D-Link DSN-5110-10 Manuals

5 pdf manual(s) D-Link DSN-5110-10 for free download (Document Types: Cli user's manual, Software user's manual, Datasheet)

Document Preview & Text Transcription

D-Link System, Inc.™ xStack Storage DSN-1000 / 2000 / 3000 / 4000 / 5000 series Command Line Interface User’s Guide Version 1.5 © 2011 D-Link Systems, Inc. All Rights Reserved D-Link Systems, Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. D-Link Systems, Inc. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of D-Link Systems, Inc. The information is provided “as is” without warranty of any kind and is subject to change without notice. The only warranties for D-Link Systems products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. D-Link Systems shall not be liable for technical or editorial errors or omissions contained herein. Copyright © 2011 D-Link Systems, Inc.™ Trademarks xStack is a registered trademark of D-Link, Inc. Adobe® and Acrobat® are trademarks of Adobe Systems, Incorporated. Java™ is a U.S. trademark of Sun Microsystems, Incorporated. Microsoft Windows is a U.S. registered trademarks of Microsoft Corporation. Oracle® is a registered U.S. trademark of Oracle Corporation, Redwood City, California. UNIX® is a registered trademark of The Open Group. All other brand or product names are or may be trademarks or service marks, and are used to identify products or services, of their respective owners. D-Link Systems, Inc. 17595 Mount Herrmann Street Fountain Valley, CA 92708 www.DLink.com Command Line Interface User’s Guide iii Notice of Export Controls Export of technical data contained in this document may require an export license from the United States government. Please contact D-Link, Inc. for any export compliance questions. Document Revision Level Date Description July 2008 Version 1.0 September 2008 Version 1.1 – updated for software version 2.5.0 and redundant controllers January 2009 Version 1.2 – minor technical and formatting updates May 2009 Version 1.3 – updated for software version 2.6.0 December 2009 Version 1.4 – updated for software version 2.7.0, including new commands for SNMP support, revised syntax for the IntegrityScanNow command, and several new Volume attributes October 2010 Version 1.5 – updated for software version 2.8.0, including several new commands in the AdvancedSettings context and removal of the IsBatteryFailed and IsBatteryCharging items from the System context

Document Preview & Text Transcription

D-Link xStack Storage iSCSI SAN Arrays Managed SAN Solutions (DSN-1100-10, 2100-10, 3200-10, 3400-10, DSN-4100, DSN-4200, DSN- 4000, 5110-10, 5210-10, 5410-10, 5000-10) Management Center Software User’s Guide Version 1.4 ii Contents © 2010 D-Link Systems, Inc. All Rights Reserved D-Link Systems, Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. D-Link Systems, Inc. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of D-Link Systems, Inc. The information is provided “as is” without warranty of any kind and is subject to change without notice. The only warranties for D-Link products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. D-Link shall not be liable for technical or editorial errors or omissions contained herein. Copyright © 2010 D-Link Systems, Inc.™ Trademarks Includes one or more of the following United States patents: 6,941,396; 7,353,306; 7,389,462; 7,460,473; 7,512,663 and 7,594,002. Other patents pending. D-Link and the D-Link logo are registered trademarks of D-Link, Inc. Java™ is a U.S. trademark of Sun Microsystems, Incorporated. Microsoft Windows is a U.S. registered trademark of Microsoft Corporation.. All other brand or product names are or may be trademarks or service marks, and are used to identify products or services, of their respective owners. D-Link Systems, Inc. 17595 Mount Herrmann Street Fountain Valley, CA 92708 USA xStack Storage Management Center Software User’s Guide iii Notice of Export Controls Export of technical data contained in this document may require an export license from the United States government. Please contact D-Link, Inc. for any export compliance questions. Document Revision Level Revision Date Description 1.0 July 2008 Version 1.0 – Initial release based on Software version 2.0.0 1.1 September 2008 Version 1.1 – Updated for software version 2.5.0 and redundant controller support 1.2 January 2009 Version 1.2 – Updated for software version 2.5.1 and minor formatting corrections 1.3 May 2010 Version 1.3 – Updated for software version 2.7.0 and added more summary information to Chapter 1 1.4 July 2010 Version 1.4 – Updated for software version 2.8.0
D-Link DSN-5110-10 Datasheet Main Page Preview

Datasheet [PDF] (5 pages)

  • Updated: 01.04.2026

Document Preview & Text Transcription

b u s i n e s s DSN-5000 Series iSCSI SAN Array xStack Storage® HA capable 4x1GbE, 8x1GbE or 1x10GbE iSCSI SAN Array with 12 SAS/SATA1 Bays (expandable to 84 bays) Affordable Data Center Class Storage • High Availability (HA) Capable • Handles Over 80,000 I/Os per Second • Battery Protected Cache Memory: DSN-5110-10: 1GB per controller DSN-5210-10: 2GB per controller DSN-5410-10: 2GB per controller • System Memory: 512MB • 12 Hot-Swap SAS/SATA1 Hard Drive Bays • Supports 24TB Capacity with 2TB Hard Drives • Supports up to 1024 volumes and host connections • RAID Support: 0, 1, 1+0, and 5 • Mix and Match disk drives within a single array • Different Capacities, Manufacturers, Technologies and Speeds • Volume Virtualization technology • Supports multiple RAID types and volumes segments on single drive • Optimizes capacity utilization and maximizes performance • Supports Online Capacity Expansion, Volume Reconfiguration and Migration on the fly • Drive Roaming supported in Power Off • Additional DSN-5000-10 Expansion Arrays Provide: DSN-5110-10: 96TB Total Capacity DSN-5210-10: 168TB Total Capacity DSN-5410-10: 168TB Total Capacity • 430 Watt Dual Redundant Hot-Swappable Power Supplies • Industry Standard 2U 19-inch Chassis High Performance iSCSI Interface • DSN-5110-10: Four 1GbE Ports per controller • DSN-5210-10: Eight 1GbE Ports per controller • DSN-5410-10: One 10GbE Port per controller Overview D-Link’s DSN-5000 series (DSN-5110-10, DSN-5210-10 and DSN-5410-10) iSCSI SAN array is a highly available, data center-class network storage solution in a 2U rackmount form factor, ideal for small to medium enterprises. The heart of the DSN-5000 series is a powerful 10Gbit iSCSI System-on-a-Chip (SoC) capable of handling over 80,000 I/Os per second. The DSN-5000 series supports 24TB of raw capacity using 2TB drives and overall scalability to 168TB (DSN-5210-10 and DSN-5410-10). The DSN-5000 series can be easily implemented as a supplemental backup platform for quick restores, as secondary online storage, or as bandwidth-demanding primary storage for security surveillance and A/V applications. A Choice of Host Interfaces – 1GbE or 10GbE The DSN-5110-10 and DSN-5210-10 both support Multi-path I/O (MPIO), Multiple Connections per Session (MCS), and Link Aggregation Groups (LAG) for unmatched network flexibility, performance and resiliency, allowing their 1GbE data ports to be grouped together for up to 425MB/s or 850MB/s bandwidth, respectively. The DSN-5410-10 utilizes a built-in, fully integrated 10GbE interface as a high performance alternative to 8Gbps Fibre Channel, for up to 1160MB/s bandwidth. High Availability (HA) The DSN-5110-10, DSN-5210-10 and DSN-5410-10 primary arrays, based on a single controller, each provide an ideal platform for nearline storage requirements such as disk-to-disk backup, data archiving and video surveillance. With the addition of a secondary controller (DSN-510 for the DSN-5110-10, DSN-520 for the DSN-5210-10 and DSN-540 for the DSN-5410-10) the DSN-5000 series can provide the failover and redundancy capabilities required for mission critical scenarios such as Virtual Machine (VM) shares, database applications, Online Transactional Processing (OLTP), email applications, storage consolidation and your other primary storage needs. Expansion Options The DSN-5110-10, DSN-5210-10 and DSN-5410-10 primary arrays each support 12 internal SAS/SATA1 hard drives and with the addition of up to three DSN-5000-10 expansion arrays for the DSN-5110-10, and up to six DSN-5000-10 expansion