Crestron CLTI- Manuals

1 pdf manual(s) Crestron CLTI- for free download (Document Types: Function manual)

Crestron CLTI- Function manual [PDF] (6 pages)

  • Identifier: id-194580
  • Brand: Crestron
  • Device: CLTI- Terminal Block
  • Type: PDF
  • Key Aspects: Standard Operating Procedures, Technical Data and Parameters, Error Code Explanations
  • UPD Date: 30.08.2026
  • Source File: 121950.pdf
  • Pages: 6
  • Description: Reference manual for the Crestron CLTI-.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Crestron CLTI- & CLXI-2DIM8 Terminal Block & Module Functional Summary NOTE: Modules and terminal blocks must be installed into the lowest available spaces and continue toward the top of the enclosure. The Crestron® 2-Feed, 8-Dimmer Terminal Block and Module (CLTI-2DIM8 and CLXI-2DIM8, respectively), are considered a single entity and must be used together. They ship separately to permit termination of the field wiring to the CLTI-2DIM8 prior to installation of the CLXI-2DIM8, as described in this guide. They can be mounted in any Crestron Automation Enclosure (CAEN or CAENIB-Series Enclosures). The terminal block is designed to terminate two circuit feeds (LINE and NEUTRAL) and distribute the controlled circuits (LOAD) to the fixtures. The module connects to the terminal block and performs dimming control of eight incandescent, magnetic low voltage, neon, cold cathode, or dimmable 2-wire fluorescent lighting loads. The maximum load is 10 amps for any single controlled circuit, or 13 amps for each group of four circuits, and 26 amps maximum total per module. The unit requires 230VAC 50 Hz, 1 phase input voltage. An oversize heat sink dissipates heat efficiently. There are LEDs on the module to indicate communication to a Cresnet® network, input power to the module, and output power to the load. Terminal Block & Module Locations (Single-wide Enclosure) MODULE ROUNDING ERMINAL BLOCK TERMINAL BLOCK (INSTALL INTO LOWEST AVAILABLE SPACES) NOTE: The two input lines must be the same phase or split phase. NOTE: When connecting to an Arc Fault Breaker, the load should not exceed 1000 watts. Terminal Block & Module Locations (Double-wide Enclosure) Installation The terminal block and module must be mounted into a Crestron Automation Enclosure by a licensed electrician, in accordance with all national and local codes. CAUTION: This equipment is for indoor use only and needs to be air-cooled. Mount in a well-ventilated area. The ambient temperature must be 0°C to 40°C (32°F to 104°F). The relative humidity must be 0% to 90% (non- condensing). Terminal blocks are installed along the left side of single- wide enclosures and along the outside edges (left and right sides) of double-wide enclosures. Modules are installed along the right side of single-wide enclosures and side-by-side in the center of double-wide enclosures. When installing modules and terminal blocks in a double- wide enclosure, be sure to invert units on the right side so that they can be properly wired. Refer to the illustrations shown in the next column when considering the location of terminal blocks and modules within an enclosure. Crestron Electronics, Inc. Installation Guide – DOC. 6411A 15 Volvo Drive Rockleigh, NJ 07647 (2013809) Tel: 888.CRESTRON 11.07 Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice. MODULE TERMINAL BLOCK (LEFT) GROUNDING TERMINAL BLOCKS TERMINAL BLOCK (RIGHT) (INSTALL INTO LOWEST AVAILABLE SPACES)

CLTI-: Related Instructions

QM-MD5x1
Crestron QM-MD5x1
23.05.2026 72 pages

Crestron QM-MD5x1 QuickMedia™ Matrix Switcher/Mixer Operations Guide User handbook for the Crestron QM-MD5x1 Switch. It provides instructions for troubleshooting tips, firmware installation, operating instructions, compatibility information.

iMedia IM-RX1
Crestron iMedia IM-RX1
10.06.2026 36 pages

Crestron IM-RX1 & IM-RX3 iMedia Receiver/Processor Operations & Installation Guide Product usage guide for the Crestron iMedia IM-RX1 Receiver. It includes maintenance procedures and troubleshooting guides, safety, technical guidelines.

Cameo C2NI-CB Series
Crestron Cameo C2NI-CB Series
06.05.2026 48 pages

Crestron C2N/C2NI-CB Series Cameo® Keypads Operations & Installation Guide Operation guide for the Crestron Cameo C2NI-CB Series Keypad. The guide outlines procedures for setup, troubleshooting, software updates, usage procedures.

DigitalMedia NVX Series
Crestron DigitalMedia NVX Series
11.06.2026 34 pages

DigitalMedia™ NVX Series System Design Guide Crestron Electronics, Inc. Official operating instructions for the Crestron DigitalMedia NVX Series Media Converter. The guide provides instructions on operating guidelines, device operation tips, supported accessories.

C2N-RTHS
Crestron C2N-RTHS
05.07.2026 28 pages

Crestron C2N-RTHS Remote Temperature/Humidity Sensor Operations & Installation Guide Advanced user guide for the Crestron C2N-RTHS Racks & Stands. The manual elaborates on features and shutdown procedures, wiring diagrams, technical specifications, control functions.

CEN-IO-COM-102
Crestron CEN-IO-COM-102
07.05.2026 2 pages

Quick Start The Crestron® CEN-IO-COM-102, CEN-IO-DIGIN-104, CEN- IO-IR-104, and CEN-IO-RY-104 allow for easy expansion of I/O ports within a system. Distribute User operation guide for the Crestron CEN-IO-COM-102 Control Unit. This manual explains maintenance guidelines, replacement parts, shutdown procedures, network setup.

Similar Manuals in the Terminal Block Category

ZERO SCREW EF2 Series
HRS ZERO SCREW EF2 Series
09.05.2026 37 pages

TITLE: EF2 Series Guideline REVISION DATE: 13-Oct.-20 Rev No. 3 HIROSE ELECTRIC CO., LTD. OBJECT PRODUCT: EF2 SERIES Figure No. ETAD-C0387-00 PAGE: 1 OF 36 EF2 Product manual for the HRS ZERO SCREW EF2 Series Industrial Electrical. The manual describes usage recommendations, application scenarios, usage tips.

SCXI-1322
National Instruments SCXI-1322
23.06.2026 12 pages

CVI™, LabVIEW™, and National Instruments™, ni.com™, NI-DAQ™, and SCXI™ are trademarks of National Instruments Corporation. Product and company names Full operation manual for the National Instruments SCXI-1322 Touch terminals. This documentation explains configuration and basic operation, safety, setup instructions, hardware setup.

XpressNet Digital plus LA152
Lenz XpressNet Digital plus LA152
19.08.2026 2 pages

Information LA152 Art. Nr. 80152 3. Auflage / 3rd Edition / 03 03 3e édition Seite / Page: 1 LA152 Art. Nr. 80152 Wozu dient der Adapter LA152? Mit dem Adapter Practical operating guide for the Lenz XpressNet Digital plus LA152 Terminal Block. It provides technical information on product safety, safety features, usage examples.

VTSA-ASI 4E4A-Z Series
Festo VTSA-ASI 4E4A-Z Series
27.04.2026 86 pages

Kurz− beschreibung Brief description MPA−Ventilinsel mit AS−Interface Typ VMPA−ASI− EPL−...−4E4A−Z MPA valve terminal with AS−Interface type V Essential instructions for the Festo VTSA-ASI 4E4A-Z Series Touch terminals. The documentation includes details on network configuration, supported accessories, device features.