CREE LIGHTING Noctura Series Manuals

3 pdf manual(s) CREE LIGHTING Noctura Series for free download (Document Types: Installation instructions, Installation instructions manual)

CREE LIGHTING Noctura Series Installation instructions [PDF] (2 pages)

  • Identifier: id-1884326
  • Brand: CREE LIGHTING
  • Device: Noctura Series Lighting Equipment
  • Type: PDF
  • Key Aspects: FAQ Section for Common Queries, Component Longevity Optimization, Documentation and Revision History
  • UPD Date: 30.05.2026
  • Source File: 1838436.pdf
  • Pages: 2
  • Description: Service and user manual for the CREE LIGHTING Noctura Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Noctura Series LED Area Lights Bird Spikes INSTALLATION INSTRUCTIONS INSTRUCTIONS D’INSTALLATION 1 of 1 LPN00636X0001A0_B www.creelighting.com © 2019 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content is subject to change. See www.creelighting.com/warranty for warranty and specifications. Cree® and the Cree logo are registered trademarks of Cree, Inc. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER- Risk of shock- Disconnect power before installation. DANGER – Risque de choc – Couper l’alimentation avant l’installation. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE TO INSTALL: INSTALLATION STEP 1: Remove the (4) Phillips head screws on the back of the luminaire and discard screws. See Figure 1. STEP 2: Locate the bird spike frame on the back of the luminaire, aligning the screws included with the bird spike accessory with the holes in luminaire. Tighten screws to 20 in-lbs (2.2 N·m) 1 Remove the (4) Screws NTA (11L) NTA (19L) NTA (35L) Remove the (4) Screws Remove the (4) Screws

CREE LIGHTING Noctura Series Installation instructions manual [PDF] (6 pages)

  • Identifier: id-1884328
  • Brand: CREE LIGHTING
  • Device: Noctura Series Flood Light
  • Type: PDF
  • Key Aspects: Error Code Explanations, System Connectivity and Wiring Basics, Regulatory Compliance and Standards
  • UPD Date: 17.08.2026
  • Source File: 1838434.pdf
  • Pages: 6
  • Description: Professional manual for the CREE LIGHTING Noctura Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Noctura Series LED Flood Lights Small Flood Light 1 of 3 LPN00630X0001A0_C INSTALLATION INSTRUCTIONS INSTRUCTIONS D’INSTALLATION TO INSTALL: 1 SWIVEL KNUCKLE MOUNT- REQUIRES USE OF NTF-KN ACCESSORY STEP 1: Separate the two halves of the swivel knuckle mount by removing the screw holding the knuckle together. See Figure 1. STEP 2: Thread the cord coming from the luminaire through the upper swivel knuckle mount. STEP 3: Remove the two screws on either side of the cord grip on the luminaire housing. Discard screws. STEP 4: Attach the upper swivel knuckle mount to luminaire housing using (2) 1/4-20 screws and lockwashers provided with the swivel knuckle mount. Tighten screws to 72 in-lbs ( 8 N·m). STEP 5: Thread the cord exiting the upper swivel knuckle mount through the lower swivel knuckle mount and out of the nipple at the base of the lower swivel knuckle mount. STEP 6: Reassemble the two halves of the swivel knuckle mount and begin tightening the screw holding the two halves of the swivel knuckle mount together. Do not fully tighten screw. STEP 7: Pass cord through hole in junction box cover or other customer supplied mounting and thread nipple into mount. Use nut on nipple to lock luminaire in position. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER- Risk of shock- Disconnect power before installation. DANGER – Risque de choc – Couper l’alimentation avant l’installation. 2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié. 3. Suitable for wet locations. Convient aux emplacements mouilles 4. Suitable for operation in ambient not exceeding 40°C. Peut etre utilise a une temperature ambiante n’excedant pas 40°C. 5. Suitable for mounting within 1.2M (4ft) of the ground. Peut etre installe a moins de 1,2 m (4 pi) du sol. 6. Min. 75°C supply conductors. Les fils d’alimentation 75°c min. 7. Class 1 wiring only. Cablage de classe 1 uniquement. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE Button Photocell (Ordered Separately) Attach this Part of the Knuckle Mount Arm to Luminaire Head Lower Swivel Knuckle Mount Remove the Screw Here to Separate the Two Halves. Upper Swivel Knuckle Mount Remove the Two Screws at these Locations to Allow for Attachment of Knuckle Mount

CREE LIGHTING Noctura Series Installation instructions manual [PDF] (10 pages)

  • Identifier: id-1884329
  • Brand: CREE LIGHTING
  • Device: Noctura Series Flood Light
  • Type: PDF
  • Key Aspects: Troubleshooting Information, Unpacking and Inspection Guidelines, Control Panel and Interface Navigation
  • UPD Date: 19.08.2026
  • Source File: 1838433.pdf
  • Pages: 10
  • Description: Instruction reference guide for the CREE LIGHTING Noctura Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Noctura Series LED Flood Light Large Flood Light 1 of 5 LPN00630X0002A0_B INSTALLATION INSTRUCTIONS INSTRUCTIONS D’INSTALLATION TO INSTALL: IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER- Risk of shock- Disconnect power before installation. DANGER – Risque de choc – Couper l’alimentation avant l’installation. 2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié. 3. Suitable for wet locations. Convient aux emplacements mouilles 4. Suitable for operation in ambient not exceeding 40°C. Peut etre utilise a une temperature ambiante n’excedant pas 40°C. 5. Suitable for mounting within 1.2M (4ft) of the ground. Peut etre installe a moins de 1,2 m (4 pi) du sol. 6. Min. 75°C supply conductors. Les fils d’alimentation 75°c min. 7. Class 1 wiring only. Cablage de classe 1 uniquement. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE 1 TRUNNION MOUNT- REQUIRES USE OF NTX-TR ACCESSORY STEP 1: Plug the female end of the quick connect, supplied with the trunnion, into the male connector on the luminaire. Make sure the two halves lock together. See Figure 1. STEP 2: Align the four holes in the inner trunnion with the four tapped holes in the luminaire housing. Attach the trunnion to the luminaire using the (4) 5/16" (8 mm) bolts and lockwashers supplied with the trunnion kit. Tighten bolts to 132 in-lbs (15 N·m). See Figure 2. STEP 3: Mount the luminaire in the desired location using (2) 3/8" (10 mm) bolts (customer supplied) appropriate for the mounting surface. See Figure 3. STEP 4: Make wiring connections to the cord leads per the Electrical Connections section. STEP 5: Remove #10-24 positioning screws on both sides of the trunnion. STEP 6: Loosen 5/16" (8 mm) hex head bolts located on both sides of the trunnion. STEP 7: Rotate trunnion to desired tilt angle. Line up inner and outer trunnion positioning holes. STEP 8: Insert one #10-24 screw, removed in Step 5, into matching holes of inner and outer trunnions. Tighten screw to 30 in-lbs (35 N·m). Repeat with screw on opposite side of trunnion. STEP 9: Tighten both 5/16" hex head bolts on opposite sides of the trunnion to 132 in-lbs (15 N·m). 2 3 Female End of Connector Male End of Connector Inner Trunnion #10-24 Screws to Adjust the Orientation For Wall Mounting, Keep the Keyholes Facing Upwards During Installation Outer Trunnion. Fix this on the Mounting Surface (4) 5/16” (8 mm) Bolts Bolts into Keyholes Slots First (2) 5/16" (8 mm) Bolts