arrays for the DSN-5210-10 and DSN-5410-10, can scale to a total of 96TB and 168TB raw storage capacity respectively. For high availability operation, a secondary I/O board, DSN-500, is installed in the DSN-5000-10 expansion array. iSCSI for IP Networks Storage Area Networks (SANs) have traditionally been reserved for complex Fibre Channel networks. The recent introduction of iSCSI has extended the powerful centralized storage capabilities of SAN technology to IP networks. By utilizing existing Ethernet technology, the costs associated with Fibre Channel switching, separate host bus adapters, expensive storage subsystems and administration is significantly reduced. iSCSI SANs leverage the Ethernet infrastructure and standards that are already familiar to most IT personnel. System-on-a-Chip (SoC) Implementation By utilizing a SoC design, the DSN-5000 series combines both networking and storage functions into a single specialized Application Specific Integrated Circuit (ASIC). This SoC combines 10Gbps iSCSI, TCP & IP offload, 12 embedded processors and storage virtualization firmware onto a single chip. The tight integration of these functions eliminates interoperability, timing and support issues found in competitive products b u s i n e s s DSN-5000 Series iSCSI SAN Array that offer a “discrete implementation” where in various components are selected separately, then assembled. RAID support D-Link’s xStack iSCSI SAN arrays support RAID levels 0, 1, 1+0 and 5 configurations (striped sets, mirrored sets, striped mirrored sets and parity sets) for data protection and performance. D-Link supports S.M.A.R.T., disk scan, and non- destructive data migration to prevent disk failure. Embedded Centralized Storage Management All of the D-Link xStack Storage products share a common easy-to-use configuration and management GUI console that allows you to manage multiple units from a single screen. The intuitive wizards ensure you will have your SAN out of the box and ready to go in a few minutes. The embedded, user-friendly IP-SAN Device Manager (IDM) provides a comprehensive console for system management. Boasting a rich set of management features, this suite of utilities allows monitoring and control of the SAN array via the Storage Management Initiative-Specification (SMI-S) command set. With a secure server, users can remotely configure and monitor their SAN arrays over the Internet. Advanced Management Features The DSN-5000 series also provides an advanced set of features for efficient management and optimal storage performance. For the fastest RAID performance offered in the industry, D-Link’s adaptive cache management provides write coalescing and multi-stream read-ahead on a volume basis, optimizing cache utilization and performance in an application-dependent manner. Volatile cache data protection is afforded via an on-board battery supporting 2GB of cache memory for a minimum of 72 hours. A write-back or write-through cache memory policy can be selected manually or automatically, depending on the status of the battery’s charge. The DSN-5000 series supports jumbo frames and VLAN tagging to segregate traffic into isolated zones for secure access, improving network throughput and reducing CPU overhead. D-Link’s volume virtualization technology utilizes the concept of storage extents, which are the fundamental building blocks used to enable features such as RAID, online capacity expansion, volume reconfiguration and migration. Each disk drive can contain multiple and divergent RAID configurations instead of requiring dedication to a single RAID set. This technology allows for the support