�install�one�cable,�mount�the�provided�blind� plug�in�the�unused�hole�to�maintain�the�Ingress�Protection�(IP�grade)�of�the� terminal. Step 2: Connect cables Step 3: Install the EXPLORER 540 The�following�items�are�included�in�the� delivery: •� EXPLORER 540 terminal •� Pole�mount�kit •� 2�Cable�glands�and�1�Blind�plug •� Torx�bit�Size�TX10�(tamper� resistant,�1/4”�Hex�drive)�for� mounting/dismounting�the�cover� for the small compartment •� Installation�guide�(this�guide)� EXPLORER�540�User�and�integrator’s�manual�(part�no.�98-148232)�as�well� as�other�language�versions�of�this�installation�guide�are�available�for�down- load�at�the�Self�Service�Center.�Go�to�www.cobham.com/satcom�and�select� Service�and�Support�>�Cobham�SATCOM�Service�and�Support�>�24-7�Self� Service�Center�/�Technical�Downloads. A�pole�mount�kit�is�included�in�the�delivery.�To�mount�the�EXPLORER�540�on� a�pole,�do�as�follows: 1. Attach�the�base�of�the�pole�mount�bracket�to�the�EXPLORER�540�using� the�included�Hex�L�key�on�the�4� screws.�Caution! Max.�length�of�the� screws�is�9�mm!�Longer�screws�can� damage the EXPLORER 540. 2.� Unscrew�two�of�the�long�screws�from� the�pole�mount�kit�to�leave�one�side� open for the pole. 3.� Place�the�pole�mount�kit�with�the� EXPLORER�540�around�the�pole�as� shown. 4. Remount�the�two�remaining�long� screws.�Do�not�tighten�the�screws� completely�until�you�have�pointed� the antenna. 5. Power�up�the�system. Observe�the�LED�between�the�cable� glands�(see�LED�description�on�the� back).� •� LED�flashing�rapidly�green:� Starting�up •� LED�flashing�yellow:�Pointing •� LED�steady�yellow:�Warning!� See Verificaton on the back. 6. When�LED�flashes�yellow:�Turn�and� tilt�the�EXPLORER�540�and�use�the� pointing�sound�to�obtain�the�highest� possible�signal�strength.�(continuous� sound�=�best�signal)� 7.� When�you�have�the�highest�possible� signal�strength.�tighten�all�the�screws� to keep the EXPLORER 540 in the pointed position. The�EXPLORER�540�will�automatically� exit the pointing process once it has detected�a�stable�BGAN�signal. 8.� When the pointing process has en- ded,�the�LED�changes�as�follows: •� LED�flashing�green:�Verifying�network�connection •� LED�steady�green�and�then�off:�Ready�-�installation�process�has�ended� successfully.�The�LED�is�disabled�(off)�after�a�few�minutes. If�the�LED�is�steady�yellow,�the�installation�failed�and�there�is�a�warning. If�you�can�connect�a�computer�locally�to�the�EXPLORER�540,�you�can�use�the� web�interface�to�follow�the�progress�on�screen,�see�any�warnings,�and�restart� the installation if necessary. See Verification on the back. EXPLORER 540 Installation guide You�need�a�BGAN�SIM�card�for�either�M2M�or�standard�class�2�services.�To� insert�the�SIM�card,�do�as�follows: NOTE:�Make�sure�the�EXPLORER�540� is not�powered�when�you�insert�or� remove�the�SIM�card! 1. Open the cover for the small com- partment at the back of the EXPLO- RER�540.�Use�the�included�Torx�bit� to�unscrew�the�screws.� 2.� Locate�the�SIM�holder�in�the� middle of the compartment. 3.� Slide�the�lock�to�release�the�SIM� holder. 4. Lift�the�end�of�the�SIM�holder�and� insert�the�SIM�card�as�shown. 5. Lower�the�SIM�card�holder�with� the�SIM�card�inserted�and�lock�it. 6. When�all�cables�are�connected,�put� the cover back on and tighten the screws.� Step 1: Insert SIM card Disclaimer: Any responsibility or liability for loss or damage in connection with the use of this product and the accompanying documentation is disclaimed by Thrane & Thrane A/S. The information in this manual is provided for information purposes only, is subject to change without notice and may contain errors or inaccuracies. The manuals are periodically revised and updated. Anyone relying on this information should acquire the most current version e.g. from cobham.com/satcom or from the distributor. Thrane & Thrane A/S is not responsible for the content or accuracy of any translations or reproductions, in whole or in part, of this manual from any other source. Thrane & Thrane A/S trading as Cobham SATCOM. Copyright © 2016 Thrane & Thrane A/S. All rights reserved. X2:�Ethernet, RJ-45 X1: Ethernet, Spring-loaded terminals X4:�DC�input, Screw�terminals X5: I/O, Spring-loaded terminals X6:�USB�Micro�B (in�the�side�wall�-� not�visible�here) EXPLORER 540 terminal with pole mount kit X7:�Chassis�GND,� Screw�terminal LED�= LED�=

COBHAM EXPLORER 540 Setup manual [PDF] (5 pages)

