Series SA-S70-24MCW-FR Series SA-S90-24MCC-FR Series SA-S70-R Features: • Approvals Include: UL Standard 1480 (Speakers) and UL Standard 1971 and UL Standard 1480 (Speaker Strobes) • Accepts audio input levels of 0.5 VRMS or 25 VRMS • Power Input Voltage 16.0 to 33.0 VDC • Wall or ceiling mount models • Speaker strobes utilize Wheelock’s synchronizable Multi- Candela Strobe • 1 watt high efficiency speaker • Frequency range of 400Hz to 4000Hz • Mounts onto a 4” square deep backbox with an extension ring Power Input Voltage: 16.0-33.0 VDC, regulated Appliance Input Level: 0.5 V RMS or 25 V RMS (Switch selectable) Appliance Input Impedence: 0.5-V Setting: Greater than 400 Ohms, or equivalent to less than 1/1000 W (0.001 W or 1 mW) load 25-V Setting: Greater than 20 kOhms, or equivalent to less than 1/32 W (.03125 W or 31.25 mW) load Sound Level Speaker Amplifier Current Draw: (Loudest) Level 6: < 120mA RMS Level 5: < 97mA RMS Level 4: < 80mA RMS Level 3: < 68mA RMS Level 2: < 60mA RMS (Lowest) Level 1: < 54mA RMS dB Sound Output Sound Level SA-S90R SA-S90W SA-S70R SA-S70W SA-S90-24MCC-FR SA-S90-24MCC-FW SA-S70-24MCC-FR SA-S70-24MCC-FW 6 84 84 82 5 82 81 81 4 77 77 76 3 75 74 74 2 71 71 70 1 69 68 68 Description: The Series SA-S Supervised Self-Amplified Speakers and Speaker Strobes are designed to meet the critical needs for the life safety industry. These speakers and speaker strobes are a perfect fit for SCIF (Sensitive Compartmented Information Facilities) room applications. UL ® S5391 Series SA-S Supervised Self-Amplified Speakers and Speaker Strobes
Series SA-S70-24MCW-FR: Related Instructions
P84762 B Sheet 1 of 3 273 Branchport Ave. Long Branch, N.J. 07740 Thank you for using our products. (800) 631-2148 (800) 397-5777 INSTALLATION INSTRUCTIONS Full operation manual for the Cooper Wheelock WFP Smoke Alarm. The guide explains operation and energy usage, user settings, technical overview.
Description: These certified strobes have been designed for use in poten- tially explosive gas and dust atmospheres and harsh environ- mental conditions. The Complete instruction guide for the Cooper Wheelock XB11 Smoke Alarm. The documentation guides users through setup and dimensions and layout, hardware setup, network setup, system parameters.
Description: The Wheelock Series STH Cluster Speaker with MCCH Multi- Candela Strobe is designed for indoor ceiling mounting in high ambient noise environments Technical operations guide for the Cooper Wheelock STH-4R24MCCH-NR Speakers. This guide elaborates on device features and safety guidelines, error handling, technical specifications.
Features • Approvals include: UL Standard 1480 – (Speakers for Fire Protective Signaling Systems), California State Fire Marshal (CSFM) Title 19 • Meets Operating instructions for the Cooper Wheelock STH-15S Speakers. This manual provides information on operating instructions, power requirements, installation guides.
Description: This range of light weight, flameproof horns has been designed with a high weatherproof rating to cope with the harsh environmental conditions fou Comprehensive guide for the Cooper Wheelock DB1 Horn. It explains installation, setup, and software configuration, device safety checks, menu navigation.
Description: Features: The Wheelock Series Z notification appliances feature an easy snap on base that is designed to simplify the installation and testing of Professional manual for the Cooper Wheelock Series ZNS Smoke Alarm. It describes operating procedures and product maintenance, compatibility information, configuration options, troubleshooting guides.
Similar Manuals in the Smoke Alarm Category
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27 [email protected] • WWW.LST.AT • A Operation instructions for the LST MM-55000-833 Smoke Alarm. It explains operation, maintenance, and service instructions, system setup, control functions, service contacts.
D200-68-00 1 I56-1144-04 2100TR Photoelectronic Smoke Detector with Fixed Heat INSTALLATION AND MAINTENANCE INSTRUCTIONS A Division of Pittway 3825 Ohio Avenue User instruction booklet for the Pittway System Sensor 2100TR Smoke Alarm. This manual provides information on firmware installation, service instructions, menu navigation.
HTTP://WWW.HOMBI.RU 30302077 Issue 1.05 Features Alarming by pressing, reset User guide for the GST C-9202 Safety Equipment. It details operating modes and device instructions, safety information, detailing setup.
Battery Operated COMBINATION SMOKE & CARBON MONOXIDE ALARM User’s Guide With 2-LED Display, HUSH® and Peak Level Memory Model: KN-COSM-BCA Manual P/N 810-133 Device operation guide for the Kidde KN-COSM-BCA Smoke Alarm. The manual elaborates on features and technical troubleshooting, power requirements, maintenance schedule, daily usage.