of mixed disk drive capacities for volume creation. Volume capacity expansion and RAID level migration are performed online with minimal impact to users. Additionally, volume growth can occur without volume migration or reconstruction. Users can quickly deploy a SAN and simply add more drives as needed. An iSCSI SAN array can prove to be a valuable tool to supplement a network storage foundation. Whether providing a low-cost block-based solution for replacement of Direct Attached Storage (DAS), providing primary online storage, or providing up to 1160 MB/s bandwidth for security surveillance, video editing, video post-production applications, the DSN-5000 series will provide the performance and functionality needed. High Availability (HA) • DSN-510 - Four 1GbE Ports (Secondary controller for DSN-5110-10) • DSN-520 - Eight 1GbE Ports (Secondary controller for DSN-5210-10) • DSN-540 - One 10GbE Port (Secondary controller for DSN-5410-10) Drive Expansion • DSN-5000-10 Expansion Array • For use with DSN-5110-10, DSN-5210-10 and DSN-5410-10 Primary SAN Arrays • Provides 12 Hot-Swap Drive Bays • Up to six expansion arrays supported for 84 drives total (DSN-5210-10 and DSN-541) xStack Storage® HA capable 4x1GbE, 8x1GbE or 1x10GbE iSCSI SAN Array with 12 SAS/SATA1 Bays (expandable to 84 bays) b u s i n e s s DSN-5000 Series iSCSI SAN Array Technical Specifications DSN-5110-10 • Four 1GbE Copper per controller DSN-5210-10 • Eight 1GbE Copper per controller DSN-5410-10 • One 10GbE per controller (XFP adapter sold separately) Features Drive Bays • 12, Expanadable with DSN-5000-10 Expansion Arrays to - 48 for the DSN-5110-10 - 84 for the DSN-5210-10 and DSN-5410-10 Drive Interface Support SAS/SATA1 System Memory 512MB Cache Memory • DSN-5110-10: 1GB per controller • DSN-5210-10: 2GB per controller • DSN-5410-10: 2GB per controller Battery Backup for Cache • Standard (Approximately 72 hours on full charge) Bandwidth • DSN-5110-10: Up to 425MB/s • DSN-5210-10: Up to 850MB/s • DSN-5410-10: Up to 1,160MB/s Storage Capacity • 24TB Capacity with 2TB Hard Drives • Additional DSN-5000-10 Expansion Arrays Provide - DSN-5110-10: 96TB Total Capacity - DSN-5210-10: 168TB Total Capacity - DSN-5410-10: 168TB Total Capacity Operating Systems Supported Please see support.dlink.com for latest support information • Windows Vista® 32-bit & x64 (Ultimate & Enterprise) w/Built-in iSCSI initiator • Windows Server® 2003 R2 | SP1 32 & 64-bit (Standard & Enterprise) with v2.07 iSCSI initiator or later • Windows Server 2008 Enterprise 32 & 64-bit with Built-in iSCSI initiator • Windows XP Pro® 32 & 64-bit with v2.07 iSCSI initiator or later • Windows 2000 Advanced Server – No MS iSCSI Initiator support, Qlogic HBA only • Red Hat® 7.3 • Red Hat Enterprise AS update 5 (64-bit) • Red Hat Enterprise 5 update 2 (64-bit) • SuSE® Professional 9.3 32-bit • SuSE Enterprise Server 10.2 32-bit • Sun Solaris® 10 build 6/06 • IBM AIX 5L • Microsoft Hyper-V • VMWare ESX Server® 3.02 & 3.5 • VMWare ESX Server 4.0 • Virtual Iron v4.2 • Citrix XenServer® v4 • Mac OS X® (10.4 & 10.5) Supported NICs, iSCSI Accelerators and iSCSI HBAs Please see support.dlink.com for latest support information • Intel® Pro 1000MT & XT [1GbE] • Intel Pro 10000 CX4 [10GbE] • Myricom® 10G-PCIE-8A-C+E [10GbE] • Chelsio S310X-SR-XFP [10GbE] • Neterion® Xframe® II & Xframe E [10GbE] • Alacritech® SES2104ET (Drivers: SNP 9.1.0.1092 & 7.3.1.0) • Alacritech SES2102ET (Drivers: SNP 9.1.0.1092 & 7.3.1.0) • QLogic® 4010C, 4052C, & 4062C iSCSI Network Interface Host Interface • iSCSI Draft 20 Compliant Initiator Connections • 1,024 Hosts CHAP Authentication • Yes

