Cooper Lighting C900 Manuals

1 pdf manual(s) Cooper Lighting C900 for free download (Document Types: Specification sheet)

Document Preview & Text Transcription

DESCRIPTION Catalog # Type Project Comments Date Prepared by www.cooperlighting.com SPECIFICATION FEATURES A....Housing Shallow low voltage recessed fixture housing for insulated ceiling installations. Includes integral low voltage magnetic transformer. All aluminum construction. 14 ga. steel junction box. B....Electrical Socket is pre-wired to the j-box 18AWG SF-1 leads. Primary lead is 120V or 277V. Transformer is rated 180˚ Class H. State of Washington AirTite approved. C....Mounting Provided with two (2) adjustable 16 ga. steel hanger bars which can be extended to 25.25”. D....System Protection Transformers have thermal protection and operate at 11.5 volts nominal. Ceiling Cut-Out: 3.75” dia. MICROGEM SHALLOW HOUSING C900 Insulated Ceiling AirTite Shallow Housing w/ Integral Low Voltage Transformer FOR 12V LAMP 50W max. ORDERING INFORMATION Shallow insulated ceiling AirTite (I.C.) Microgem recessed low voltage housing with integral magnetic transformer 50W max. 120V or 277V. For use in insulated ceiling (I.C.) applications. Housing may be covered on all sides with insulation material. Specifications and Dimensions subject to change without notice. RSA Lighting • 7945 Orion Ave. • Van Nuys, CA 91406 • 818-349-3030 • FAX 818-349- 3031 rev. 102406 Housing C900 = Microgem shallow insulated ceiling low voltage recessed housing. 3.75" 20.125" 18.125" 15.188" 13.25" 14.13" 5.5" 14" min. 25.25" max. A D C B C900 Voltage 120 = 120 volts primary 277 = 277 volts primary