  • Identifier: id-846273
  • Brand: COBHAM
  • Device: EXPLORER 540 Conference System
  • Type: PDF
  • Key Aspects: User Training Recommendations, Model Variations and Compatibility, Risk Mitigation and Accident Prevention
  • UPD Date: 13.03.2026
  • Source File: 898303.pdf
  • Pages: 5
  • Description: Complete instruction guide for the COBHAM EXPLORER 540.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Pivotel Setup Guide for Cobham Explorer 540

COBHAM EXPLORER 540 User & integrator's manual [PDF] (172 pages)

  • Identifier: id-1492893
  • Brand: COBHAM
  • Device: EXPLORER 540 Antenna
  • Type: PDF
  • Key Aspects: Critical Operational Precautions, Common Issue Diagnostic Flows, Emergency Shutdown Procedures
  • UPD Date: 22.08.2026
  • Source File: 1505536.pdf
  • Pages: 172
  • Description: Professional user manual for the COBHAM EXPLORER 540.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
EXPLORER 540 User & integrator’s manual

COBHAM EXPLORER 540 Operation & user’s manual [PDF] (134 pages)

  • Identifier: id-885642
  • Brand: COBHAM
  • Device: EXPLORER 540 Touch terminals
  • Type: PDF
  • Key Aspects: Storage and Care Recommendations, Emergency Shutdown Procedures, Glossary of Technical Terms
  • UPD Date: 29.04.2026
  • Source File: 858916.pdf
  • Pages: 134
  • Description: Technical operations guide for the COBHAM EXPLORER 540.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
EXPLORER 540 User & integrator’s manual

EXPLORER 540: Related Instructions

Sea Tel 2400
COBHAM Sea Tel 2400
28.08.2026 120 pages

EAR Controlled - ECCN EAR99 This technical data is subject to US Government export control in accordance with the Export Administration Regulations. Export Instruction guidebook for the COBHAM Sea Tel 2400 Antenna. This reference includes warranty information, troubleshooting guides, operation, operating modes.

Messenger VETA
COBHAM Messenger VETA
21.07.2026 36 pages

User guidebook for the COBHAM Messenger VETA Receiver. The guide covers usage and setup, usage examples, installation.

EXPLORER 122
COBHAM EXPLORER 122
20.06.2026 11 pages

EXPLORER 122 Quick start guide User support manual for the COBHAM EXPLORER 122 Touch terminals. It contains information on product specifications, device overview, operational guidelines.

Sailor 150 FleetBroadband
COBHAM Sailor 150 FleetBroadband
25.07.2026 2 pages

SAILOR 150 FleetBroadband Quick Guide Make a voice call To make a call from your SAILOR FleetBroadband terminal, dial 00 # Example Device maintenance guide for the COBHAM Sailor 150 FleetBroadband Marine GPS System. This reference manual outlines product handling, technical assistance, configuration options.

SAILOR 600 Viasat Ka
COBHAM SAILOR 600 Viasat Ka
11.08.2026 144 pages

Cobham Public SAILOR 600 Viasat Ka Installation and operation manual Technical instruction manual for the COBHAM SAILOR 600 Viasat Ka Antenna. It offers details on daily usage, safety, warranty information, application scenarios.

DIGImini Series
COBHAM DIGImini Series
26.08.2026 81 pages

Cobham Wireless – Coverage Date: 11-Oct-15 www.cobham.com/wireless Document number: 00030UMCD Rev. 5.0 Page | I The most important thing we build is trust DIG Reference manual for the COBHAM DIGImini Series Repeater. The manual covers procedures for device operation tips, maintenance guidelines, basic operation.

Similar Manuals in the Antenna, Conference System, Touch terminals Category

GL-11
VisionTek GL-11
08.05.2026 2 pages

Practical operating guide for the VisionTek GL-11 Touch terminals. The manual provides information on calibration steps, firmware updates, maintenance schedule, error codes.

VZ7656R1000W
Viconics VZ7656R1000W
09.07.2026 31 pages

1 | 028-0323-02_LIT-VZ7656R&VZ7656H_W-E01_EN www.viconics.com September 2019 CONTENTS Safety Information 2 Before You Begin 3 Installation 5 Theory of Operation Instruction guidebook for the Viconics VZ7656R1000W Touch terminals. It explains installation, setup, and repair references, product safety, troubleshooting guides, setup guidelines.

CT40 HomeBase
Honeywell CT40 HomeBase
06.07.2026 8 pages

CT40 HomeBase Model CT40-HB, CT40-EB Quick Start Guide CT40-EHB-EN-QS Rev A 08/18 Comprehensive guide for the Honeywell CT40 HomeBase Touch terminals. The manual includes instructions for hardware components, maintenance guidelines, component overview.

DS-K1T680 Series
HIKVISION DS-K1T680 Series
27.08.2026 2 pages

DS-K1T680 Series Face Recognition Terminal Quick Start Guide ©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The M Operation guide for the HIKVISION DS-K1T680 Series Touch terminals. It explains usage scenarios and diagnostic information, menu navigation, setup instructions.