Document Preview & Text Transcription

Page 1 DSN-5xx0 (5110-10, 5210-10, 5410-10) - 5/2010 Copyright © 2010 D-Link, Inc. - All Rights Reserved P R I M A R Y A R R A Y DSN-5xx0-10 Primary Array Quick Start Guide The DSN-5xx0 Primary Array Quick Start Guide provides the information needed to get your DSN-5xx0-10 primary array out of the box and operational with a connection to a host computer. Follow the simple instructions in this guide, and in no time at all you will be part of the iSCSI revolution. Important Safety Information: Before you install the DSN-5xx0-10 primary array, please read all documentation provided on the Product CD. The DSN-5xx0-10 primary array is available in either single or dual controller configurations. The dual-controller systems offer automatic failover capability for High Availability in the event of a controller failure. Each controller can have either four (DSN-5110-10 and DSN-510) or eight (DSN-5210-10 and DSN-520) 1-GbE data ports or one (DSN-5410-10) 10-GbE data port in each controller for iSCSI communication. Each controller comes with 512 MB of system memory and 1 GB (DSN-5110-10 and DSN-510) or 2 GB (DSN-5210, DSN-520, DSN- 5410-10, DSN-540) of buffer memory. The DSN-5xx0-10 primary array can support a total of 4 GB of buffer memory. For systems with two controllers, both controllers must have the same number and type of data ports, the same amount of Buffer Memory, and the same version of software. 1 Unpack the Package Contents Before unpacking, inspect the container for damage. If damage exists, file a claim with the carrier. Remove the items from the container and compare them to the packing list:  One DSN-5xx0-10 primary array (includes backplane, up to 12 drive carriers with drive blanks, two power supplies, 48 drive carrier screws holding drive blanks, and one canister filler plate)  One controller with memory and battery in canisters, inserted into the rear of the DSN-5xx0-10 primary array.  One rack-mount kit in a box (includes rails, mounting hardware, and instructions)  Six power cords, one RS-232 diagnostic cable, one DSN-5000 Series Product CD.  One set of packing materials and cartons If contents are missing or damaged please contact your supplier. Save all packing materials in case you have to return the unit. 2 What Else You Need To complete the primary array installation, you need:  A computer that will act as the iSCSI initiator (see step 7). Please refer to the D-Link Interoperability matrix at: http://www.dlink.com for tested operating systems, Network Interface Cards (NICs), Host Bus Adapters (HBAs), and network infrastructure.  A static IP address and Category 6 or 5E (for 1-GbE) or fiber optical (for 10-GbE) network cable for each DSN-5xx0 primary array data port that will connect to your SAN.  XFP modules for optical connection (10-GbE systems only)  Ethernet switch (1-GbE for DSN-5110-10 & DSN-5210-10, or 10- GbE for DSN-5410-10) required for dual-controller systems  Independent AC power supply within 6 feet of the primary array  Disk drives: refer to the DSN-5000 Series Hardware Reference Guide for disk drive installation  Note: The DSN-5xx0-10 primary array can support SAS or SATA hard disk drives from a variety of manufacturers (48 for the DSN- 5110-10 and 84 for the DSN-5210-10 & 5410-10). It is possible (but not recommended) to mix SAS and SATA drives in the same array. Also, if you anticipate using dual controllers for HA operation, SAS drives are required.  Optional: In addition, a separate computer may be used as the Management console (see Step 8)  Optional, but recommended: Uninterruptible power supply 3 Rack-Mount Instructions The DSN-5xx0-10 primary array can be mounted in a standard 19-inch rack using the rack-mount kit provided with the DSN- 5xx0 primary array. Note: The rack cabinet must provide sufficient airflow to the front and rear of the DSN-5xx0-10 primary array for correct cooling. Ventilation must be sufficient to exhaust heat from the rear of the equipment in the rack. Plan the rack installation with the heaviest item on the bottom of rack. A. Ensure that power is not being applied to the DSN-5xx0 primary array by removing the power cords before attaching the mounting hardware provided to the left and right sides of the rack supporting the DSN-5xx0-10 primary array. B. With the help of another person, slide the DSN-5xx0-10 primary array into place (without drives installed) and secure with the mounting hardware. 4 Install the DSN-5xx0-10 Primary Array The DSN-5xx0-10 primary array is a full iSCSI storage subsystem, with up to 12 SATA or SAS disks, and additional storage available through add-on expansion arrays. Enclosure and drive carrier LEDs illuminate on the front of the unit, while interface ports, buttons, and LEDs for port speed, port activity, and status are at the rear. Note: Be sure that empty drive carriers are replaced by drive blanks in all drive slots that are not occupied by a drive. Rear View (DSN-5210-10 shown) Four or Eight 1-GbE iSCSI Data Ports Rear Panel Status LEDs and Switches Two Expansion Ports One Management Port Front View Enclosure LEDs Drive Carrier LEDs Drive Carrier Primary Controller in Slot #0 Redundant Controller or Filler Plate in Slot #1 s Page 2 Contact Information For more information about the DSN-5xx0-10 Primary Array Web site: http://www.dlink.com/ No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or stored in a database or retrieval system, without the expressed written approval of D-Link, Inc. D-Link reserves the right to make changes to this document at any time without notice and assumes no responsibility for its use. This document contains the most current information available at the time of publication. However, all of the features described in this document may not be currently available. 