CREE LIGHTING KBL Series Manuals

3 pdf manual(s) CREE LIGHTING KBL Series for free download (Document Types: Installation instructions, Installation instructions manual)

CREE LIGHTING KBL Series Installation instructions [PDF] (5 pages)

  • Identifier: id-1738222
  • Brand: CREE LIGHTING
  • Device: KBL Series Lantern
  • Type: PDF
  • Key Aspects: Emergency Shutdown Procedures, Package Contents and Accessories List, Regulatory Compliance and Standards
  • UPD Date: 04.04.2026
  • Source File: 1802060.pdf
  • Pages: 5
  • Description: Quick reference guide for the CREE LIGHTING KBL Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
KBL Series Highbay LED Luminaire with Emergency Driver Universal Hook and Cord or Pendant Mount 1 of 5 LPN00627X0001A1_D INSTALLATION INSTRUCTIONS INSTRUCTIONS D’INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER- Risk of shock- Disconnect power before installation. DANGER - RISQUE DE CHOC - COUPER L’ALIMENTATION AVANT L’INSTALLATION 2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié. 3. To reduce the risk of electric shock, disconnect both standard and emergency power supplies and converter connector of the emergency driver before servicing. Pour réduire le risque de décharge électrique, vous devez déconnecter à la fois le disjoncteur divisionnaire ou les fusibles et les alimentations d’urgence avant l’entretien. 4. Do not use outdoors. Ne pas utiliser à l’extérieur. 5. Do not let power supply cords touch hot surfaces. Ne laissez pas les cordons d’alimentation toucher les surfaces chaudes. 6. Do not mount near gas or electric heaters. Ne montez PAS près des appareils de chauffage de gaz ou électriques. 7. Equipment should be mounted in locations and heights where it will not readily be subjected to tampering by unauthorized personnel. L’équipement doit être monté dans des endroits et à des hauteurs où il ne sera pas soumis à des altérations par des personnes non autorisées. 8. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. L’utilisation d’accessoires non recommandés par le fabricant peut causer une situation dangereuse. 9. Suitable for damp location. Convient aux emplacements humides. 10. Maximum ambient operating temperature: 9L, 12L, and 18L(M) = 50°C and 24L, 25L (H), and 30L= 40°C. Température ambiante maximale de fonctionnement: 9L, 12L, and 18L (M) = 50°C and 24L, 25L(H), and 30L= 40°C. 11. MIN 90°C SUPPLY CONDUCTORS LES FILS D’ALIMENTATION 90°C MIN. 12. Check to make sure that all input power connections have been properly made and the module is grounded to avoid potential electrical shock. 13. DO NOT lift luminaire by the cord. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE NOTES: • For each mounting application below, when mounting to surface ensure that the mounting surface and customer supplied hardware is capable of supporting the weight of the luminaire. • The center of mounting is NOT the same as the center of luminaire. Maximum Mounting Height in Feet Lumen output With prismatic diffuser With prismatic diffuser and conic lens 9L-12L 30 23 18L-30L 44 33

CREE LIGHTING KBL Series Installation instructions manual [PDF] (6 pages)

  • Identifier: id-1451546
  • Brand: CREE LIGHTING
  • Device: KBL Series Lantern
  • Type: PDF
  • Key Aspects: Safety Recommendations and Warnings, Initial Startup Checklist, Control Panel and Interface Navigation
  • UPD Date: 24.05.2026
  • Source File: 1546896.pdf
  • Pages: 6
  • Description: Device user manual for the CREE LIGHTING KBL Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
KBL Series LED Luminaire Universal Hook and Cord or Pendant Mount 1 of 6 LPN00513X0001A4_D INSTALLATION INSTRUCTIONS INSTRUCTIONS D’INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER- Risk of shock- Disconnect power before installation. DANGER – Risque de choc – Couper l’alimentation avant l’installation. 2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié. 3. Suitable for damp location. Convient aux emplacements humides. 4. Maximum ambient operating temperature: 9L, 12L, 18L (M) = 50°C and 24L (H), and 30L= 40°C. Température ambiante maximale de fonctionnement: 9L, 12L, 18L (M) = 50°C et 24L (H), et 30L= 40°C. 5. MIN 90°C SUPPLY CONDUCTORS LES FILS D’ALIMENTATION 90°C MIN. 6. Check to make sure that all input power connections have been properly made and the module is grounded to avoid potential electrical shock. 7. DO NOT lift luminaire by the power cord or any of the cables connected to the LED heatsink and LED driver. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE NOTES: • Images used in this installation sheet are for illustration purpose, there are different configurations of the luminaire. • For each mounting application below, when mounting to surface ensure that the mounting surface and customer supplied hardware is capable of supporting the weight of the luminaire. • The center of mounting is NOT the same as the center of luminaire. TO INSTALL: HOOK AND CORD MOUNT STEP 1: Push down on retainer spring until top of spring is free of luminaire hook. See Figure 1. STEP 2: Slide hook into securely mounted customer supplied eye hanger and return retainer spring to original position. NOTE: The luminaire should already be factory set for correct balance. If necessary, the fixture may be balanced by loosening the hook adjustment screws on the top of the housing and sliding the hook as necessary for correct balance. Tighten hook adjustment screws when finished. See Figure 1. STEP 3: Make wiring connections per the Electrical Connections section. After electrical connections for luminaires with a sensor go to pages 4-6 for installation of sensor. 1 Luminaire Hook Hook Adjustment Screws Retainer Spring 1/2” (13mm) IP, 0.875” (22mm) O.D. Knockout KBL KBL WITH ML SENSOR KBL WITH PML SENSOR

