3/4 HP
GARAGE DOOR OPENER
ABRIDOR DE PUERTA DE COCHERA DE
For Residential Use Only/Sólo para uso residencial
Model/Modelo • 139.53990DS
®
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A
www.sears.com/craftsman
Owner’s Manual/Manual Del Propietario
ENGLISH ESPAÑOL
Read and follow all safety rules
and operating instructions before
first use of this product.
Fasten the manual near the
garage door after installation.
Periodic checks of the opener are
required to ensure safe operation.
Leer y seguir todas las reglas de
seguridad y las instrucciones de
operación antes de usar este
producto por primera vez.
Guardar este manual cerca de la
puerta de la cochera.
Se deben realizar revisiones
periódicas del abridor de puertas
para asegurar su operación
segura.
2
TABLE OF CONTENTS
When you see these Safety Symbols and Signal
Words on the following pages, they will alert you to
the possibility of serious injury or death if you do
not comply with the warnings that accompany them.
The hazard may come from something mechanical
or from electric shock. Read the warnings carefully.
When you see this Signal Word on the following
pages, it will alert you to the possibility of damage to
your garage door and/or the garage door opener if
you do not comply with the cautionary statements
that accompany it. Read them carefully.
INTRODUCTION
Safety Symbol
and Signal Word Review
This garage door opener has been designed and tested to offer safe service provided it is installed, operated,
maintained and tested in strict accordance with the instructions and warnings contained in this manual.
Mechanical
Electrical
Introduction
2-7
Safety symbol and signal word review ....................... 2
Preparing your garage door ....................................... 3
Tools needed .............................................................. 3
Planning ................................................................. 4-5
Carton inventory ......................................................... 6
Hardware inventory .................................................... 7
Assembly
8-11
Assemble the rail and install the trolley...................... 8
Fasten the rail to the motor unit and
install the idler pulley .................................................. 9
Install the chain/cable ............................................... 10
Tighten the chain .......................................................11
Installation
11-26
Installation safety instructions ...................................11
Determine the header bracket location .................... 12
Install the header bracket ......................................... 13
Attach the rail to the header bracket ........................ 14
Position the opener .................................................. 15
Hang the opener....................................................... 16
Install the door control .............................................. 17
Install the lights......................................................... 18
Attach the emergency release rope and handle ...... 18
Electrical requirements ............................................. 19
Install The Protector System® .............................. 20-22
Fasten the door bracket ...................................... 23-24
Connect the door arm to the trolley..................... 25-26
Adjustment
27-29
Adjust the travel limits .............................................. 27
Adjust the force ........................................................ 28
Test the safety reversal system ................................ 29
Test The Protector System® ...................................... 29
Operation
30-34
Operation safety instructions .................................... 30
Using your garage door opener ............................... 30
Using the wall-mounted Door Control ...................... 31
To open the door manually ....................................... 31
Care of your garage door opener ............................. 32
Having a problem? ................................................... 33
Diagnostic chart ........................................................ 34
Programming
35-36
To add or reprogram a hand-held remote control .... 35
To erase all codes .................................................... 35
3-Function Remotes ................................................. 35
To add, reprogram or change
a Keyless Entry PIN ................................................. 36
Repair Parts
37-38
Rail assembly parts .................................................. 37
Installation parts ....................................................... 37
Motor unit assembly parts ........................................ 38
Accessories
39
Warranty
39
Repair Parts
and Service
Back Cover
3
To prevent damage to garage door and opener:
• ALWAYS disable locks BEFORE installing and
operating the opener.
• ONLY operate garage door opener at 120V, 60 Hz to
avoid malfunction and damage.
To prevent possible SERIOUS INJURY or DEATH:
• ALWAYS call a trained door systems technician if
garage door binds, sticks, or is out of balance. An
unbalanced garage door may NOT reverse when
required.
• NEVER try to loosen, move or adjust garage door, door
springs, cables, pulleys, brackets or their hardware,
ALL of which are under EXTREME tension.
• Disable ALL locks and remove ALL ropes connected to
garage door BEFORE installing and operating garage
door opener to avoid entanglement.
Preparing your garage door
Before you begin:
• Disable locks.
• Remove any ropes connected to garage door.
• Complete the following test to make sure your
garage door is balanced and is not sticking or
binding:
1. Lift the door about halfway as shown. Release
the door. If balanced, it should stay in place,
supported entirely by its springs.
2. Raise and lower the door to see if there is any
binding or sticking.
If your door binds, sticks, or is out of balance, call a
trained door systems technician.
Tools needed
During assembly, installation and adjustment of the
opener, instructions will call for hand tools as
illustrated below.
Sectional Door
One-Piece Door
Pliers
Wire Cutters
Claw Hammer
Hack Saw
Screwdriver
Adjustable End Wrench
Sockets and Wrench
1/2", 5/8", 7/16", 9/16"
and 1/4"
Drill
Tape Measure
2
1
Stepladder
Pencil
Drill Bits
3/16", 5/16"
and 5/32"
Carpenter's
Level (optional)
4
Safety Reversing Sensor
Header Wall
Access Door
— — — — — — — —
Safety Reversing Sensor
Gap between floor
and bottom of door
must not exceed 1/4" (6 mm).
Extension Spring
Horizontal and vertical reinforcement
is needed for lightweight garage doors
(fiberglass, steel, aluminum, door with
glass panels, etc.). See page 23 for details.
Support bracket &
fastening hardware
is required.
See page 16.
FINISHED CEILING
Motor unit
Wall-mounted
Door Control
OR
Torsion Spring
Slack in chain tension
is normal when
garage door is closed.
Vertical
Centerline
of Garage
Door
SECTIONAL DOOR INSTALLATION
Planning
Identify the type and height of your garage door.
Survey your garage area to see if any of the
conditions below apply to your installation. Additional
materials may be required. You may find it helpful to
refer back to this page and the accompanying
illustrations as you proceed with the installation of
your opener.
Depending on your requirements, there are several
installation steps which may call for materials or
hardware not included in the carton.
• Installation Step 1 – Look at the wall or ceiling
above the garage door. The header bracket must
be securely fastened to structural supports.
• Installation Step 5 – Do you have a finished ceiling
in your garage? If so, a support bracket and
additional fastening hardware may be required.
• Installation Step 10 – Depending upon garage
construction, extension brackets or wood blocks
may be needed to install sensors.
• Installation Step 10 – Alternate floor mounting of
the safety reversing sensor will require hardware
not provided.
• Do you have an access door in addition to the
garage door? If not, Model 53702 Emergency Key
Release is required. See Accessories page.
• Look at the garage door where it meets the floor.
Any gap between the floor and the bottom of the
door must not exceed 1/4" (6 mm). Otherwise, the
safety reversal system may not work properly. See
Adjustment Step 3. Floor or door should be
repaired.
SECTIONAL DOOR INSTALLATIONS
• Do you have a steel, aluminum, fiberglass or glass
panel door? If so, horizontal and vertical
reinforce ment is required (Installation Step 11).
• The opener should be installed above the center of
the door. If there is a torsion spring or center
bearing plate in the way of the header bracket, it
may be installed within 4 feet (1.22 m) to the left or
right of the door center. See Installation Steps 1
and 11.
• If your door is more than 7 feet (2.13 m) high, see
rail extension kits listed on Accessories page.
Header
Wall
Rail Tab
Trolley
Chain
Rail
Garage
Door
Spring
Emergency
Release
Rope &
Handle
Header
Bracket
Door
Bracket
Straight
Door Arm
Curved
Door Arm
Garage
Door
CLOSED POSITION
Pages Preview: