Crestron CLCI-MCEX Manuals

1 pdf manual(s) Crestron CLCI-MCEX for free download (Document Types: Installation manual)

Crestron CLCI-MCEX Installation manual [PDF] (2 pages)

  • Identifier: id-1882778
  • Brand: Crestron
  • Device: CLCI-MCEX Controller
  • Type: PDF
  • Key Aspects: Best Practices for Everyday Use, Error Code Explanations, Performance Optimization Tips
  • UPD Date: 17.04.2026
  • Source File: 1839984.pdf
  • Pages: 2
  • Description: Technical reference manual for the Crestron CLCI-MCEX.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
CLCI-MCEX Shutter Motor Controller Installation Guide Description The Crestron® CLCI-MCEX is a motor controller that provides open and close control of one shade or shutter motor. The CLCI-MCEX has outputs for raise/open and lower/close control. Its ultra-slim design allows it to be installed in the ceiling, either next to or near the motor. Powered by infiNET EX® technology, the CLCI-MCEX communicates wirelessly with the control system, making it perfect for both new and retrofit applications. Install an in-line switch to provide local control of the shade or shutter motor. Additional Resources Visit the product page on the Crestron website (www.crestron.com) for additional information and the latest firmware updates. Use a QR reader application on your mobile device to scan the QR image. Important Notes CAUTION: Observe the following points: • Install the CLCI-MCEX only on 10 A branch circuits. • Install using wires that are 1 mm2 to 2.5 mm2 and that comply with IEC 60227-5 and local electrical codes. • Use the CLCI-MCEX with loads that have a power factor of 0.50 or greater. • To meet radiated emissions requirements, ensure that 3 feet (1 meter) of wiring leading to and from the CLCI-MCEX is straight and that there are no loops in the wiring. NOTE: Observe the following points: • Codes: This product must be installed by a licensed electrician and in accordance with all local and national electrical codes. • Wiring: The CLCI-MCEX requires a neutral connection to operate. • Wiring: Use copper wire only. For supply connections, use wires rated at least 75 °C. • Motor Type: For use with a permanently installed motor. • Temperature: For use where temperatures are between 0° and 40 °C (32° and 104 °F). • Transportation and Storage: Transport and store this device when temperatures are between -25° and 60 °C (-13° and 140 °F). • Spacing: If mounting one device above another, leave at least 115 mm (4-1/2 in) vertical space between them. Installation WARNING: To avoid fire, shock, or death, turn off the power at the circuit breaker or fuse and test that the power is off before wiring! Install the CLCI-MCEX: 1. Turn off the power at the main circuit breaker. WARNING: The device should be mounted in a well-ventilated and dry area. 2. Identify the installation location for the CLCI-MCEX. 3. Remove the end caps from the device by unfastening the two screws shown. Unscrew and remove. Unscrew and remove. 4. Loosen the strain relief clamp screw and rotate the clamp to the side for wiring. L N G G N L L R Loosen the screw. (Do NOT remove.) 5. To mount the device (optional), use two M3 X .05 screws (not included). Mounting Screw Locations 6. Wire the device as shown in the illustration in the “Wiring” section. CAUTION: Use with wires that are 1 mm2 to 2.5 mm2. 7. Tuck the wires under the strain relief clamps, and tighten the clamp screws. The jacketed cable must be clamped under the strain relief clamps. Tighten the screws. L N G G N L L R 8. Replace the end caps. 9. With the device still accessible, turn on the main circuit breaker. Wiring WARNING: To avoid fire, shock, or death, turn off the power at the circuit breaker or fuse and test that the power is off before wiring! Wire the CLCI-MCEX and a remote switch. infNET EX communication to control system L N G G N L L R SW2 N SW1 N Remote (brown) AC input from breaker AC to next device Neutral (blue) Live (brown) Live (brown) Neutral (blue) Live (brown) Earth (green/yellow) Earth (green/yellow) 230 VAC maintained or momentary switch To motor SW1 and N to motor open SW2 and N to motor close NOTE: The jacketed cable must be clamped under the clamping bar. Remote Maintained (Single Switch) Live Remote Remote Maintained (Multiway) Live Remote Remote Maintained (Multiway) Live Remote Remote Momentary (Single Switch) Remote Live Remote Momentary (Multiway) Remote Live