CREE LIGHTING KBL Series Installation instructions manual [PDF] (8 pages)

  • Identifier: id-2032350
  • Brand: CREE LIGHTING
  • Device: KBL Series Lantern
  • Type: PDF
  • Key Aspects: Critical Operational Precautions, Initial Startup Checklist, Component Overview and Descriptions
  • UPD Date: 23.08.2026
  • Source File: 2255508.pdf
  • Pages: 8
  • Description: Detailed operating instructions for the CREE LIGHTING KBL Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
KBL Series Wireless Highbay LED Luminaire with Emergency Driver Universal Hook and Cord or Pendant Mount with Sensor 1 of 8 LPN00814X0001A0_D INSTALLATION INSTRUCTIONS INSTRUCTIONS D’INSTALLATION NOTES: • For each mounting application below, when mounting to surface ensure that the mounting surface and customer supplied hardware is capable of supporting the weight of the luminaire. • The center of mounting is NOT the same as the center of luminaire. • Images used in this installation sheet are for illustration purpose, there are different configurations of the luminaire. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER- Risk of shock- Disconnect power before installation. DANGER - RISQUE DE CHOC - COUPER L’ALIMENTATION AVANT L’INSTALLATION 2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié. 3. To reduce the risk of electric shock, disconnect both standard and emergency power supplies and converter connector of the emergency driver before servicing. Pour réduire le risque de décharge électrique, vous devez déconnecter à la fois le disjoncteur divisionnaire ou les fusibles et les alimentations d’urgence avant l’entretien. 4. Do not use outdoors. Ne pas utiliser à l’extérieur. 5. Do not let power supply cords touch hot surfaces. Ne laissez pas les cordons d’alimentation toucher les surfaces chaudes. 6. Do not mount near gas or electric heaters. Ne montez PAS près des appareils de chauffage de gaz ou électriques. 7. Equipment should be mounted in locations and heights where it will not readily be subjected to tampering by unauthorized personnel. L’équipement doit être monté dans des endroits et à des hauteurs où il ne sera pas soumis à des altérations par des personnes non autorisées. 8. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. L’utilisation d’accessoires non recommandés par le fabricant peut causer une situation dangereuse. 9. Suitable for damp location. Convient aux emplacements humides. 10. Maximum ambient operating temperature: 18L = 50°C and 24L, 25L, and 30L= 40°C. Température ambiante maximale de fonctionnement: 18L = 50°C and 24L, 25L, and 30L= 40°C. 11. MIN 90°C SUPPLY CONDUCTORS LES FILS D’ALIMENTATION 90°C MIN. 12. Check to make sure that all input power connections have been properly made and the module is grounded to avoid potential electrical shock. 13. This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body. L’équipement doit etre installe d’une facon qu’une distance minimum de 20cm soit maintenue entre l’emetteur et toute partie du corps. 14. Check to make sure that all input power connections have been properly made and the module is grounded to avoid potential electrical shock. 15. DO NOT lift luminaire by the power cord or any of the cables connected to the LED heatsink and LED driver. 16. All electrical connections for the sensor have been made at the factory. 17. The sensor is designed for mounting heights between 8 ft. to 40 ft. (2.4 m to 12.2 m). The handheld remote unit has a range of up to 40ft (12.2 m). 18. When mounting heights are above 30ft. (9.1 m), the sensor generally only detects large objects such as forklift trucks. 19. When the sensor lens assembly is removed the exposed sensor body is sensitive to electrostatic discharge. Take the necessary steps to avoid possible damage to the sensor. 20. Use Class 1 Wiring methods ONLY 21. DO NOT lift luminaire by the cord. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE KBL EB WIRELESS KBL EB WIRELESS WITH NETWORK SENSOR Maximum Mounting Height in Feet Lumen output With prismatic diffuser With prismatic diffuser and conic lens 18L-30L 44 33