5 Connect to the DSN-5xx0-10 Primary Array Identifying the Data and Management Ports A. Attach an Ethernet cable to the iSCSI 0 data port on the primary controller of the DSN-5xx0-10 primary array rear panel and to your SAN switch. To connect additional data ports to your SAN, repeat this step using another Ethernet cable and the next data port, up to the number of data ports on the controller. If you have dual controllers, repeat this step for the redundant controller. B. On the rear of each controller of the DSN-5xx0-10 primary array, the management port is the 10/100/1000 RJ-45 port labeled MGMT. If you have dual controllers, you must connect the management port of both controllers to your network switch. If you have a single controller, you can directly connect this port to your Management Host using a standard Ethernet cable for a GbE host port or a crossover cable for a 10/100 host port. Out of the box, the active management port defaults to the IP address 192.168.1.1. This can be changed using the Start-up Wizard. C. The diagnostic port (stereo jack) labeled DIAG is used for diagnostic purposes only. If needed, use the supplied RS-232 cable to connect this port to a computer serial port configured for a baud rate of 115,200 bps at 8 data bits, no parity bit, and 1 stop bit. 6 Prepare Your Server This guide assumes that Microsoft Windows 2003 Server or later will be used for product set up. Other operating systems are supported (see step 2), but in this guide, Microsoft Windows 2003 Server will be used. The server must have a 10/100/1000 Gbps NIC. All updates, Service Packs, and drivers for the operating system and NIC must be installed. If your server uses the NIC for iSCSI storage access, install the latest supported version of the Microsoft iSCSI initiator software at: http://www.microsoft.com/downloads. Connecting the iSCSI Data Port(s) and Management Port 7 Prepare the Management Host A. The management port on the primary controller of the DSN-5xx0 primary array has an IP address of 192.168.1.1. Therefore, to start with, the NIC must have a fixed IP address of 192.168.1.n (e.g., 192.168.1.2). After you set up the DSN- 5xx0 primary array via the Start-Up Wizard, the management port can be changed to the desired IP address (for example, to use on your corporate LAN). B. Download Java Runtime Environment 6 (JRE 6), v1.6.0.0 or later. That software is available at: http://java.com. Note: Attempting to install the Java Runtime Environment 6 on a non-supported version of Windows or a computer whose Service Packs are out of date will display an error message. 8 First-Time Startup A. Plug the two power cords into the AC source (for best practices, the second power receptacle should be on a different circuit). B. Power up the primary array by turning on both rocker switches on both power supplies at the rear of the unit. The system starts to boot:  The Power LED on the rear panel of each controller turns solid green when power is applied.  The DSN-5xx0-10 primary array goes through its power-on procedure, which takes up to 5 minutes, after which the READY LED on the right front rack-mounting bracket turns green. C. On the management computer, point your Web browser to the following default IP address: 192.168.1.1 D. When the Start-up Wizard’s Welcome screen appears, click on the “I Accept the End User License Agreement” button. E. At the Administrator Account screen, enter a case-sensitive password for the administrator account, if you wish to change the default value. The default username is admin and the default password is admin. Click Next. F. At the Management Port screen, enter the IP address, subnet mask, and default gateway that computers will use to access the management port. Change the host name if desired. Click Next. G. At the Data Port screen, enter the IP address, subnet mask, and default gateway for each iSCSI data port. You can skip any or all of these items, and assign them later. Click Next. H. At the Email Notification screen, enable email notifications. Enter an SMTP server IP address and port number, return email address, and email address where alerts are to be sent. If desired, you can skip these items and enter them later. Click Next. I. Review your settings. Use the Back button to change any settings that need to be edited. Then click Finish and wait for the system to restart. You are now ready to use your DSN-5xx0-10 primary array. Note: For more information about the Start-up Wizard or setting the system date and time, please see the DSN-5000 Software User’s Guide. 9 Configure the DSN-5xx0-10 Primary Array To configure the DSN-5xx0-10 primary array after the first-time startup, wait for the system to reboot (up to 5 minutes, System Ready LED goes ON), then start your Web browser to match the IP address identified in step 8F above (default is 192.168.1.1). When the browser connects and the GUI is operational, the Login Screen appears and you are ready to connect to the iSCSI world. Enter your Administrative username and password, then select System Administration from the View Panel, select the Settings tab and select System Policy to ensure that the proper battery and system failure policies are defined for your system. If your DSN-5xx0-10 primary array is equipped with dual controllers, you can verify your network cabling for automatic controller failover by selecting the “Force System Failover” item from the System Actions panel. For more detailed information, please see the DSN-5000 Software User’s Guide. Management Port Data Ports iSCSI 0-7 (DSN-5210-10 systems) or Data Ports iSCSI 0-3 (DSN-5110-10 systems) Data Port iSCSI 0 (DSN-5410-10 systems) DSN-5410-10 DSN-5210-10 & DSN-5110-10 P R I M A R Y A R R A Y Network Switch To Host Servers

