Daikin BYCQ140CGW1 Manuals

1 pdf manual(s) Daikin BYCQ140CGW1 for free download (Document Types: Installation manual)

Document Preview & Text Transcription

Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel INSTALLATION MANUAL English Installation manual Self Cleaning decoration panel BYCQ140CGW1 1 English BYCQ140CGW1 Self Cleaning decoration panel Installation manual CONTENTS 1. SAFETY PRECAUTIONS ..........................................................1 2. ACCESSORY.............................................................................1 3. INSTALLATION SITE .................................................................2 4. PREPARATIONS FOR PANEL...................................................3 5. PREPARATIONS FOR INDOOR UNIT ......................................4 6. ATTACHING PANEL TO INDOOR UNIT ....................................5 7. ATTACHING SUCTION GRILLE AND DECORATION CORNER COVERS ..................................7 8. OPERATION MODE SETTINGS .............................................10 9. FIELD SETTINGS ....................................................................10 10. TEST OPERATION ..................................................................10 SAFETY PRECAUTIONS 1. Please read these “SAFETY PRECAUTIONS” carefully before installing air conditioning equipment and be sure to install it correctly. After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air condi- tioner and take care of it with the aid of the operation manual. Ask the customer to store the installation manual along with the operation manual for future reference. This air conditioner comes under the term “appliances not accessible to the general public”. Meaning of WARNING and CAUTION notices. WARNING Failure to follow these instructions properly may result in personal injury or loss of life. CAUTION Failure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances. WARNING • Ask your dealer or qualifi ed personnel to carry out installation work. Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fi re. • Perform installation work in accordance with the instructions in this installation manual. Do not modify the product. Improper installation may result in water leakage, electric shocks, or fi re. • Be sure to use only the specifi ed accessories and parts for installation work. Failure to use the specifi ed parts may result in the unit falling, water leakage, electric shocks or fi re. • Make sure that specifi ed wires are used and that there is no strain on the terminal connections or wires. Improper connections or securing of wires may result in abnormal heat radiation or fi re. • Be sure to switch off the unit before touching any electrical parts. • Arrange the lead wires of the provided harness so that the EL. COMPO. BOX lid of the indoor unit will not rise, and attach the lid securely. Heat radiation, electric shocks, or fi re may result if the EL. COMPO. BOX lid is not attached properly. • Tear up and dispose of the plastic bag. Children playing with the plastic bag may be suffocated. CAUTION • Install the indoor and outdoor units, power cord, remote controller wiring, and transmission wiring at least 1m away from TV or radio sets. This is for the prevention of TV and radio interference. (Depending on the incoming signal strength, a distance of 1 meter may not be suffi cient to eliminate noise.) • Pay the utmost attention to the transportation of the product. Hold the handles on the package to carry the product. Do not carry the package with the polypropylene band on the package held, which will be dangerous because the polypropyl- ene band may be deformed. • Do not touch the fi n of the heat exchanger. Touching the fi n improperly may result in injury. • Do not turn the product power off immediately after the operation of the product comes to a stop. Always wait for at least 5 minutes before turning the product power off. Otherwise, water leakage and malfunctions may result. • Do not install the air conditioner in the following locations: 1. Where there is a high concentration of mineral oil spray or vapour (e.g. a kitchen). Plastic parts will deteriorate, parts may fall off and water leakage could result. 2. Where corrosive gas, such as sulphurous acid gas, is produced. Corroding of copper pipes or soldered parts may result in refrigerant leakage. 3. Near machinery emitting electromagnetic radiation. Electromagnetic radiation may disturb the operation of the control system and result in a malfunction of the unit. 4. Where fl ammable gas may leak, where there is carbon fi bre or ignitable dust suspensions in the air, or where volatile fl ammables such as paint thinner or gasoline are handled. Operating the unit in such conditions may result in fi re. [Instructions peculiar to this product] Do not install the product in the following places. Oil, cigarette tar, and steam will result in sticky dust on the fi lter, which may not be cleaned properly. Furthermore, sticky dust may cause malfunctions. Places with oily smoke: Restaurants, factories, etc. Places with excessive cigarette smoke: Smoking room, etc. Places with excessive moisture or steam: Restaurants, factories, etc. • The air conditioner is not intended for use in a potentially explosive atmosphere. Note • Have the customer actually operate the air conditioner while referring to the operation manual and explain the right operation of the air conditioner with useful tips given. • Refer to the operation manual along with the installation manual provided with the indoor unit. Use the BRC1E51A7 remote controller. • ACCESSORY 2. Check that the following accessories provided with the air condi- tioner are correct in number. See the following illustration, which shows where the accessories are kept. Backside of the protective corrugated cardboard A set of accessories The accessories are on the backside of the protective corrugated cardboard under the suction grille. Suction grille English 2 Name Spacer (1) Flexible hose (2) S-shaped pipe (3) Harness (4) Clamp (5) Quantity 1 pc. 1 pc. 1 pc. 1 pc. 1 pc. Shape Name Connecting pipe (6) Attachment (7) Seal (8) Others Quantity 1 pc. 1 pc. 1 pc. Shape • Operation manual • Installation manual Pay the utmost attention to the following items when conduct- ing installation work, and recheck the items on completion of the work. a. Test items on completion of work Test items In case of failure Result Is the air conditioner free of wiring and connection mistakes or omissions? Operation failure and wire burnout Are you sure that there is no space between the ceiling and ceiling material? Water leakage Are the fi xing knobs (in two points) of the dust box secured tightly? Vibration, noise, and dust collection failure Are the fi xed knobs (in fi ve points) of the air fi lter secured tightly? Vibration, noise, and dust collection failure Is the fall prevention cord for the dust box and grille hooked to the mounting bracket? Fall Did you attach the EL. COMPO. BOX lid, dust box, fl exible hose, S-shaped pipe, suction grille, and decoration corner covers? Noise and dust collection failure * Be sure to recheck the items provided in the section “SAFETY PRECAUTIONS”. b. Test items before delivery Test items Result Was the test operation of the air conditioner fi nished? Did you explain the operation method of the air condi- tioner to the customer while showing the customer the operation manual? * Did you make mode settings for fi lter auto cleaning (automatic control operation settings or timer operation settings with an operation time zone specifi ed) and provide information on the set mode operation of the air conditioner to the customer? Did you deliver the operation manual to the customer? (Be sure to hand the customer the operation manual as well as the installation manual.) Did you hand the customer the connecting pipe and attachment and ask the customer to keep them? * Point of operation explanation In addition to the general usage of the air conditioner, it is necessary to explain the descriptions of the WARNING and CAUTION marked items in the operation manual and have the customer read the descriptions carefully, because these items indicate information that, if not heeded, is likely to result in loss of life, serious injury, or property damage. INSTALLATION SITE 3. This product offers selectable air outlet directions. A closure kit (an optional accessory) is required to achieve three-way fl ow patterns. Two-way fl ow patterns are not available to this product. 3-1 Select the installation site that meets the following conditions with the consent of the customer. • The surface of the ceiling is not remarkably inclined. • Installation and service workspace is secured (see the following illustrations). • The panel indicators are seen with ease. • The indoor and outdoor units, power cord, transmission wiring, and remote controller wiring are at least 1m away from TV or radio sets. (The above is for the prevention of TV and radio interference. Depending on the incoming signal strength, a distance of 1 meter may not be suffi cient to eliminate noise.) Required installation space. 3-2 Install the indoor unit according to the installation manual and the following illustrations. Indicator Dust collection inlet Front side of panel Exhaust opening on panel (see note 3) Indoor unit 10° Dust collection inlet 10° 256 Drain socket See note 1 *At least 2,000mm away from the wall (see note 2) (see note 3) Indoor unit Exhaust opening on panel Do not block this part with insulation material. Note 1. A space is required for dust collection with a vacuum cleaner used. 2. The asterisk-marked space will be at least 700mm with the air outlet closed. 3. Do not block the exhaust opening or periphery with insulation material. Otherwise, a malfunction may result. 3 English Mounting directions of suction grille. 3-3 Select one of the following mounting directions of the suction grille on the panel. Piping Piping Drain socket Dust collection inlet Drain socket Suction grille PREPARATIONS FOR PANEL 4. Note • Perform all the required work in “4. PREPARATIONS FOR PANEL” with the panel kept in the packing material (on the bottom side). • Do not put the panel downward or upright or leave the panel on protruding parts. Otherwise, scratch damage to the surface of the panel may result. 4-1 Removal of suction grille from panel, protective corrugated cardboard, and set of accessories. Press the knobs of the suction grille and lift up the knobs. (1) Decoration panel Knobs Packing material (bottom) Suction grille (2) Open the suction grille to an angle of approximately 45° and remove the suction grille from the panel. 45° (3) Take out the protective corrugated cardboard. Take out the protective corrugated cardboard (on top of the panel) together with the accessories attached to the backside of the protective corrugated cardboard. Protective corrugated cardboard (top) (The accessories are on the backside.) Protective corrugated cardboard (bottom) Note Do not impose force on the swing fl ap, brush unit, or air fi lter when handling the panel. Panel Brush unit Air filter Swing flap Removal of decoration corner covers. 4-2 Panel Decoration corner cover Decoration corner cover Decoration corner cover Decoration corner cover (with display) (1) Raise and remove the decoration corner cover (with the display) in the direction of the arrow. Note Do not impose force on the lead wires. Operation/filter cleaning (2) Remove the screws on the backside of the decoration corner cover (with the display), open the cover, and remove the connector attached to the front end of the lead wires from the PCB. Cover Connector Lead wires PCB 3 1 Screw 2 Decoration corner cover (with display) (3) Remove each of the remaining decoration corner covers (i.e., three covers) in the direction of the arrow. Panel Decoration corner cover Removal of dust box. 4-3 Fixing knob of dust box and clasp Dust box Fixing knob of dust box