Document Preview & Text Transcription

xStack Storage TM D-Link xStack Storage iSCSI SAN Array Managed SAN Solution DSN-5110-10, 5210-10, 5410-10 & 5000-10 Hardware Reference Guide Version 1.4 ii © 2010 D-Link Networks, Inc. All Rights Reserved D-Link Systems, Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. D-Link Systems, Inc. shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of D-Link Systems, Inc. The information is provided “as is” without warranty of any kind and is subject to change without notice. The only warranties for D-Link products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. D-Link shall not be liable for technical or editorial errors or omissions contained herein. Copyright © 2010 D-Link Systems, Inc.™ Patents and Trademarks Includes one or more of the following United States patents: 6,941,396; 7,353,306; 7,389,462; 7,460,473; 7,512,663 and 7,594,002. Other patents pending. The D-Link logo is a registered trademark of D-Link, Inc. Adobe® and Acrobat® are trademarks of Adobe Systems, Incorporated. Java™ is a U.S. trademark of Sun Microsystems, Incorporated. Microsoft Windows is a U.S. registered trademark of Microsoft Corporation. Oracle® is a registered U.S. trademark of Oracle Corporation, Redwood City, California. UNIX® is a registered trademark of The Open Group. All other brand or product names are or may be trademarks or service marks, and are used to identify products or services, of their respective owners. D-Link Systems, Inc. 17595 Mount Herrmann Street Fountain Valley, CA 92708 DSN-5000 series Hardware Reference Guide iii Safety Information There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery pack only with the same or equivalent type recommended by the manufacturer. Do not dispose of the battery along with household waste. Contact your local waste disposal agency for the address of the nearest battery deposit site. This product also uses a lithium coin cell battery. The lithium coin cell battery is a long-life battery, and it is very possible that you will never need to replace it. However, should you need to replace it, consult your service documentation. Do not dispose of the battery along with household waste. Contact your local waste disposal agency for the address of the nearest battery deposit site. CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. The iS512-10G product requires usage of laser transceivers (SFPs) to be installed. Such installation of any installed SFP must comply with the following: 1. The SFP to be installed must be UL Recognized as I.T.E. 2. The Laser Class of the SFP to be installed must be Class 1. 3. The transceivers of the SFP to be installed must comply with U.S. Code of Federal Regulations, 21 CFR 1040. 4. Those transceivers of the SFP to be installed must conform to the applicable requirements of 21 CFR Subchapter J. Following are the safety agency certifications that the xStack Storage enclosure has met: CSA 60950-1 UL 60950-1 IEC 60950-1 EN 60950-1 Compliance Information FCC Class A CE Class A C-Tick Class A VCCI Class A